Engineering Papers⌕ Search

Engineering topics

Zipperer, Travis J.

Publications and source records attributed to Zipperer, Travis J..

Estimating the Contribution of the Nickel to Protium Loading of Full-Length Getters

The full-length getter (FLG) is a critical component of the tritium producing burnable absorber rod (TPBAR), designed to capture tritium produced within the lithium aluminate pellets. However, due to the chemical similarity between protium (¹H) and tritium (³H), the FLG readily absorbs protium, reducing its capacity to absorb tritium and increasing the risk of tritium permeation into the reactor coolant. This study evaluates protium produced from neutron irradiation of nickel plating on the FLG through 5?Ni(n,p) reactions, quantifies its contribution to the total protium observed, and informs models of tritium and hydrogen transport within TPBARs. During irradiation, neutron capture by 58Ni results in the formation of 5?Ni, which undergoes neutron bombardment to produce 4He via 5?Ni(n,a) reactions and protium via 5?Ni(n,p) reactions. The measured helium content post-irradiation provides insight into the neutron capture processes within the getter. The 4He measured within the getter may be useful in determining hydrogen produced by the nickel plating on FLG because 59Ni also produces protium in a 59Ni(n, p) reaction. The contribution of 1H from the nickel in FLG contributed less than 1% of the measured H2 gas in PIE, ranging from 0.005% to 0.614%. These findings refine current knowledge of the protium-tritium interplay in TPBARs and support the development of improved transport models for tritium and hydrogen, ultimately aiding in the optimization of TPBAR design and reactor operations.

Arbova, Dana L.↗

Sum-of-Fractions Methodology for Actinides in Water- and Polyethylene-Moderated and -Reflected Systems

Sum-of-fractions is a method intended to make sure a subcritical margin for aqueous solutions and slurries of fissionable isotopes exists. The method indicates that a system is subcritical if the sum of the ratios of the mass of each isotope (in a mixture) to its individual minimum subcritical mass limit is less than or equal to one. Historically, the basis of the sum-of-fractions has been derived from allowances given in the American National Standards Institute (ANSI)/ American Nuclear Society (ANS)-8.15-1981. However, the allowance was removed in ANSI/ANS-8.15-2014 due to a lack of technical basis. A methodology was developed to assess the validity of using the sum-of-fractions for water- or polyethylene-moderated systems for the following nuclides: 232 U, 233 U, 234 U, 235 U, 237 Np, 236 Pu, 238 Pu, 239 Pu, 240 Pu, 241 Pu, 242 Pu, 241 Am, 242 m Am, 243 Am, 242 Cm, 243 Cm, 244 Cm, 245 Cm, 246 Cm, 247 Cm, 249 Cf, and 251 Cf. The methodology uses available benchmark data for mixtures of 233 U, 235 U, and 239 Pu to establish the calculational margin, and a mass limit reduction to establish the margin of subcriticality. Water- or polyethylene-moderated and -reflected mixtures containing the nuclides are evaluated with the code system, SCALE 6.2.4. Including the calculational margin, subcritical mass limits for each nuclide were computed for optimally water- or polyethylene-moderated and fully reflected systems. These masses were used to create nuclide mixtures in which the sum of the mass to subcritical mass limit ratios is one. The various nuclide mixtures were modeled over a range of moderation and demonstrate the keff does not exceed the calculational margin. For additional assurance of subcriticality, a significant mass reduction is applied to each computed minimum critical mass of the nuclides without adequate benchmark data consistent with the method in ANSI/ANS-8.15-2014.

07 ISOTOPE AND RADIATION SOURCES↗

Evaluation of the Sum-of-Fractions Methodology for Water and Polyethylene Moderated Systems

Sum-of-Fractions is a method intended to assure a subcritical margin for aqueous solutions and slurries of fissionable isotopes. The method indicates that a system is subcritical if the sum of the ratios of the mass of each isotope in a mixture to its individual minimum subcritical mass limit is less than or equal to one. The basis of the Sum-of Fractions has historically been derived from allowances given in ANSI/ANS-8.15-1981. However, the allowance was removed in ANSI/ANS-8.15-2014 due to a lack of technical basis. A methodology was developed to assess the validity of using the Sum-of-Fractions for water or polyethylene moderated systems for the following nuclides: 232 U, 233 U, 234 U, 235 U, 237 Np, 236 Pu, 238 Pu, 239 Pu, 240 Pu, 241 Pu, 242 Pu, 241 Am, 242 mAm, 243 Am, 242 Cm, 243 Cm, 244 Cm, 245 Cm, 246 Cm, 247 Cm, 249 Cf, and 251 Cf. The methodology uses available benchmark data for mixtures of 233 U, 235 U, and 239 Pu to establish the calculational margin, and a mass limit reduction to establish the margin of subcriticality. Water or polyethylene moderated and reflected mixtures containing the nuclides are evaluated with SCALE 6.2.4. Including the calculational margin, subcritical mass limits for each nuclide were computed for optimally water or polyethylene moderated and fully reflected systems. These masses were used to create nuclide mixtures in which the sum of the mass to subcritical mass limit ratios is one. The various nuclide mixtures were modeled over a range of moderation and demonstrate the k eff does not exceed the calculational margin. For additional assurance of subcriticality, a significant mass reduction is applied to each computed minimum critical mass of the nuclides without adequate benchmark data consistent with the method in ANSI/ANS-8.15-2014.

07 ISOTOPE AND RADIATION SOURCES↗

FAST-1.2 User Installation and Verification Guide: Developed Under NQA-1-2017

The purpose of this document is to provide the user information about the installation of Fuel Analysis for Steady state and Transient (FAST)-1.2 on their computers or servers. General information about the code and supported operating systems is described in Section 1.0. Self-service oriented FAST-1.2 software licensing steps are described in Section 2.0. An installation verification test suite is provided with FAST-1.2 and described in Section 3.0. A convenience script for converting Fuel Rod Analysis Program – Constant (FRAPCON) to FAST inputs is discussed in Section 4.0. FAST-1.2 was developed and released under a software quality assurance program based upon NQA-1-2017 at Pacific Northwest National Laboratory (PNNL). FAST-1.2 is the latest baseline code. The installation verification test suite contains both steady state and transient Anticipated Operation Occurrences (AOOs), accident conditions, such as Reactivity Initiated Accidents (RIAs) and Loss of Coolant Accidents (LOCAs).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

FAST-1.1: Integral Assessment

An integral assessment has been performed to quantify the predictive capabilities of FAST, a thermal-mechanical nuclear fuel performance code designed to analyze fuel behavior from beginning of life to burnup levels allowed by the U.S. Nuclear Regulatory Commission (NRC). FAST code calculations are shown to compare satisfactorily to a preselected set of experimental data with both steady-state and anticipated operating occurrence (AOO) conditions and design basis accident (DBA) transient operating conditions. This document describes the assessment of FAST-1.1, the latest version of FAST, released April 2022. Abstract

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗