Engineering PapersSearch

Engineering topics

Zhang, Z.

Publications and source records attributed to Zhang, Z..

Navigating the Path to Autonomy: Real-World Lessons from an Air-Free Self-Driving Laboratory

While autonomous experimentation has promise to accelerate discovery in physcial sciences, the real-world integration of predictive models and experimentation is non-trivial. Here we describe the genesis of a self-driving laboratory (SDL) for air-sensitive chemistry at Argonne National Laboratory and demonstrate the experimental design considerations needed for high-throughput experiments before predictive models can lead to scientific discovery. Our SDL was designed to explore battery electrolyte stability. Our final SDL utilized plate readers in a glovebox with a nitrogen atmosphere to perform kinetic assays and screen hundreds of battery-relevant solvents. However, the roadmap to autonomy and airfree-friendly experimentation required the complex evaluation of several spectroscopic and chromatographic methods. The greatest experimental challenges were (a) developing long-term sampling methods that remained air-free; (b) accelerating kinetics to advance reactivity projections; and (c) ensuring labware compatibility with nonaqueous solvents used in battery chemistry. Our experiences highlight the practical gap between closed-loop aspirations and the realities of chemical discovery, offering lessons on the challenges of transferring every day laboratory workflows to autonomy. These results suggest a more realistic blueprint for autonomy in chemistry—one that balances thoughtful and realistic experimental formulation.

Robertson, Lily A.

A dual dynamic shutter system for accelerating ion irradiation sample throughput via lateral gas implantation gradients

Ion irradiation for material performance testing is limited due to its serial nature, which allows for only one value of the implantation (appm) versus dose (dpa) parameter space to be explored for each ion and experiment at a time. While ion irradiation can accelerate the process by up to three orders of magnitude compared to neutron irradiation experiments, the sample throughput for ion irradiation remains relatively low. To address these limitations, a novel capability has been developed at the Michigan Ion Beam Laboratory (MIBL), enabling for the creation of single- and two-dimensional lateral ion implantation gradients using recently installed motorized-controlled ion-beam shutters. This advancement can generate a wide scope of the two-dimensional (H+, He2+) implantation parameter space within a single sample. Integration of this new capability now allows for dual- and triple-ion beam experiments to be performed with full user control over not only the ion implantation depth, but also laterally across the sample by imposing ion implantation concentration gradients, thus providing researchers with a high-throughput means for material testing under various irradiation conditions. Furthermore, recent improvements in MIBL's microbeam ion-beam analysis (IBA) target station now allow for probing these concentration gradients in irradiated alloys with exceptional spatial resolution, down to 10 µm. These two approaches promise to significantly improve ion irradiation capabilities and increase the sample throughput by several orders of magnitude. The application of the shutter technique plus the subsequent microbeam characterization of the imposed implantation gradients are showcased by two proof-of-principle ion-irradiated experiments, one performed on single-crystal Si and the other on the fusion-candidate alloy F82H-IEA. These advancements mark a substantial leap in ion-beam technology, offering researchers a robust, high-throughput method to efficiently investigate candidate alloys with high technological readiness for both advanced fission and fusion reactor applications, in a time- and cost-effective manner.

36 - MATERIALS SCIENCE

The DECADE cosmic shear project I: A new weak lensing shape catalog of 107 million galaxies

We present the Dark Energy Camera All Data Everywhere (DECADE) weak lensing dataset: a catalog of 107 million galaxies observed by the Dark Energy Camera (DECam) in the northern Galactic cap. This catalog was assembled from public DECam data including survey and standard observing programs. These data were consistently processed with the Dark Energy Survey Data Management pipeline as part of the DECADE campaign and serve as the basis of the DECam Local Volume Exploration survey (DELVE) Early Data Release 3 (EDR3). We apply the Metacalibration measurement algorithm to generate and calibrate galaxy shapes. After cuts, the resulting cosmology-ready galaxy shape catalog covers a region of $5,\!412 \,\,{\rm deg}^2$ with an effective number density of $4.59\,\, {\rm arcmin}^{-2}$. The coadd images used to derive this data have a median limiting magnitude of $r = 23.6$, $i = 23.2$, and $z = 22.6$, estimated at ${\rm S/N} = 10$ in a 2 arcsecond aperture. We present a suite of detailed studies to characterize the catalog, measure any residual systematic biases, and verify that the catalog is suitable for cosmology analyses. In parallel, we build an image simulation pipeline to characterize the remaining multiplicative shear bias in this catalog, which we measure to be $m = (-2.454 \pm 0.124) \times10^{-2}$ for the full sample. Despite the significantly inhomogeneous nature of the data set, due to it being an amalgamation of various observing programs, we find the resulting catalog has sufficient quality to yield competitive cosmological constraints.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Integration of the FastIC front-end electronics into the Picosec MicroMegas detector

The Picosec MicroMegas collaboration aims to develop gaseous fast-timing detectors; experimentally, intrinsic time resolutions from around 50 ps to better than 20 ps are obtained, depending on the exact detector configuration. Parts of developments focus on exploring various options of fast-timing multi-channel front-end electronics, to meet the data processing demands of experimental applications. One option is the FastIC, which was developed for reading out positive and negative input polarity sensors with intrinsic amplification. In this paper, the first results from reading out the gaseous Picosec MicroMegas detector with the FastIC are presented. In laboratory studies, a basic description of the data processing chain was performed using a function generator. The results from test beam measurements are used to characterise the timing performance and the charge processing of the combination of FastIC and Picosec MicroMegas, as well as to demonstrate the possibility of a multi-channel detector readout. Although the timing-at-threshold level of the FastIC introduces a time walk of around 1.5 ns, time resolutions of around 50 ps have been achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND