Engineering PapersSearch

Engineering topics

Zheng, Yun

Publications and source records attributed to Zheng, Yun.

Molecular Engineering Enabled Stable Deep Eutectic Amide-Based Electrolyte for High-Temperature Lithium–Metal Batteries

The development of advanced lithium-metal batteries (LMBs), such as high-temperature LMBs and high-energy-density LMBs, has critical requirements for electrolytes. However, conventional electrolytes suffer from thermal instability and insufficient electrolyte/Li interfacial compatibility, severely limiting their utilization in high-temperature LMBs. Herein, we design a high-temperature N-methylacetamide (NMAc)-based deep eutectic electrolyte (DEE) by molecular engineering on a solvation structure via a sacrificial additive of vinyl ethylene carbonate (VEC). Specifically, VEC interacts with the Li prior to NMAc, facilitating the formation of a solid electrolyte interphase to inhibit the reaction between Li and NMAc. The stable VEC-DEE effectively suppresses the growth of lithium dendrites and ensures the battery a cycling stability of 550 cycles at 80 °C. Additionally, we also demonstrate the application of VEC-DEE in high-energy-density LMBs with a high mass loading of 2.5 mAh/cm 2 . In conclusion, this research opens a new avenue for the rational design of advanced high-temperature electrolytes.

25 ENERGY STORAGE

Automated Scenario Generation for Meeting Human-in-the-Loop Simulation Requirements

A two-step automated Multi-Aircraft Control System traffic scenario generation process for Human-in-the-Loop evaluations of air traffic management concepts is described. The first step of the two-step process employs the scenario generation capability currently available in NASA's Air Traffic Management Testbed. The second step refines the scenario by filtering flights from the traffic scenario based on route length, cruise speed, cruise altitude, entry time and the desired ratio of internal to external flights. A solution for achieving the desired ratio of internal to external flights, where internal flights are shorter flights and external flights are longer flights based on a distance threshold, is described. Finally, schedulers are described for shaping the hourly arrival traffic count as a function of time in response to airport capacity constraint or for increasing the traffic demand with respect to the available arrival capacity. Results generated for arrival traffic to the four major airports in the New York Metroplex on a busy day using the two-step procedure are discussed. These results show that traffic scenarios for Multi-Aircraft Control System that meet the Human-in-the-Loop and fast-time simulation requirements can be created automatically following the procedures described in the paper. The automated process will improve the accuracy and efficiency by eliminating the tedious manual process for scenario generation.

Automated Scenario Generation

Automated Scenario Generation for Meeting Human-In-The-Loop Simulation Requirements

A two-step automated Multi-Aircraft Control System traffic scenario generation process for Human-in-the-Loop evaluations of air traffic management concepts is described. The first step of the two-step process employs the scenario generation capability currently available in NASA's Air Traffic Management Testbed. The second step refines the scenario by filtering flights from the traffic scenario based on route length, cruise speed, cruise altitude, entry time and the desired ratio of internal to external flights. A solution for achieving the desired ratio of internal to external flights, where internal flights are shorter flights and external flights are longer flights based on a distance threshold, is described. Finally, schedulers are described for shaping the hourly arrival traffic count as a function of time in response to airport capacity constraint or for increasing the traffic demand with respect to the available arrival capacity. Results generated for arrival traffic to the four major airports in the New York Metroplex on a busy day using the two-step procedure are discussed. These results show that traffic scenarios for Multi-Aircraft Control System that meet the Human-in-the-Loop and fast-time simulation requirements can be created automatically following the procedures described in the paper. The automated process will improve the accuracy and efficiency by eliminating the tedious manual process for scenario generation.

Automated Scenario Generation

Automated Scenario Generation for Human-in-the-Loop Simulations

Automated Multi-Aircraft Control System scenario generation for Human-in-the-Loop evaluations of air traffic management concepts is described. Methods for analyzing and comparing the seed-scenario generated using the automated process and the Human-in-the-Loop-scenario designed to meet the experiment objectives are discussed. The main findings are: (1) many of the characteristics of the seed-scenario used for constructing the Human-in-the-Loop-scenario are preserved in the Human-in-the-Loop Scenario, (2) landing characteristics of the traffic generated by the Multi-Aircraft Control System using the input scenario compare reasonably well with that intended in the input scenario, and (3) many of desired characteristics of the Human-in-the-Loop-scenario can be achieved by further automation.

SMART-NAS Testbed

Automated Scenario Generation for Human-in-the-Loop Simulations

Automated Multi-Aircraft Control System scenario generation for Human-in-the-Loop (HITL) evaluations of air traffic management concepts is described. The objective is to replace the difficult manual process with the automated process for creating an initial (seed) scenario that serves as a starting point for manual adjustments for creating the Human-in-the-Loop scenario. Methods for analyzing and comparing the seed-scenario generated using the automated process and the Human-in-the-Loop-scenario derived from it to meet the experiment objectives are discussed. Results of comparison of input Human-in-the-Loop-scenario with the Multi-Aircraft Control System output are also presented. The main findings are: (1) many of the characteristics of the seed-scenario used for constructing the Human-in-the-Loop-scenario are preserved in the Human-in-the-Loop-scenario, (2) landing rate profile of the traffic generated by the Multi-Aircraft Control System (MACS) using the input scenario compares reasonably well with that intended in the input scenario, and (3) many of the desired characteristics of the Human-in-the-Loop-scenario can be achieved by further automation.

Automated Scenario Generation

2D Electrostatic Actuation of Microshutter Arrays

An electrostatically actuated microshutter array consisting of rotational microshutters (shutters that rotate about a torsion bar) were designed and fabricated through the use of models and experiments. Design iterations focused on minimizing the torsional stiffness of the microshutters, while maintaining their structural integrity. Mechanical and electromechanical test systems were constructed to measure the static and dynamic behavior of the microshutters. The torsional stiffness was reduced by a factor of four over initial designs without sacrificing durability. Analysis of the resonant behavior of the microshutter arrays demonstrates that the first resonant mode is a torsional mode occurring around 3000 Hz. At low vacuum pressures, this resonant mode can be used to significantly reduce the drive voltage necessary for actuation requiring as little as 25V. 2D electrostatic latching and addressing was demonstrated using both a resonant and pulsed addressing scheme.

Multiobject Imaging

Enabling Microliquid Chromatography by Microbead Packing of Microchannels

The microbead packing is the critical element required in the success of on-chip microfabrication of critical microfluidic components for in-situ analysis and detection of chiral amino acids. In order for microliquid chromatography to occur, there must be a stationary phase medium within the microchannel that interacts with the analytes present within flowing fluid. The stationary phase media are the microbeads packed by the process discussed in this work. The purpose of the microliquid chromatography is to provide a lightweight, low-volume, and low-power element to separate amino acids and their chiral partners efficiently to understand better the origin of life. In order to densely pack microbeads into the microchannels, a liquid slurry of microbeads was created. Microbeads were extracted from a commercially available high-performance liquid chromatography column. The silica beads extracted were 5 microns in diameter, and had surface coating of phenyl-hexyl. These microbeads were mixed with a 200- proof ethanol solution to create a microbead slurry with the right viscosity for packing. A microfilter is placed at the outlet via of the microchannel and the slurry is injected, then withdrawn across a filter using modified syringes. After each injection, the channel is flushed with ethanol to enhance packing. This cycle is repeated numerous times to allow for a tightly packed channel of microbeads. Typical microbead packing occurs in the macroscale into tubes or channels by using highly pressurized systems. Moreover, these channels are typically long and straight without any turns or curves. On the other hand, this method of microbead packing is completed within a microchannel 75 micrometers in diameter. Moreover, the microbead packing is completed into a serpentine type microchannel, such that it maximizes microchannel length within a microchip. Doing so enhances the interactions of the analytes with the microbeads to separate efficiently amino acids and amino acid enantiomers.

Balvin, Manuel

Enabling Microliquid Chromatography by Microbead Packing of Microchannels

The microbead packing is the critical element required in the success of on-chip microfabrication of critical microfluidic components for in-situ analysis and detection of chiral amino acids. In order for microliquid chromatography to occur, there must be a stationary phase medium within the microchannel that interacts with the analytes present within flowing fluid. The stationary phase media are the microbeads packed by the process discussed in this work. The purpose of the microliquid chromatography is to provide a lightweight, low-volume, and low-power element to separate amino acids and their chiral partners efficiently to understand better the origin of life. In order to densely pack microbeads into the microchannels, a liquid slurry of microbeads was created. Microbeads were extracted from a commercially available high-performance liquid chromatography column. The silica beads extracted were 5 microns in diameter, and had surface coating of phenyl-hexyl. These microbeads were mixed with a 200- proof ethanol solution to create a microbead slurry with the right viscosity for packing. A microfilter is placed at the outlet via of the microchannel and the slurry is injected, then withdrawn across a filter using modified syringes. After each injection, the channel is flushed with ethanol to enhance packing. This cycle is repeated numerous times to allow for a tightly packed channel of microbeads. Typical microbead packing occurs in the macroscale into tubes or channels by using highly pressurized systems. Moreover, these channels are typically long and straight without any turns or curves. On the other hand, this method of microbead packing is completed within a microchannel 75 micrometers in diameter. Moreover, the microbead packing is completed into a serpentine type microchannel, such that it maximizes microchannel length within a microchip. Doing so enhances the interactions of the analytes with the microbeads to separate efficiently amino acids and amino acid enantiomers.

Balvin, Manuel

On-Chip Microfluidic Components for In Situ Analysis, Separation, and Detection of Amino Acids

The Astrobiology Analytical Laboratory at GSFC has identified amino acids in meteorites and returned cometary samples by using liquid chromatography-electrospray ionization time-of-flight mass spectrometry (LCMS). These organic species are key markers for life, having the property of chirality that can be used to distinguish biological from non-biological amino acids. One of the critical components in the benchtop instrument is liquid chromatography (LC) analytical column. The commercial LC analytical column is an over- 250-mm-long and 4.6-mm-diameter stainless steel tube filled with functionized microbeads as stationary phase to separate the molecular species based on their chemistry. Miniaturization of this technique for spaceflight is compelling for future payloads for landed missions targeting astrobiology objectives. A commercial liquid chromatography analytical column consists of an inert cylindrical tube filled with a stationary phase, i.e., microbeads, that has been functionalized with a targeted chemistry. When analyte is sent through the column by a pressurized carrier fluid (typically a methanol/ water mixture), compounds are separated in time due to differences in chemical interactions with the stationary phase. Different species of analyte molecules will interact more strongly with the column chemistry, and will therefore take longer to traverse the column. In this way, the column will separate molecular species based on their chemistry. A lab-on-chip liquid analysis tool was developed. The microfluidic analytical column is capable of chromatographically separating biologically relevant classes of molecules based on their chemistry. For this analytical column, fabrication, low leak rate, and stationary phase incorporation of a serpentine microchannel were demonstrated that mimic the dimensions of a commercial LC column within a 5 10 1 mm chip. The microchannel in the chip has a 75- micrometer-diameter oval-shaped cross section. The serpentine microchannel has four different lengths: 40, 60, 80, and 100 mm. Functionized microbeads were filled inside the microchannel to separate molecular species based on their chemistry.

Zheng, Yun

Non-Contact Stiffness Measurement of a Suspended Single Walled Carbon Nanotube Device

A new nanoscale electric field sensor was developed for studying triboelectric charging in terrestrial and Martian dust devils. This sensor is capable to measure the large electric fields for large dust devils without saturation. However, to quantify the electric charges and the field strength it is critical to calibrate the mechanical stiffness of the sensor devices. We performed a technical feasibility study of the Nano E-field Sensor stiffness by a non-contact stiffness measurement method. The measurement is based on laser Doppler vibrometer measurement of the thermal noise due to energy flunctuations in the devices. The experiment method provides a novel approach to acquire data that is essential in analyzing the quantitative performance of the E-field Nano Sensor. To carry out the non-contact stiffness measurement, we fabricated a new Single-Walled Carbon Nanotube (SWCNT) E-field sensor with different SWCNTs suspension conditions. The power spectra of the thermal induced displacement in the nano E-field sensor were measured at the accuracy of picometer. The power spectra were then used to derive the mechanical stiffness of the sensors. Effect of suspension conditions on stiffness and sensor sensitivty was discussed. After combined deformation and resistivity measurement, we can compare with our laboratory testing and field testing results. This new non-contact measurement technology can also help to explore to other nano and MEMS devices in the future.

Zheng, Yun

Fabrication of MEMS Microshutter Arrays for Cryogenic Applications

Two-dimensional MEMS microshutter arrays are being developed for use as a high contrast field selector for the Near Infrared Spectrograph (NIRSpec) on the James Webb Space Telescope (JWST). We present details of microshutter array fabrication and give results of work done to optimize the flatness of microshutter elements through film stress control for both room temperature and cryogenic (35K) operation.

Denis Kevin

Fabrication of Microshutter Arrays for James Webb Space Telescope

Two-dimensional MEMS microshutter arrays are being developed at NASA Goddard Space Flight Center for use in the near-infrared region on the Next Generation Space Telescope (NGST). The microshutter arrays are designed for the selective transmission of light with high efficiency and high contrast. The NGST environment requires cryogenic operation at 45K. Microshutter arrays are fabricated out of silicon-oxide-insulated (SOI) silicon wafers. Arrays are close-packed silicon nitride membranes with a pixel size of 100x100 microns. Individual shutters are patterned with a torsion flexure permitting shutters to open 90 degrees with a minimized mechanical stress concentration. The mechanical shutter arrays are fabricated using MEMS technologies. The processing includes a multi-layer metal deposition and patterning of shutter electrodes and magnetic pads, reactive ion etching (RE) of the front side to form shutters out of the nitride membrane, an anisotropic back-etch for wafer thinning, followed by a deep RIE (DRIE) back-etch down to the nitride shutter membrane to form frames and relieve shutters from the silicon substrate. An additional metal deposition and patterning is used to form back electrodes. Shutters are actuated using a magnetic force and latched using an electrostatic force.

Li, Mary J.