NASA NTRS · 19720011218
Apollo oxygen tank stratification analysis, volume 2
Abstract
An analysis of flight performance of the Apollo 15 cryogenic oxygen tanks was conducted with the variable grid stratification math model developed earlier in the program. Flight conditions investigated were the CMP-EVA and one passive thermal control period which exhibited heater temperature characteristics not previously observed. Heater temperatures for these periods were simulated with the math model using flight acceleration data. Simulation results (heater temperature and tank pressure) compared favorably with the Apollo 15 flight data, and it was concluded that tank performance was nominal. Math model modifications were also made to improve the simulation accuracy. The modifications included the addition of the effects of the tank wall thermal mass and an improved system flow distribution model. The modifications improved the accuracy of simulated pressure response based on comparisons with flight data.
Keep this discovery
Explore connections, maps & timelines
Barton, J. E., Patterson, H. W.. 1972-01-31. Apollo oxygen tank stratification analysis, volume 2. https://ntrs.nasa.gov/citations/19720011218
Cite the original work for its findings. Save a collection to share your selection of sources.