Engineering Papers⌕ Search

Engineering topics

Zhao, Q.

Publications and source records attributed to Zhao, Q..

29 records · Page 2

Progress towards the Facility for Rare Isotope Beams

Muon-based facilities offer a unique potential to provide capabilities at both the Intensity Frontier with Neutrino Factories and the Energy Frontier with Muon Colliders ranging from the Higgs energy to the multi-TeV energy range. They rely on novel technology with challenging parameters, for which the feasibility is currently being assessed by the U.S. Muon Accelerator Program (MAP) [1]. A realistic scenario for a complementary series of staged facilities with increasing complexity and significant physics potential at each stage has been developed. It takes advantage of and leverages the capabilities already planned at Fermilab, especially Project X and LBNE. Each stage is defined in such a way as to provide an R&D platform to validate the technologies required for subsequent stages. The rationale and sequence of a realistic staging process are presented.

Wei, J.↗

RBS and PIXE analysis of chlorine contamination in ALD-Grown TiN films on silicon

The performance, strengths and limitations of RBS and PIXE for the characterization of trace amounts of Cl in TiN thin films are critically compared. The chlorine atomic concentration in ALD grown TiN thin films on Si is determined for samples grown at temperatures ranging from 350 Degree-Sign C to 550 Degree-Sign C. We show that routine Rutherford backscattering spectrometry measurements (1.5 MeV He{sup +}) and PIXE measurements (1.5 MeV H{sup +}) on 20 nm thick TiN films allow one to determine the Cl content down to 0.3 at% with an absolute statistical accuracy reaching 0.03 at%. Possible improvements to push the sensitivity limit for both approaches are proposed.

36 MATERIALS SCIENCE↗

Report on Design, Development, and Characterization of a Coaxial Resonator Based Single-gap Gridless Multiharmonic Buncher

The design of the multiharmonic buncher is determined by Facility for Rare Isotope Beam (FRIB) requirements. The buncher will bunch stable ion beams for injection into the FRIB RFQ to minimize the longitudinal beam emittance growth. The design beam energy is fixed at 12 keV/u while the beam charge state Q/A can vary from 1/3 to 1/7. The buncher operates at a fundamental frequency of 40.25 MHz. Two higher harmonics, 80.5 MHz and 120.75 MHz are used to linearize the voltage ramp. The typical accelerating voltage for a uranium beam, including the time-of-flight factor, is 1271 V, 456 V, and 150 V for 40.25 MHz, 80.5 MHz, and 120.75 MHz harmonics respectively. The voltage will be scaled with the charge state of an accelerated beam. The accelerated electrical beam current is expected to be approximately equal to 0.5 mA for all ion beams between oxygen and uranium.

43 PARTICLE ACCELERATORS↗

BEAM SIMULATIONS USING VIRTUAL DIAGNOSTICS FOR THE DRIVER LINAC

End-to-end beam simulations for the driver linac have shown that the design meets the necessary performance requirements including having adequate transverse and longitudinal acceptances. However, to achieve reliable operational performance, the development of appropriate beam diagnostic systems and control room procedures are crucial. With limited R&D funding, beam simulations provide a cost effective tool to evaluate candidate beam diagnostic systems and to provide a critical basis for developing early commissioning and later operational activities. We propose to perform beam dynamic studies and engineering analyses to define the requisite diagnostic systems of the driver linac and through simulation to develop and test commissioning and operational procedures.

43 PARTICLE ACCELERATORS↗

A Model for Backscattering from Quasi Periodic Corn Canopies at L-Band

In this study, a model for backscattering at L-band from a corn canopy is proposed. The canopy consists of a quasi-periodic distribution of stalks and a random distribution of leaves. The Distorted Born Approximation (DBA) is employed to calculate the single scattered return from the corn field. The new feature of the method is that the coherence of the stalks in the row direction is incorporated in the model in a systematic fashion. Since the wavelength is on the order of the distance between corn stalks in a row, grating lobe behavior is observed at certain azimuth angles of incidence. The results are compared with experimental values measured in Huntsville, Alabama in 1998. The mean field and the effective dielectric constant of the canopy are obtained by using the Foldy approximation. The stalks are placed in the effective medium in a two dimensional lattice to simulate the row structure of a corn field. In order to mimic a real corn field, a quasi-periodic stalk distribution is assumed where the stalks are given small random perturbations about their lattice locations. Corn leaves are also embedded in the effective medium and the backscattered field from the stalks and the leaves is computed. The backscattering coefficient is calculated and averaged over successive stalk position perturbations. It is assumed that soil erosion has smoothed the soil sufficiently so that it can be assumed flat. Corn field backscatter data was collected from cornfields during the Huntsville 98 experimental campaign held at Alabama A&M University Research Station, Huntsville, Alabama in 1998 using the NASA/GW truck mounted radar. Extensive ground truth data was collected. This included soil moisture measurements and corn plant architectural data to be used in the model. In particular, the distances between the stalks in a single row have been measured. The L-band radar backscatter data was collected for both H and V polarizations and for look angles of 15o and 45o over a two week period under varying soil moisture conditions. These measured backscattering values will be compared with the model backscattering values and a discussion of the results will be presented.

Lang, R.↗

Dosimetric characteristics of a single use MOSFET dosimeter for in vivo dosimetry in proton therapy

Purpose: Entrance dose (or skin dose) is an important part of patient quality assurance in external beam radiation therapy. However, entrance dose verification in proton beam is not routinely performed. In this study, the OneDose single use MOSFET detector system for in vivo dosimetry measurement in proton therapy is investigated. Methods: Using a solid water phantom, several fundamental dosimetric characteristics of the OneDose system are studied with a proton beam: The reproducibility (consistency) of the dosimeter, the linearity with dose and dose rate, energy dependence, directional dependence, LET dependence, and fading (delay readout with time) is studied. Results: OneDose detectors show dose and dose rate linearity but exhibit pronounced energy dependence at depth and a large variation in dose response with LET. On the other hand, the detector response remain relatively constant (within 3%) at surface over a wide range of energies. There is also a slight angular dependence (about 2%) up to 60 deg. angle of incidence. However, detector orientation such that incidence along the long axis of the detector should be avoided as the proton beam will have to traverse a large amount of the copper backing. Since most in vivo dosimetry involves entrance dose measurement, the OneDose at surface appears to be well suited for such application. OneDose exhibits small intrabatch variation ({<=}2% at one SD) indicating that it is only necessary to calibration a few detectors from each batch. The interbatch variation is generally within 3%. Conclusions: The small detector size and its relatively flexible design of OneDose allow dose measurement to be performed on a curved surface or in small cavities that is otherwise difficult with the conventional diode detectors. The slight drawback in its angular dependence can be easily handled by angular dependence table. However, since OneDose is a single use detector, the intrabatch consistency must be verified before the remaining detectors from the same batch could be used for in vivo dosimetry. It is advisable that the detectors from the same batch be taken for the same application to reduce the dosimetric uncertainty. For detectors from different batches, interbatch consistency should also be verified to obtain reliable results. OneDose provides an opportunity to measure in vivo dose with proton beam within acceptable clinical criterion of {+-}(5.0%-6.5%).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam Loss Studies for Rare Isotope Driver Linacs Final Report

The Fortran 90 RIAPMTQ/IMPACT code package is a pair of linked beam-dynamics simulation codes that have been developed for end-to-end computer simulations of multiple-charge-state heavy-ion linacs for future exotic-beam facilities. These codes have multiple charge-state capability, and include space-charge forces. The simulations can extend from the low-energy beam-transport line after an ECR ion source to the end of the linac. The work has been performed by a collaboration including LANL, LBNL, ANL, and MSU. The code RIAPMTQ simulates the linac front-end beam dynamics including the LEBT, RFQ, and MEBT. The code IMPACT simulates the beam dynamics of the main superconducting linac. The codes have been benchmarked for rms beam properties against previously existing codes at ANL and MSU. The codes allow high-statistics runs on parallel supercomputing platforms, particularly at NERSC at LBNL, for studies of beam losses. The codes also run on desktop PC computers for low-statistics work. The code package is described in more detail in a recent publication [1] in the Proceedings of PAC07 (2007 US Particle Accelerator Conference). In this report we describe the main activities for the FY07 beam-loss studies project using this code package.

43 PARTICLE ACCELERATORS↗

Stretching and unzipping nucleic acid hairpins using a synthetic nanopore

We have explored the electromechanical properties of DNA by using an electric field to force single hairpin molecules to translocate through a synthetic pore in a silicon nitride membrane. We observe a threshold voltage for translocation of the hairpin through the pore that depends sensitively on the diameter and the secondary structure of the DNA. The threshold for a diameter 1.5 < d < 2.3 nm is V > 1.5 V, which corresponds to the force required to stretch the stem of the hairpin, according to molecular dynamics simulations. On the other hand, for 1.0 < d < 1.5 nm, the threshold voltage collapses to V < 0.5 V because the stem unzips with a lower force than required for stretching. The data indicate that a synthetic nanopore can be used like a molecular gate to discriminate between the secondary structures in DNA.

59 BASIC BIOLOGICAL SCIENCES↗