Engineering Papers⌕ Search

Engineering topics

Zhao, Feng

Publications and source records attributed to Zhao, Feng.

At least 55 records · Page 3

Polysulfide-Shuttle Control in Lithium-Sulfur Batteries with a Chemically/Electrochemically Compatible NaSICON-Type Solid Electrolyte

A NaSICON–type Li + –ion conductive membrane with a formula of Li 1+ x Y x Zr 2– x (PO 4 ) 3 (LYZP) (x = 0–0.15) has been explored as a solid–electrolyte/separator to suppress polysulfide–crossover in lithium–sulfur (Li–S) batteries. Here, the LYZP membrane with a reasonable Li + –ion conductivity shows both favorable chemical compatibility with the lithium polysulfide species and exhibits good electrochemical stability under the operating conditions of the Li–S batteries. Through an integration of the LYZP solid electrolyte with the liquid electrolyte, the hybrid Li–S batteries show greatly enhanced cyclability in contrast to the conventional Li–S batteries with the porous polymer (e.g., Celgard) separator. At a rate of C/5, the hybrid Li ||LYZP|| Li 2 S 6 batteries developed in this study (with a Li–metal anode, a liquid/LYZP hybrid electrolyte, and a dissolved lithium polysulfide cathode) delivers an initial discharge capacity of ≈1000 mA h g –1 (based on the active sulfur material) and retains ≈90% of the initial capacity after 150 cycles with a low capacity fade–rate of <0.07% per cycle.

25 ENERGY STORAGE↗

LYATK1 potently inhibits LPS-mediated pro-inflammatory response

Lipopolysaccharide (LPS)-primed monocytes/macrophages produce pro-inflammatory cytokines, which could lead to endotoxin shock. TGF-β-activated kinase1 (TAK1) activation is involved in the process. In the current study, we studied the potential effect of a selective TAK1 inhibitor, LYTAK1, on LPS-stimulated response both in vitro and in vivo. We demonstrated that LYTAK1 inhibited LPS-induced mRNA expression and production of several pro-inflammatory cytokines [interleukin 1β (IL-1β), tumor necrosis factor-α (TNFα) and interleukin-6 (IL-6)] in RAW 264.7 macrophages. LYTAK1's activity was almost nullified with TAK1 shRNA-knockdown. Meanwhile, in both primary mouse bone marrow derived macrophages (BMDMs) and human peripheral blood mononuclear cells (PBMCs), LPS-induced pro-inflammatory cytokine production was again attenuated with LYTAK1 co-treatment. Molecularly, LYTAK1 dramatically inhibited LPS-induced TAK1-nuclear factor kappa B (NFκB) and mitogen-activated protein kinase (Erk, Jnk and p38) activation in RAW 264.7 cells, mouse BMDMs and human PBMCs. In vivo, oral administration of LYTAK1 inhibited LPS-induced activation of TAK1-NFκB-p38 in ex-vivo cultured PBMCs, and cytokine production and endotoxin shock in mice. Together, these results demonstrate that LYTAK1 inhibits LPS-induced production of several pro-inflammatory cytokines and endotoxin shock probably through blocking TAK1-regulated signalings. - Highlights: • LYTAK1 inhibits LPS-induced pro-inflammatory cytokine production in RAW 264.7 cells. • The effect by LYTAK1 is more potent than other known TAK1 inhibitors. • LYTAK1 inhibits LPS-induced cytokine production in primary macrophages/monocytes. • LYTAK1 inhibits LPS-induced TAK1-NFκB and MAPK activation in macrophages/monocytes. • LYTAK1 gavage inhibits LPS-induced endotoxin shock and cytokine production in mice.

60 APPLIED LIFE SCIENCES↗

WFIRST-AFTA Overview Technology needs summary Mirror Technology Conference 2015

Presentation covers the overview of the science and hardware of the WFIRST-AFTA (Wide-Field Infrared Survey Telescope) (Astrophysics Focused Telescope Assets) mission. It includes an overview of the technology, with an emphasis on optics technology. It also introduces the WFIRST talks that come later, one on the Wide Field Instrument filters and the other on the CoronaGraph Instrument.

Infared Telescopes↗

WFIRST-AFTA Presentation to the NRC Mid-Decadal Panel

Over the past two years, increased funding has enabled significant progress in technology matura1on as well as addi1onal fidelity in the design reference mission. WFIRST with the 2.4-­‐m telescope and coronagraph provides an exci1ng science program, superior to that recommended by NWNH and also advances exoplanet imaging technology (the highest ranked medium-­‐class NWNH recommenda1on). Great opportunity for astronomy and astrophysics discoveries. Broad community support for WFIRST. Key development areas are anchored in a decade of investments in JPL's HCIT and GSFC's DCL. Great progress made in pre-­‐formula1on, ready for KDP-­‐A and launch in mid-­‐2020s.

Astronomy↗

Regional Rates of Young US Forest Growth Estimated From Annual Landsat Disturbance History and IKONOS Stereo Imagery

Forests of the Contiguous United States (CONUS) have been found to be a large contributor to the global atmospheric carbon sink. The magnitude and nature of this sink is still uncertain and recent studies have sought to define the dynamics that control its strength and longevity. The Landsat series of satellites has been a vital resource to understand the long-term changes in land cover that can impact ecosystem function and terrestrial carbonstock. We combine annual Landsat forest disturbance history from 1985 to 2011 with single date IKONOS stereoimagery to estimate the change in young forest canopy height and above ground live dry biomass accumulation for selected sites in the CONUS. Our approach follows an approximately linear growth rate following clearing over short intervals and does not estimate the distinct non-linear growth rate over longer intervals.We produced canopy height models by differencing digital surface models estimated from IKONOS stereo pairs with national elevation data (NED). Correlations between height and biomass were established independently using airborne LiDAR, and then applied to the IKONOS-estimated canopy height models. Graphing current biomass against time since disturbance provided biomass accumulation rates. For 20 study sites distributed across five regions of the CONUS, 19 showed statistically significant recovery trends (p is less than 0.001) with canopy growth from 0.26 m yr-1to 0.73 m yr-1. Above ground live dry biomass (AGB) density accumulation ranged from 1.31 t/ha yr-1 to 12.47 t/ha yr-1. Mean forest AGB accumulationwas 6.31 t/ha yr-1 among all sites with significant growth trends. We evaluated the accuracy of our estimates by comparing to field estimated site index curves of growth, airborne LiDAR data, and independent model predictions of C accumulation. Growth estimates found with this approach are consistent with site index curves and total biomass estimates fall within the range of field estimates. This is aviable approach to estimate forest biomass accumulation in regions with clear-cut harvest disturbances.

Neigh, Christopher S. R.↗

Deciphering the Precision of Stereo IKONOS Canopy Height Models for U.S. Forests with G-LiHT Airborne LiDAR

Few studies have evaluated the precision of IKONOS stereo data for measuring forest canopy height. The high cost of airborne light detection and ranging (LiDAR) data collection for large area studies and the present lack of a spaceborne instrument lead to the need to explore other low cost options. The US Government currently has access to a large archive of commercial high-resolution imagery, which could be quite valuable to forest structure studies. At 1 m resolution, we here compared canopy height models (CHMs) and height data derived from Goddard's airborne LiDAR Hyper-spectral and Thermal Imager (G-LiHT) with three types of IKONOS stereo derived digital surface models (DSMs) that estimate CHMs by subtracting National Elevation Data (NED) digital terrain models (DTMs). We found the following in three different forested regions of the US after excluding heterogeneous and disturbed forest samples: (1) G-LiHT DTMs were highly correlated with NED DTMs with R (sup 2) greater than 0.98 and root mean square errors (RMSEs) less than 2.96 m; (2) when using one visually identifiable ground control point (GCP) from NED, G-LiHT DSMs and IKONOS DSMs had R (sup 2) greater than 0.84 and RMSEs of 2.7 to 4.1 m; and (3) one GCP CHMs for two study sites had R (sup 2) greater than 0.7 and RMSEs of 2.6 to 3 m where data were collected less than four years apart. Our results suggest that IKONOS stereo data are a useful LiDAR alternative where high-quality DTMs are available.

IKONOS↗

A Comparison of Foliage Profiles in the Sierra National Forest Obtained with a Full-Waveform Under-Canopy EVI Lidar System with the Foliage Profiles Obtained with an Airborne Full-Waveform LVIS Lidar System

Foliage profiles retrieved froma scanning, terrestrial, near-infrared (1064 nm), full-waveformlidar, the Echidna Validation Instrument (EVI), agree well with those obtained from an airborne, near-infrared, full-waveform, large footprint lidar, the Lidar Vegetation Imaging Sensor (LVIS). We conducted trials at 5 plots within a conifer stand at Sierra National Forest in August, 2008. Foliage profiles retrieved from these two lidar systems are closely correlated (e.g., r = 0.987 at 100 mhorizontal distances) at large spatial coverage while they differ significantly at small spatial coverage, indicating the apparent scanning perspective effect on foliage profile retrievals. Alsowe noted the obvious effects of local topography on foliage profile retrievals, particularly on the topmost height retrievals. With a fine spatial resolution and a small beam size, terrestrial lidar systems complement the strengths of the airborne lidars by making a detailed characterization of the crowns from a small field site, and thereby serving as a validation tool and providing localized tuning information for future airborne and spaceborne lidar missions.

Full-waveform↗

Efficient reversible electrodes for solid oxide electrolyzer cells

An electrolyzer cell is disclosed which includes a cathode to reduce an oxygen-containing molecule, such as H2O, CO.sub.2, or a combination thereof, to produce an oxygen ion and a fuel molecule, such as H.sub.2, CO, or a combination thereof. An electrolyte is coupled to the cathode to transport the oxygen ion to an anode. The anode is coupled to the electrolyte to receive the oxygen ion and produce oxygen gas therewith. In one embodiment, the anode may be fabricated to include an electron-conducting phase having a perovskite crystalline structure or structure similar thereto. This perovskite may have a chemical formula of substantially (Pr(.sub.1-x)La.sub.x)(z-y)A&#x27;.sub.yBO(3-.differential.), wherein 0<x<1, 0.ltoreq.y.ltoreq.0.5, and 0.8.ltoreq.z.ltoreq.1.1. In another embodiment, the cathode includes an electron-conducting phase that contains nickel oxide intermixed with magnesium oxide.

42 ENGINEERING↗

Measuring Gap Fraction, Element Clumping Index and LAI in Sierra Forest Stands Using a Full-Waveform Ground-Based Lidar

The Echidna Validation Instrument (EVI), a ground-based, near-infrared (1064 nm) scanning lidar, provides gap fraction measurements, element clumping index measurements, effective leaf area index (LAIe) and leaf area index (LAI) measurements that are statistically similar to those from hemispherical photos. In this research, a new method integrating the range dimension is presented for retrieving element clumping index using a unique series of images of gap probability (Pgap) with range from EVI. From these images, we identified connected gap components and found the approximate physical, rather than angular, size of connected gap component. We conducted trials at 30 plots within six conifer stands of varying height and stocking densities in the Sierra National Forest, CA, in August 2008. The element clumping index measurements retrieved from EVI Pgap image series for the hinge angle region are highly consistent (R2=0.866) with those of hemispherical photos. Furthermore, the information contained in connected gap component size profiles does account for the difference between our method and gap-size distribution theory based method, suggesting a new perspective to measure element clumping index with EVI Pgap image series and also a potential advantage of three dimensional Lidar data for element clumping index retrieval. Therefore further exploration is required for better characterization of clumped condition from EVI Pgap image series.

Zhao, Feng↗

Laser Truss Sensor for Segmented Telescope Phasing

A paper describes the laser truss sensor (LTS) for detecting piston motion between two adjacent telescope segment edges. LTS is formed by two point-to-point laser metrology gauges in a crossed geometry. A high-resolution (<30 nm) LTS can be implemented with existing laser metrology gauges. The distance change between the reference plane and the target plane is measured as a function of the phase change between the reference and target beams. To ease the bandwidth requirements for phase detection electronics (or phase meter), homodyne or heterodyne detection techniques have been used. The phase of the target beam also changes with the refractive index of air, which changes with the air pressure, temperature, and humidity. This error can be minimized by enclosing the metrology beams in baffles. For longer-term (weeks) tracking at the micron level accuracy, the same gauge can be operated in the absolute metrology mode with an accuracy of microns; to implement absolute metrology, two laser frequencies will be used on the same gauge. Absolute metrology using heterodyne laser gauges is a demonstrated technology. Complexity of laser source fiber distribution can be optimized using the range-gated metrology (RGM) approach.

Liu, Duncan T.↗