Engineering Papers⌕ Search

Engineering topics

Zhang, X.

Publications and source records attributed to Zhang, X..

At least 109 records · Page 6

Report on the completion of the development of processing map from as-cast Alloy 709 materials

This report provides details on the completion of the development of the processing map from the as-cast Alloy 709 materials. The report is a Level 4 deliverable in FY18 (M4NT18AN050502012), under the Work Package NT-18AN05050201, “A709 Development” performed by Argonne National Laboratory, as part of Advanced Structural Materials Program for the Advanced Reactor Technologies (ART). The report describes the development of a processing map to guide the development of hot work regimens for A709. The maps combine high-temperature flow stress measurements, described in a companion report by Oak Ridge National Laboratory, and metallographic observations, described here, into a single diagram that can be used to select hot working parameters to avoid regions of plastic instability and to avoid the development of unfavorable microstructures. This report describes the process of creating the map, provides the final map for A709, and uses the processing map to describe two potential hot work regimens that could be used in processing a DOE round ingot into bar stock.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Performance of a segmented 6 Li-loaded liquid scintillator detector for the PROSPECT experiment

This study describes the design and performance of a 50 liter, two-segment 6 Li-loaded liquid scintillator detector that was designed and operated as prototype for the PROSPECT (Precision Reactor Oscillation and Spectrum) Experiment. The two-segment detector was constructed according to the design specifications of the experiment. It features low-mass optical separators, an integrated source and optical calibration system, and materials that are compatible with the 6 Li-doped scintillator developed by PROSPECT. We demonstrate a high light collection of 850±20 PE/MeV, an energy resolution of σ = 4.0±0.2% at 1 MeV, and efficient pulse-shape discrimination of low dE/dx (electronic recoil) and high dE/dx (nuclear recoil) energy depositions. An effective scintillation attenuation length of 85±3 cm is measured in each segment. The 0.1% by mass concentration of 6 Li in the scintillator results in a measured neutron capture time of τ = 42.8±0.2 μs. The long-term stability of the scintillator is also discussed. Finally, the detector response meets the criteria necessary for achieving the PROSPECT physics goals and demonstrates features that may find application in fast neutron detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nugget Structure Evolution with Rotation Speed for High-Rotation-Speed Friction-Stir-Welded 6061 Aluminum Alloy

High-rotation-speed friction stir welding (HRS-FSW) is a promising technique to reduce the welding loads during FSW and thus facilitates the application of FSW for in situ fabrication and repair. In this study, 6061 aluminum alloy was friction stir welded at high-rotation speeds ranging from 3000 to 7000 rpm at a fixed welding speed of 50 mm/min, and the effects of rotation speed on the nugget zone macro- and microstructures were investigated in detail in order to illuminate the process features. Temperature measurements during HRS-FSW indicated that the peak temperature did not increase consistently with rotation speed; instead, it dropped remarkably at 5000 rpm because of the lowering of material shear stress. The nugget size first increased with rotation speed until 5000 rpm and then decreased due to the change of the dominant tool/workpiece contact condition from sticking to sliding. At the rotation speed of 5000 rpm, where the weld material experienced weaker thermal effect and higher-strain-rate plastic deformation, the nugget exhibited relatively small grain size, large textural intensity, and high dislocation density. Consequently, the joint showed superior nugget hardness and simultaneously a slightly low tensile ductility.

36 MATERIALS SCIENCE↗

Micro-Thin Lens Final Report CRADA No. TC-0331-92

The general objective of the CRADA was to develop ophthalmic optical elements that are so thin that they can be placed on the human eye in revolutionary new ways. More .specifically,the major accomplishment of this CRADA was to study the feasability of producing a prototype optical element in the form of a bifocal contact lens, for presbyopic vision correction.

59 BASIC BIOLOGICAL SCIENCES↗

Determination of spin relaxation times in heavy metals via second-harmonic spin injection magnetoresistance

In tunnel junctions between ferromagnets and heavy elements with strong spin orbit coupling the magnetoresistance is usually dominated by tunneling anisotropic magnetoresistance (TAMR). This makes conventional DC spin injection techniques impractical for determining the spin relaxation time τ s . Here, we show that this obstacle for measurements of τ s can be overcome by second-harmonic spin-injection magnetoresistance (SIMR). In the second-harmonic signal the SIMR is comparable in magnitude to TAMR, thus enabling Hanle-induced SIMR as a powerful tool to directly determine τ s . Using this approach we determined the spin relaxation time of Pt and Ta and their temperature dependences. In conclusion, the spin relaxation in Pt seems to be governed by the Elliott-Yafet mechanism due to a constant resistivity × spin relaxation time product over a wide temperature range.

36 MATERIALS SCIENCE↗

Direction-specific interaction forces underlying zinc oxide crystal growth by oriented attachment

Here, crystallization by particle attachment is impacting our understanding of natural mineralization processes and holds promise for novel materials design. When particles assemble in crystallographic registry, expulsion of the intervening solvent and particle coalescence is enabled by near-perfect co-alignment via interparticle forces that remain poorly quantified. Here we report measurement and simulation of these nanoscale aligning forces for the ZnO(0001)-ZnO(000¯1) system in aqueous solution. Dynamic force spectroscopy using nanoengineered single crystal probes reveals an attractive force with 60o rotational periodicity. Calculated distance and orientation-dependent potentials of mean force show several attractive free energy wells distinguished by numbers of intervening water layers, which reach a minimum when aligned. The calculated activation energy to separate the attractively bound solvated interfaces perfectly reproduces the measured 60o periodicity, revealing the key role of intervening water structuring as a basis to generate the interparticle torque that completes alignment and enables coalescence.

36 MATERIALS SCIENCE↗

Negative Differential Conductance & Hot-Carrier Avalanching in Monolayer WS2 FETs

The high field phenomena of inter-valley transfer and avalanching breakdown have long been exploited in devices based on conventional semiconductors. In this Article, we demonstrate the manifestation of these effects in atomically-thin WS 2 field-effect transistors. The negative differential conductance exhibits all of the features familiar from discussions of this phenomenon in bulk semiconductors, including hysteresis in the transistor characteristics and increased noise that is indicative of travelling high-field domains. It is also found to be sensitive to thermal annealing, a result that we attribute to the influence of strain on the energy separation of the different valleys involved in hot-electron transfer. This idea is supported by the results of ensemble Monte Carlo simulations, which highlight the sensitivity of the negative differential conductance to the equilibrium populations of the different valleys. At high drain currents (>10 μA/μm) avalanching breakdown is also observed, and is attributed to trap-assisted inverse Auger scattering. This mechanism is not normally relevant in conventional semiconductors, but is possible in WS 2 due to the narrow width of its energy bands. The various results presented here suggest that WS 2 exhibits strong potential for use in hot-electron devices, including compact high-frequency sources and photonic detectors.

36 MATERIALS SCIENCE↗

Layer thickness dependent strain rate sensitivity of Cu/amorphous CuNb multilayer

We report strain rate sensitivity of crystalline materials is closely related to dislocation activity. In the absence of dislocations, amorphous alloys are usually considered to be strain rate insensitive. However, the strain rate sensitivity of crystalline/amorphous composites is rarely studied, especially at nanoscale. In this study, we show that the strain rate sensitivity of Cu/amorphous CuNb multilayers is layer thickness dependent. At small layer thickness (below 50 nm), the multilayers demonstrate limited strain rate sensitivity; at relatively large layer thickness (above 100 nm), the strain rate sensitivity of multilayers is close to that of the single layer Cu film. Finally, mechanisms that lead to size dependent variation of strain rate sensitivity in these multilayers are discussed.

36 MATERIALS SCIENCE↗

Projected sensitivity of the SuperCDMS SNOLAB experiment

SuperCDMS SNOLAB will be a next-generation experiment aimed at directly detecting low-mass particles (with masses ≤ 10 GeV/c^2) that may constitute dark matter by using cryogenic detectors of two types (HV and iZIP) and two target materials (germanium and silicon). The experiment is being designed with an initial sensitivity to nuclear recoil cross sections ~1×10^-43 cm^2 for a dark matter particle mass of 1 GeV/c^2, and with capacity to continue exploration to both smaller masses and better sensitivities. The phonon sensitivity of the HV detectors will be sufficient to detect nuclear recoils from sub-GeV dark matter. A detailed calibration of the detector response to low-energy recoils will be needed to optimize running conditions of the HV detectors and to interpret their data for dark matter searches. Low-activity shielding, and the depth of SNOLAB, will reduce most backgrounds, but cosmogenically produced H-3 and naturally occurring Si-32 will be present in the detectors at some level. Even if these backgrounds are 10 times higher than expected, the science reach of the HV detectors would be over 3 orders of magnitude beyond current results for a dark matter mass of 1 GeV/c^2. The iZIP detectors are relatively insensitive to variations in detector response and backgrounds, and will provide better sensitivity for dark matter particles with masses ≳5 GeV/c^2. The mix of detector types (HV and iZIP), and targets (germanium and silicon), planned for the experiment, as well as flexibility in how the detectors are operated, will allow us to maximize the low-mass reach, and understand the backgrounds that the experiment will encounter. Upgrades to the experiment, perhaps with a variety of ultra-low-background cryogenic detectors, will extend dark matter sensitivity down to the “neutrino floor,” where coherent scatters of solar neutrinos become a limiting background.

Agnese, R.↗

Influence of injected interstitials on the void swelling in two structural variants of 304L stainless steel induced by self-ion irradiation at 500 °C

The two variants of AISI 304L stainless steel (SS) with different grain size distributions were ion irradiated at 500 °C to a peak dose of ~60 dpa. In the coarse-grained annealed variant, a peak swelling of ~12% was observed closer to the specimen surface rather than at the depth of peak displacement damage. The forward shift in depth between peak swelling and peak dose is proposed to be a consequence of suppression of void nucleation by injected interstitials. The swelling behavior in the front portion of the ion range mirrors that of neutron-induced swelling in this steel, exhibiting significant curvature with increasing dose as the swelling rate approaches the terminal swelling rate of 1%/dpa. Furthermore, an ultrafine grain variant of this steel produced by severely plastic deformation exhibits a similar suppression of void nucleation in the injected interstitial region, but also shows a significantly extended transient regime, not reaching the terminal swelling rate by 60 dpa.

304 stainless steel↗