Engineering Papers⌕ Search

Engineering topics

Zhong, Z

Publications and source records attributed to Zhong, Z.

At least 37 records · Page 2

MCNPX, MONK, and ERANOS analyses of the YALINA booster subcritical assembly.

This paper compares the numerical results obtained from various nuclear codes and nuclear data libraries with the YALINA Booster subcritical assembly (Minsk, Belarus) experimental results. This subcritical assembly was constructed to study the physics and the operation of accelerator-driven subcritical systems (ADS) for transmuting the light water reactors (LWR) spent nuclear fuel. The YALINA Booster facility has been accurately modeled, with no material homogenization, by the Monte Carlo codes MCNPX (MCNP/MCB) and MONK. The MONK geometrical model matches that of MCNPX. The assembly has also been analyzed by the deterministic code ERANOS. In addition, the differences between the effective neutron multiplication factor and the source multiplication factors have been examined by alternative calculational methodologies. The analyses include the delayed neutron fraction, prompt neutron lifetime, generation time, neutron flux profiles, and spectra in various experimental channels. The accuracy of the numerical models has been enhanced by accounting for all material impurities and the actual density of the polyethylene material used in the assembly (the latter value was obtained by dividing the total weight of the polyethylene by its volume in the numerical model). There is good agreement between the results from MONK, MCNPX, and ERANOS. The ERANOS results show small differences relative to the other results because of material homogenization and the energy and angle discretizations.The MCNPX results match the experimental measurements of the {sup 3}He(n,p) reaction rates obtained with the californium neutron source.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Gold Nanoparticles Enhance the Radiation Therapy of a Murine Squamous Cell Carcinoma

The purpose of this study is to test the hypothesis that gold nanoparticle (AuNP, nanogold)-enhanced radiation therapy (nanogold radiation therapy, NRT) is efficacious when treating the radiation resistant and highly aggressive mouse head and neck squamous cell carcinoma model, SCCVII, and to identify parameters influencing the efficacy of NRT. Subcutaneous (sc) SCCVII leg tumors in mice were irradiated with x-rays at the Brookhaven National Laboratory (BNL) National Synchrotron Light Source (NSLS) with and without prior intravenous (iv) administration of AuNPs. Variables studied included radiation dose, beam energy, temporal fractionation and hyperthermia. AuNP-mediated NRT was shown to be effective for the sc SCCVII model. AuNPs were more effective at 42 Gy than at 30 Gy (both at 68 keV median beam energy) compared to controls without gold. Similarly, at 157 keV median beam energy, 50.6 Gy NRT was more effective than 44 Gy NRT. At the same radiation dose (42 Gy), 68 keV was more effective than 157 keV. Hyperthermia and radiation therapy (RT) were synergistic and AuNPs enhanced this synergy, thereby further reducing TCD50 s (tumor control dose 50%) and increasing long-term survivals. It is concluded that gold nanoparticles enhance the radiation therapy of a radioresistant mouse squamous cell carcinoma. The data show that radiation dose, energy and hyperthermia influence efficacy and better define the potential utility of gold nanoparticles for cancer x-ray therapy.

43 PARTICLE ACCELERATORS↗

Origin of the non-linear pressure effects in perovskite manganties: Buckling of Mn-O-Mn bonds and Jahn-Teller distortion of the MnO6 octahedra induced by pressure.

High-pressure resistivity and X-ray diffraction measurements were conducted on La{sub 0.85}MnO{sub 3-{delta}} at 6 and 7 GPa, respectively. At low pressures the metal-insulator transition temperature (TMI) increases linearly up to a critical pressure, P* {approx} 3.4 GPa, followed by reduction in T{sub MI} at higher pressure. Analysis of the bond distances and bond angles reveals that a bandwidth increase drives the increase in T{sub MI} below P*. The reduction in T{sub MI} at higher pressures is found to result from Jahn-Teller distortions of the MnO{sub 6} octahedra. The role of anharmonic interatomic potentials is discussed.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Use of synchrotron based diffraction enhanced imaging for visualization of soft tissues in invertebrates

Images of terrestrial and marine invertebrates (snails and bivalves) have been obtained by using an X-ray phase-contrast imaging technique, namely, synchrotron-based diffraction-enhanced imaging. Synchrotron X-rays of 20, 30 and 40 keV were used, which penetrate deep enough into animal soft tissues. The phase of X-ray photons shifts slightly as they traverse an object, such as animal soft tissue, and interact with its atoms. Biological features, such as shell morphology and animal physiology, have been visualized. The contrast of the images obtained at 40 keV is the best. This optimum energy provided a clear view of the internal structural organization of the soft tissue with better contrast. The contrast is higher at edges of internal soft-tissue structures. The image improvements achieved with the diffraction-enhanced imaging technique are due to extinction, i.e., elimination of ultra-small-angle scattering. They enabled us to identify a few embedded internal shell features, such as the origin of the apex, which is the firmly attached region of the soft tissue connecting the umbilicus to the external morphology. Diffraction-enhanced imaging can provide high-quality images of soft tissues valuable for biology.

43 PARTICLE ACCELERATORS↗

High Pressure Research at the National Synchrotron Light Source

The National Synchrotron Light Source at Brookhaven National Laboratory has been home to a successful high-pressure program for over 20 years. The first dedicated high-pressure diffraction endstation, X17C, was etablished at NSLS in 1990. A large number of new techniques have been developed at this beamline, including double-sided laser heating, single crystal diffraction above 60 GPa, x-ray diffraction measurements in a resistive heated diamond anvil cell (DAC) at 1300 K and 1 megabar, the first high-pressure and low-temperature experiment, and radial diffraction in a DAC.

43 PARTICLE ACCELERATORS↗

Cork Embedded Internal Features and Contrast Mechanisms with DEI using 18, 20, 30, 36, and 40 kev Synchrotron X-rays

Images of the cork used for wine and other bottles are visualized with the use of diffraction-enhanced imaging (DEI) technique. Present experimental studies allowed us to identify the cracks, holes, porosity, and importance of soft-matter (soft-material) and associated biology by visualization of the embedded internal complex features of the biological material such as cork and its microstructure. Highlighted the contrast mechanisms above and below the K-absorption edge of iodine and studied the attenuation through a combination of weakly and strongly attenuating materials.

36 MATERIALS SCIENCE↗

Cork Embedded Internal Features and Contrast Mechanisms with Del Using 18, 20, 30, 36 and 40 keV Synchrotron X-rays

Images of the cork used for wine and other bottles are visualized with the use of diffraction-enhanced imaging (DEI) technique. Present experimental studies allowed us to identify the cracks, holes, porosity, and importance of soft-matter (soft-material) and associated biology by visualization of the embedded internal complex features of the biological material such as cork and its microstructure. Highlighted the contrast mechanisms above and below the K-absorption edge of iodine and studied the attenuation through a combination of weakly and strongly attenuating materials.

43 PARTICLE ACCELERATORS↗

Biological shield design and analysis of KIPT accelerator-driven subcritical facility.

Argonne National Laboratory of the United States and Kharkov Institute of Physics and Technology of Ukraine have been collaborating on the conceptual design development of an electron accelerator-driven subcritical facility. The facility will be utilized for performing basic and applied nuclear research, producing medical isotopes, and training young nuclear specialists. This paper presents the design and analyses of the biological shield performed for the top section of the facility. The neutron source driving the subcritical assembly is generated from the interaction of a 100-kW electron beam with a natural uranium target. The electron energy is in the range of 100 to 200 MeV, and it has a uniform spatial distribution. The shield design and the associated analyses are presented including different parametric studies. In the analyses, a significant effort was dedicated to the accurate prediction of the radiation dose outside the shield boundary as a function of the shield thickness without geometrical approximations or material homogenization. The MCNPX Monte Carlo code was utilized for the transport calculation of electrons, photons, and neutrons. Weight window variance-reduction techniques were introduced, and the dose equivalent outside the shield can be calculated with reasonably good statistics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Burnup calculations for KIPT accelerator driven subcritical facility using Monte Carlo computer codes-MCB and MCNPX.

Argonne National Laboratory (ANL) of USA and Kharkov Institute of Physics and Technology (KIPT) of Ukraine have been collaborating on the conceptual design development of an electron accelerator driven subcritical (ADS) facility, using the KIPT electron accelerator. The neutron source of the subcritical assembly is generated from the interaction of 100 KW electron beam with a natural uranium target. The electron beam has a uniform spatial distribution and electron energy in the range of 100 to 200 MeV. The main functions of the subcritical assembly are the production of medical isotopes and the support of the Ukraine nuclear power industry. Neutron physics experiments and material structure analyses are planned using this facility. With the 100 KW electron beam power, the total thermal power of the facility is {approx}375 kW including the fission power of {approx}260 kW. The burnup of the fissile materials and the buildup of fission products reduce continuously the reactivity during the operation, which reduces the neutron flux level and consequently the facility performance. To preserve the neutron flux level during the operation, fuel assemblies should be added after long operating periods to compensate for the lost reactivity. This process requires accurate prediction of the fuel burnup, the decay behavior of the fission produces, and the introduced reactivity from adding fresh fuel assemblies. The recent developments of the Monte Carlo computer codes, the high speed capability of the computer processors, and the parallel computation techniques made it possible to perform three-dimensional detailed burnup simulations. A full detailed three-dimensional geometrical model is used for the burnup simulations with continuous energy nuclear data libraries for the transport calculations and 63-multigroup or one group cross sections libraries for the depletion calculations. Monte Carlo Computer code MCNPX and MCB are utilized for this study. MCNPX transports the electrons and the produced neutrons and photons but the current version of MCNPX doesn't support depletion/burnup calculation of the subcritical system with the generated neutron source from the target. MCB can perform neutron transport and burnup calculation for subcritical system using external neutron source, however it cannot perform electron transport calculations. To solve this problem, a hybrid procedure is developed by coupling these two computer codes. The user tally subroutine of MCNPX is developed and utilized to record the information of the each generated neutron from the photonuclear reactions resulted from the electron beam interactions. MCB reads the recorded information of each generated neutron thorough the user source subroutine. In this way, the neutron source generated by electron reactions could be utilized in MCB calculations, without the need for MCB to transport the electrons. Using the source subroutines, MCB could get the external neutron source, which is prepared by MCNPX, and perform depletion calculation for the driven subcritical facility.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Radiologist Evaluation of an X-ray Tube Based Diffraction Enhanced Imaging Prototype Using Full Thickness Breast Specimens.

Conventional mammographic image contrast is derived from x-ray absorption, resulting in breast structure visualization due to density gradients that attenuate radiation without distinction between transmitted, scattered, or refracted x-rays. Diffraction-enhanced imaging (DEI) allows for increased contrast with decreased radiation dose compared to conventional mammographic imaging because of monochromatic x-rays, its unique refraction-based contrast mechanism, and excellent scatter rejection. However, a lingering drawback to the clinical translation of DEI has been the requirement for synchrotron radiation. The authors laboratory developed a DEI prototype (DEI-PR) using a readily available tungsten x-ray tube source and traditional DEI crystal optics, providing soft tissue images at 60 keV. Images of full-thickness human breast tissue specimens were acquired on synchrotron-based DEI (DEI-SR), DEI-PR, and digital mammographic systems. A panel of expert radiologists evaluated lesion feature visibility and correlation with pathology after receiving training on the interpretation of refraction contrast mammographic images. For mammographic features (mass, calcification), no significant differences were detected between the DEI-SR and DEI-PR systems. Benign lesions were perceived as better seen by radiologists using the DEI-SR system than the DEI-PR system at the [111] reflectivity, with generalizations limited by small sample size. No significant differences between DEI-SR and DEI-PR were detected for any other lesion type (atypical, cancer) at either crystal reflectivity. Thus, except for benign lesion characterizations, the DEI-PR system's performance was roughly equivalent to that of the traditional DEI system, demonstrating a significant step toward clinical translation of this modality for breast cancer applications.

59 BASIC BIOLOGICAL SCIENCES↗