Engineering Papers⌕ Search

Engineering topics

Zhao, Wei

Publications and source records attributed to Zhao, Wei.

At least 91 records · Page 5

Observation and interpretation of energy efficient, diffuse direct current glow discharge at atmospheric pressure

A diffuse direct-current glow discharge was realized with low energy consumption and high energy utilization efficiency at atmospheric pressure. The formation of diffuse discharge was demonstrated by examining and comparing the electrical properties and optical emissions of plasmas. In combination with theoretical derivation and calculation, we draw guidelines that appearance of nitrogen ions at low electron density is crucial to enhance the ambipolar diffusion for the expansion of discharge channel and the increasing ambipolar diffusion near the cathode plays a key role in the onset of diffuse discharge. An individual-discharge-channel expansion model is proposed to explain the diffuse discharge formation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nanoscale Alloying in Electrocatalysts

In electrochemical energy conversion and storage, existing catalysts often contain a high percentage of noble metals such as Pt and Pd. In order to develop low-cost electrocatalysts, one of the effective strategies involves alloying noble metals with other transition metals. This strategy promises not only significant reduction of noble metals but also the tunability for enhanced catalytic activity and stability in comparison with conventional catalysts. In this report, some of the recent approaches to developing alloy catalysts for electrocatalytic oxygen reduction reaction in fuel cells will be highlighted. Furthermore, selected examples will be also discussed to highlight insights into the structural and electrocatalytic properties of nanoalloy catalysts, which have implications for the design of low-cost, active, and durable catalysts for electrochemical energy production and conversion reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microstructure of room temperature ionic liquids at stepped graphite electrodes

Molecular dynamics simulations of room temperature ionic liquid (RTIL) [emim][TFSI] at stepped graphite electrodes were performed to investigate the influence of the thickness of the electrode surface step on the microstructure of interfacial RTILs. A strong correlation was observed between the interfacial RTIL structure and the step thickness in electrode surface as well as the ion size. Specifically, when the step thickness is commensurate with ion size, the interfacial layering of cation/anion is more evident; whereas, the layering tends to be less defined when the step thickness is close to the half of ion size. Furthermore, two-dimensional microstructure of ion layers exhibits different patterns and alignments of counter-ion/co-ion lattice at neutral and charged electrodes. As the cation/anion layering could impose considerable effects on ion diffusion, the detailed information of interfacial RTILs at stepped graphite presented here would help to understand the molecular mechanism of RTIL-electrode interfaces in supercapacitors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanoalloy Printed and Pulse-Laser Sintered Flexible Sensor Devices with Enhanced Stability and Materials Compatibility

While conformal and wearable devices have become one of the most desired formats for printable electronics, it is challenging to establish a scalable process that produces stable conductive patterns but also uses substrates compatible with widely available wearable materials. Here, we describe findings of an investigation of a nanoalloy ink printed and pulsed laser sintered conductive patterns as flexible functional devices with enhanced stability and materials compatibility. While nanoparticle inks are desired for printable electronics, almost all existing nanoparticle inks are based on single-metal component, which, as an electronic element, is limited by its inherent stabilities of the metal such as propensity of metal oxidation and mobility of metal ions, especially in sintering processes. The work here has demonstrated the first example in exploiting plasmonic coupling of nanoalloys and pulsed-laser energy with controllable thermal penetration. The experimental and theoretical results have revealed clear correlation between the pulsed laser parameters and the nanoalloy structural characteristics. The superior performance of the resulting flexible sensor device, upon imparting nanostructured sensing materials, for detecting volatile organic compounds has significant implications to developing stable and wearable sensors for monitoring environmental pollutants and breath biomarkers. This simple “nanoalloy printing 'laser sintering' nanostructure printing” process is entirely general to many different sensor devices and nanostructured sensing materials, enabling the ability to easily construct sophisticated sensor array.

Environmental Molecular Sciences Laboratory↗

Deep inspiration breath-hold technique for left-sided breast cancer: An analysis of predictors for organ-at-risk sparing

To identify anatomic and treatment characteristics that correlate with organ-at-risk (OAR) sparing with deep inspiration breath-hold (DIBH) technique to guide patient selection for this technique. Anatomic and treatment characteristics and radiation doses to OARs were compared between free-breathing and DIBH plans. Linear regression analysis was used to identify factors independently predicting for cardiac sparing. We identified 64 patients: 44 with intact breast and 20 postmastectomy. For changes measured directly on treatment planning scans, DIBH plans decreased heart-chest wall length (6.5 vs 5.0 cm, p < 0.001), and increased lung volume (1074.4 vs 1881.3 cm{sup 3}, p < 0.001), and for changes measured after fields are set, they decreased maximum heart depth (1.1 vs 0.3 cm, p < 0.001) and heart volume in field (HVIF) (9.1 vs 0.9 cm{sup 3}, p < 0.001). DIBH reduced the mean heart dose (3.4 vs 1.8 Gy, p < 0.001) and lung V{sub 20} (19.6% vs 15.3%, p < 0.001). Regression analysis found that only change in HVIF independently predicted for cardiac sparing. We identified patients in the bottom quartile of the dosimetric benefits seen with DIBH and categorized the cause of this “minimal benefit.” Overall, 29% of patients satisfied these criteria for minimal benefit with DIBH and the most common cause was favorable baseline anatomy. Only the reduction in HVIF predicted for reductions in mean heart dose; no specific anatomic surrogate for the dosimetric benefits of DIBH technique could be identified. Most patients have significant dosimetric benefit with DIBH, and this technique should be planned and evaluated for all patients receiving left-sided breast/chest wall radiation.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Computational Study of Dicationic Ionic Liquids/CO 2 Interfaces

Our recent studies on CO 2 capture using dicationic ionic liquids (DILs) demonstrated that DILs are promising absorbents for CO 2 uptake especially compared with monocationic ionic liquids (MILs) analogues, in which each cation carries single positive charge in contrast to two unit charges of a dication. However, DILs/CO 2 interfacial properties at the molecular level are still unknown. This work investigated the CO 2 absorption properties of representative DILs, 1-alkyl-3-dimethylimidazolium bis(trifluoromethylsulfonyl)imide, [C n (mim) 2 ](Tf 2 N) 2 (n = 3, 6, 12), using molecular dynamics (MD) simulations. The higher interfacial CO 2 density at DIL than that at MIL interfaces suggests the increased CO 2 interaction sites in DILs. The interfacial CO 2 density also exhibits an alkyl chain length dependence which decreases with the elongation of alkyl chain and proportionally correlates with the content of fluorine atoms at interfaces. Different alkyl chain orientations in DILs were illustrated in contrast to those of MILs; both DILs and CO2 inside DILs exhibit lower diffusivity than MILs, in agreement with the stronger cation–anion binding energy of DILs. Moreover, DILs show a lower H2O and N2 uptake from flue gas compared with MILs, implicating the higher CO 2 /H 2 O and CO 2 /N 2 selectivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A methyltransferase required for proper timing of the vernalization response in Arabidopsis

Significance Proper timing of flowering is a key factor in reproductive success. Certain plant species require prolonged cold exposure during winter to flower in the spring; however, how plants measure the duration of cold exposure is not well understood. In this study, we describe the identification of a methyltransferase that is required for proper measurement of the duration of cold exposure.

59 BASIC BIOLOGICAL SCIENCES↗

Multi-scale simulation of the stability and diffusion of lithium in the presence of a 90° partial dislocation in silicon

The stable positions, binding energies, and dynamic properties of Li impurity in the presence of a 90° partial dislocation in Si have been studied by using the multi-scale simulation method. The corresponding results are compared with the defect-free Si crystal in order to reflect how the dislocation defect affects the performances of Li-ion batteries (LIBs) at the atomic level. It is found that the inserted Li atom in the dislocation core and nearest regions is more stable, since the binding energies are 0.13 eV to 0.52 eV larger than the bulk Si. Moreover, it is easier for Li atom to diffuse into those defect areas and harder to diffuse out. Thus, Li dopant may tend to congregate in the dislocation core and nearest regions. On the other side, the 90° partial dislocation can glide in the (111) plane accompanied by the diffusion of Li impurity along the pentagon ring of core. In addition, the spacious heptagon ring of dislocation core can lower the migration barrier of Li atom from 0.63 eV to 0.34 eV, which will enhance the motion of the dopant. Therefore, the presence of 90° partial dislocations may provide a fast and favorable diffusion path for the congregated Li impurity, which finally facilitates the lithiation of LIBs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The effect of amorphous selenium detector thickness on dual-energy digital breast imaging

Purpose: Contrast enhanced (CE) imaging techniques for both planar digital mammography (DM) and three-dimensional (3D) digital breast tomosynthesis (DBT) applications requires x-ray photon energies higher than the k-edge of iodine (33.2 keV). As a result, x-ray tube potentials much higher (>40 kVp) than those typical for screening mammography must be utilized. Amorphous selenium (a-Se) based direct conversion flat-panel imagers (FPI) have been widely used in DM and DBT imaging systems. The a-Se layer is typically 200 μm thick with quantum detective efficiency (QDE) >87% for x-ray energies below 26 keV. However, QDE decreases substantially above this energy. To improve the object detectability of either CE-DM or CE-DBT, it may be advantageous to increase the thickness (d{sub Se}) of the a-Se layer. Increasing the d{sub Se} will improve the detective quantum efficiency (DQE) at the higher energies used in CE imaging. However, because most DBT systems are designed with partially isocentric geometries, where the gantry moves about a stationary detector, the oblique entry of x-rays will introduce additional blur to the system. The present investigation quantifies the effect of a-Se thickness on imaging performance for both CE-DM and CE-DBT, discussing the effects of improving photon absorption and blurring from oblique entry of x-rays. Methods: In this paper, a cascaded linear system model (CLSM) was used to investigate the effect of d{sub Se} on the imaging performance (i.e., MTF, NPS, and DQE) of FPI in CE-DM and CE-DBT. The results from the model are used to calculate the ideal observer signal-to-noise ratio, d′, which is used as a figure-of-merit to determine the total effect of increasing d{sub Se} for CE-DM and CE-DBT. Results: The results of the CLSM show that increasing d{sub Se} causes a substantial increase in QDE at the high energies used in CE-DM. However, at the oblique projection angles used in DBT, the increased length of penetration through a-Se introduces additional image blur. The reduced MTF and DQE at high spatial frequencies lead to reduced two-dimensional d′. These losses in projection image resolution may subsequently result in a decrease in the 3D d′, but the degree of which is largely dependent on the DBT reconstruction algorithm. For a filtered backprojection (FBP) algorithm with spectral apodization and slice-thickness filters, which dominate the blur for reconstructed images at oblique angles, the effect of oblique entry of x-rays on 3D d′ is minimal. Thus, increasing d{sub Se} results in an improvement in d′ for both CE-DM and CE-DBT with typical FBP reconstruction parameters. Conclusions: Increased d{sub Se} improves CE breast imaging performance by increasing QDE of detectors at higher energies, e.g., 49 kVp. Although there is additional blur in the oblique angled projections of a DBT scan, the overall 3D d′ for DBT is not degraded because the dominant source blur at these angles results from the reconstruction filters of the employed FBP algorithm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Racial Variations in Radiation-Induced Skin Toxicity Severity: Data From a Prospective Cohort Receiving Postmastectomy Radiation

Purpose: Radiation-induced skin toxicity is one of the most symptomatic side effects of postmastectomy radiation therapy (PMRT). We sought to determine whether the severity of acute skin toxicity was greater in black patients in a prospective cohort receiving PMRT and to identify other predictors of more severe skin toxicity. Methods and Materials: We evaluated the first 110 patients in an ongoing prospective study assessing radiation-induced skin toxicity in patients receiving PMRT. We recorded patient demographics, body mass index (BMI), and disease and treatment characteristics. Logistic regression analyses were conducted to evaluate the effect of potential predictors on the risk of skin toxicity. Results: A total of 23.6% respondents self-identified as black, 5.5% as non-Hispanic white, 69.1% as Hispanic white, and 1.8% as other; 57% were postmenopausal, and 70.9% had BMI of >25. Median chest wall dose was 50 Gy, and mastectomy scar dose was 60 Gy. Most patients, 95.5%, were treated with a 0.5-cm bolus throughout treatment. There were no significant differences in patient characteristics in black versus non-black patients. At RT completion, moist desquamation was more common in black patients (73.1% vs 47.6%, respectively, P=.023), in postmenopausal patients (63.5% vs 40.4%, respectively, P=.016), and in those with BMI of ≥25 (60.3% vs 37.5%, respectively, P=.030). On multivariate analysis, the effects of black race (odds ratio [OR] = 7.46, P=.031), BMI ≥25 (OR = 2.95, P=.043) and postmenopausal status (OR = 8.26, P=.004) remained significant risk factors for moist desquamation. Conclusions: In this prospectively followed, racially diverse cohort of breast cancer patients receiving PMRT delivered in a uniform fashion, including the routine use of chest wall boost and bolus, black race, higher BMI, and postmenopausal status emerged as significant predictors of moist desquamation. There was a high frequency of moist desquamation, particularly in those patients with elevated risk. Continued study of patient selection for chest wall boost and bolus as well improved skin toxicity management strategies are needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Al{sub 2}O{sub 3}/GeO{sub x} gate stack on germanium substrate fabricated by in situ cycling ozone oxidation method

Al{sub 2}O{sub 3}/GeO{sub x}/Ge gate stack fabricated by an in situ cycling ozone oxidation (COO) method in the atomic layer deposition (ALD) system at low temperature is systematically investigated. Excellent electrical characteristics such as minimum interface trap density as low as 1.9 × 10{sup 11 }cm{sup −2 }eV{sup −1} have been obtained by COO treatment. The impact of COO treatment against the band alignment of Al{sub 2}O{sub 3} with respect to Ge is studied by x-ray photoelectron spectroscopy (XPS) and spectroscopic ellipsometry (SE). Based on both XPS and SE studies, the origin of gate leakage in the ALD-Al{sub 2}O{sub 3} is attributed to the sub-gap states, which may be correlated to the OH-related groups in Al{sub 2}O{sub 3} network. It is demonstrated that the COO method is effective in repairing the OH-related defects in high-k dielectrics as well as forming superior high-k/Ge interface for high performance Ge MOS devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The tomato DWD motif-containing protein DDI1 interacts with the CUL4–DDB1-based ubiquitin ligase and plays a pivotal role in abiotic stress responses

Highlights: • We identify DDI1 as a DAMAGED DNA BINDING PROTEIN1 (DDB1)-interacting protein. • DDI1 interacts with the CUL4–DDB1-based ubiquitin ligase in the nucleus. • DDI1 plays a positive role in regulating abiotic stress response in tomato. - Abstract: CULLIN4(CUL4)–DAMAGED DNA BINDING PROTEIN1 (DDB1)-based ubiquitin ligase plays significant roles in multiple physiological processes via ubiquitination-mediated degradation of relevant target proteins. The DDB1–CUL4-associated factor (DCAF) acts as substrate receptor in the CUL4–DDB1 ubiquitin ligase complex and determines substrate specificity. In this study, we identified a tomato (Solanum lycopersicum) DDB1-interacting (DDI1) protein as a DCAF protein involved in response to abiotic stresses, including UV radiation, high salinity and osmotic stress. Co-immunoprecipitation and bimolecular fluorescence complementation assay indicated that DDI1 associates with CUL4–DDB1 in the nucleus. Quantitative RT-PCR analysis indicated the DDI1 gene is induced by salt, mannitol and UV-C treatment. Moreover, transgenic tomato plants with overexpression or knockdown of the DDI1 gene exhibited enhanced or attenuated tolerance to salt/mannitol/UV-C, respectively. Thus, our data suggest that DDI1 functions as a substrate receptor of the CUL4–DDB1 ubiquitin ligase, positively regulating abiotic stress response in tomato.

60 APPLIED LIFE SCIENCES↗

Effect of carbonate and phosphate ratios on the transformation of calcium orthophosphates

Graphical abstract: Complexes among phosphate, carbonate and calcium have been prepared via a facile hydrothermal route. The synthesized product at the low (0.15) and the high (1.8) molar ratio of PO{sub 4}{sup 3−}/CO{sub 3}{sup 2−} is calcium phosphate hydrate and hydroxylapatite (HAp), respectively. Molar ratios of PO{sub 4}{sup 3−}/CO{sub 3}{sup 2−} are effective on the reduction of carbonate activity during the crystallization of HAp. - Highlights: • Formation of different complexes from CO{sub 3}{sup 2−}, PO{sub 4}{sup 3−} and Ca{sup 2+} solutions at 60 °C. • Molar ratios of PO{sub 4}{sup 3−}/CO{sub 3}{sup 2} cause changes in phase and size of synthesized products. • Addition of PO{sub 4}{sup 3} inhibited the activity of CO{sub 3}{sup 2−} during bound with Ca{sup 2+}. • The phase transformation was completed, when CO{sub 3}{sup 2−} peaks disappeared in FTIR. • PO{sub 4}{sup 3−}, CO{sub 3}{sup 2−} and Ca{sup 2+} distributed heterogeneously on the surface of precipitation. - Abstract: Complexes among phosphate, carbonate and calcium have been synthesized by a designed hydrothermal method. Effects of carbonate and phosphate ratios on the transformation of calcium-orthophosphates were investigated. With X-ray diffraction measurement the synthesized product at the low (0.15) and the high (1.8) molar ratio of PO{sub 4}{sup 3−}/CO{sub 3}{sup 2−} is calcium phosphate hydrate at pH 9.0, and hydroxylapatite (HAp) at pH 8.0, respectively. Fourier transform infrared spectroscopy of product at the high ratio (1.8) of PO{sub 4}{sup 3−}/CO{sub 3}{sup 2−} shows that the CO{sub 3}{sup 2−} peaks disappear, and the strong peaks at 1412 and 1460 cm{sup −1} are assigned to the vibrations of PO{sub 4}{sup 3−} in HAp. {sup 31}P nuclear magnetic resonance spectra of products at the low (0.15–0.6) to the high (1.2–1.8) ratios of PO{sub 4}{sup 3−}/CO{sub 3}{sup 2−} are obtained at 2.9 and 2.7 ppm, respectively. Molar ratios of PO{sub 4}{sup 3−}/CO{sub 3}{sup 2−} are effective on the reduction of carbonate activity during the formation and infiltration events of calcium-phosphate surface precipitates, and are subsequently enclosed during HAp formation.

36 MATERIALS SCIENCE↗

Evaluation of a low-cost and accurate ocean temperature logger on subsurface mooring systems

Monitoring seawater temperature is important to understanding evolving ocean processes. To monitor internal waves or ocean mixing, a large number of temperature loggers are typically mounted on subsurface mooring systems to obtain high-resolution temperature data at different water depths. In this study, we redesigned and evaluated a compact, low-cost, self-contained, high-resolution and high-accuracy ocean temperature logger, TC-1121. The newly designed TC-1121 loggers are smaller, more robust, and their sampling intervals can be automatically changed by indicated events. They have been widely used in many mooring systems to study internal wave and ocean mixing. The logger’s fundamental design, noise analysis, calibration, drift test, and a long-term sea trial are discussed in this paper.

Internal waves, Ocean mixing, Temperature loggers,↗