Dual measurement ablation sensor
Abstract
A dual measurement ablation sensor for measuring both char-interface and surface recession at a point in an ablating material is described. The sensor permits measurement of the thickness of the char layer. Char-interface recession is indicated by a drop in the resistance to a current passed through the ablation material. Surface recession is indicated by the closing of an electrical circuit when melting causes the release of a spring switch.