Engineering Papers⌕ Search

NASA NTRS · 19750049854

Flow rates for sharp-edged orifices

Abstract

Two charts are proposed for calculating the flow coefficient and the area correction factor used in the equation for the flow rate through a sharp-edged orifice. The proposed charts account for variations in the discharge coefficient of sharp-edged orifices and can be used with any pressure ratio for both subcritical and supercritical flow conditions. They can also be used for any gas by using the appropriate gas constant and ratio of specific heats. The application of the charts is illustrated by examples.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Groesbeck, W. A., Manning, F. L.. 1975-06-12. Flow rates for sharp-edged orifices. https://ntrs.nasa.gov/citations/19750049854

Cite the original work for its findings. Save a collection to share your selection of sources.