Engineering PapersSearch

NASA NTRS · 19750061548

Centaur propellant acquisition system

Abstract

The desirability of replacing the hydrogen peroxide settling system of the Centaur D-1S with a capillary acquisition system was evaluated. A comprehensive screening was performed to select the most promising capillary device fluid acquisition, thermal conditioning, and fabrication techniques. Refillable start baskets and bypass feed start tanks were selected for detailed design. Critical analysis areas were settling and refilling, start sequence development with an initially dry boost pump, and cooling the fluid delivered to the boost pump to provide the necessary net positive suction head (NPSH). Design drawings were prepared for start basket and start tank concepts for both the liquid oxygen and liquid hydrogen tanks. System comparisons indicated that the start baskets using wicking flow for thermal conditioning, and thermal subcooling for providing boost pump NPSH, are the most desirable systems for future Centaur acquisition system development.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Blatt, M. H., Aydelott, J. C.. 1975-09-01. Centaur propellant acquisition system. https://ntrs.nasa.gov/citations/19750061548

Cite the original work for its findings. Save a collection to share your selection of sources.