NASA NTRS ยท 19770017440
Transformer design tradeoffs
Abstract
In space, power system transformer components are frequently the heaviest and bulkiest items in the power conversion circuit. They also have a significant effect upon the overall performance and efficiency of the system. Accordingly, the design of such transformers has an important effect on overall system weight, power-inversion efficiency, and cost. Relationships were between the parameters used by transformer designers that can be used as new tools to standardize and simplify transformer design. They can be used to optimize the design either for small size and weight or efficiency. The metric system of units, rather than the familiar English units, is used; however, material is presented to assist the reader in the transition from one system to the other.
Keep this discovery
Explore connections, maps & timelines
Mclyman, W. T.. 1977-03-15. Transformer design tradeoffs. https://ntrs.nasa.gov/citations/19770017440