Engineering Papers⌕ Search

Engineering topics

Zheng, Yuan

Publications and source records attributed to Zheng, Yuan.

Understanding the negative triangularity ELM trigger and ELM free state on DIII-D with ECE-imaging

Here, the Electron Cyclotron Emission Imaging (ECEI) diagnostic was used to observe a finite-n interchange mode structure in the edge of negative triangularity shaped plasmas on DIII-D. At a small negative triangularity (δ u = -0.2), the plasma is in the H-mode with ELMs that are triggered by a low-n interchange mode. At a larger negative triangularity (δ u = -0.4) and low NBI power (2 MW), a dithering oscillation is observed that is triggered by a low-n interchange mode, whereas at higher NBI power (>2 MW), the edge reverts to L-mode and the low-n interchange mode is present continuously. In all cases, the edge pressure gradient is clamped when the interchange mode is present. It is concluded that the low-n interchange mode prevents the plasma from transitioning to H-mode at a large negative triangularity. This agrees with linear BOUT++ simulations which suggest that the interchange-type MHD can be a resistive ballooning mode whereby resistivity can significantly increase the finite-n ballooning mode growth rate. The absence of H-mode at large negative triangularity can, thus, be explained by the excitation of low-n pressure driven resistive ballooning modes in the plasma edge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnosing the pedestal magnetic field and magnetohydrodynamics radial structure with pedestal–scrape of layer electron cyclotron emission radiation inversion in H-mode plasma (invited)

Forward modeling is used to interpret inversion patterns of the pedestal–Scrape of Layer (SOL) Electron Cyclotron Emission (ECE) in DIII-D H-mode experiments. The modeling not only significantly improves the ECE data interpretation quality but also leads to the potential measurements of (1) the magnetic field strength |B| at the separatrix, (2) the pedestal |B| evolution during an inter-Edge Localized Mode (ELM) period, and (3) the pedestal Magnetohydrodynamics (MHD) radial structure. The ECE shine-through effect leads to three types of pedestal–SOL radiation inversions that are discussed in this paper. The first type of inversion is the non-monotonic T e,rad profile with respect to the major radius. Using the ECE frequency at the minimum T e,rad , the inversion can be applied to measure the magnetic field |B| at the separatrix and calibrate the mapping of the ECE channels with respect to the separatrix. The second type of inversion refers to the opposite phase between the radiation fluctuations δT e,rad at the pedestal and SOL. This δT e,rad phase inversion is sensitive to density and temperature fluctuations at the pedestal foot and, thus, can be used to qualitatively measure the MHD radial structure. The third type of inversion appears when the pedestal and SOL T e,rad evolve in an opposite trend, which can be used to infer the pedestal |B| field change during an inter-ELM period. Finally, the bandwidth effect on measuring δT e,rad due to pedestal MHD is also investigated in the radiation modeling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ECEI characterization of pedestal fluctuations in quiescent H-mode plasmas in DIII-D

Here, electron cyclotron emission imaging (ECEI) is employed to characterize the magneto hydraulics dynamics (MHD) fluctuations at the quiescent H-mode pedestals in DIII-D. Pedestal MHD fluctuations cause ECE radiation temperature fluctuations $\delta {T_{e{\text{,rad}}}}$ in both the pedestal and scrape-off-layer (SOL). A synthetic ECE platform is utilized for detailed interpretation of the ECEI signals in the SOL and pedestal regions. It is observed that the ECE radiation $\delta {T_{e{\text{,rad}}}}$, which is located in the SOL region according to the cold and optically thick plasma resonance assumption, is extremely sensitive to MHD radial displacements near the separatrix, exhibiting radiation inversion to $\delta {T_{e{\text{,rad}}}}$ at the pedestal. Here, the radiation inversion refers to the opposite phase between the radiation fluctuation at the pedestal and the radiation fluctuation at the SOL. Consequently, the quasi-coherent MHD (QCM), which displays a radiation inversion, is found to be consistent with an MHD radial structure that has a strong displacement near the separatrix. In contrast, the edge harmonic oscillation (EHO), which displays weak or no inversion, is found to be consistent with an MHD radial displacement structure peaking at the pedestal top. The ECEI data, interpreted with synthetic ECE, are in qualitative agreement with beam emission spectroscopy measurements on DIII-D for the relative radial extent and localization of the EHO and QCM. The high sensitivity of ECE radiation to separatrix displacements can be used to detect turbulence or MHD fluctuations near the separatrix, which may affect the transport across the separatrix and the wetted area in the divertor. The $\delta {T_{e{\text{,rad}}}}$ inversion measured with an ECE or ECEI system potentially provides important information on the magnetic field $\left| {{B_{{\text{sep}}}}} \right|$ at the separatrix, which helps constrain the pedestal equilibrium reconstruction and achieve an unambiguous mapping of the ECE/ECEI system with respect to the separatrix.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Underground Imaging by Sub-Terahertz Radiation

Sub-terahertz ground-penetrating radar systems offer an alternative to radio wave-based systems in the airborne imaging of buried objects. Laboratory prototype systems operating in W-band (75–110 GHz) and F-band (90–140 GHz) are presented, detecting the distance between target and source and imaging metal objects buried in mixed soil. The experimental results show that imaging in the 100–150 GHz frequency range is feasible for underground applications but significantly restricted by the attenuation characteristics of the medium covering the targets. A higher power source and more sensitive receiving components are essential to increase the penetration capability and expand the application settings of this approach.

42 ENGINEERING↗

Millimeter wave traveling wave tubes for the 21st Century

Traveling wave tubes are rapidly evolving to provide unprecedented power level in comparison to solid state devices in the millimeter waves region of the spectrum (80–300 GHz) thus enabling a wide range of applications. Wireless communications, imaging, plasma diagnostics, healthcare and many others will gain substantial features if high power at millimeter waves would be available from compact sources. The development of fabrication technologies is proving crucial for introducing new topologies and structures for millimeter wave vacuum electronic devices, compatible with the dimensions dictated by the short wavelength that poses substantial manufacturing challenges due to tight tolerances. This review paper will provide an overview of the principles, evolution and state of the art of one of the most widely utilized vacuum electronic device, the traveling wave tube (TWT). The wide band, high gain features of TWTs make those devices the most promising solutions for high power at millimeter waves and THz frequencies.

42 ENGINEERING↗