Engineering Papers⌕ Search

Engineering topics

Zhang, X.

Publications and source records attributed to Zhang, X..

At least 235 records · Page 13

Structure of p53 binding to the BAX response element reveals DNA unwinding and compression to accommodate base-pair insertion

The p53 core domain binds to response elements (REs) that contain two continuous half-sites as a cooperative tetramer, but how p53 recognizes discontinuous REs is not well understood. Here we describe the crystal structure of the p53 core domain bound to a naturally occurring RE located at the promoter of the Bcl-2-associated X protein (BAX) gene, which contains a one base-pair insertion between the two half-sites. Surprisingly, p53 forms a tetramer on the BAX-RE that is nearly identical to what has been reported on other REs with a 0-bp spacer. Each p53 dimer of the tetramer binds in register to a half-site and maintains the same protein–DNA interactions as previously observed, and the two dimers retain all the protein–protein contacts without undergoing rotation or translation. To accommodate the additional base pair, the DNA is deformed and partially disordered around the spacer region, resulting in an apparent unwinding and compression, such that the interactions between the dimers are maintained. Furthermore, DNA deformation within the p53-bound BAX-RE is confirmed in solution by site-directed spin labeling measurements. Our results provide a structural insight into the mechanism by which p53 binds to discontinuous sites with one base-pair spacer.

59 BASIC BIOLOGICAL SCIENCES↗

Development of a new flux map processing code for moveable detector system in PWR

This paper presents an introduction to the development of the flux map processing code MAPLE developed by China Nuclear Power Technology Research Institute (CNPPJ), China Guangdong Nuclear Power Group (CGN). The method to get the three-dimensional 'measured' power distribution according to measurement signal has also been described. Three methods, namely, Weight Coefficient Method (WCM), Polynomial Expand Method (PEM) and Thin Plane Spline (TPS) method, have been applied to fit the deviation between measured and predicted results for two-dimensional radial plane. The measured flux map data of the LINGAO nuclear power plant (NPP) is processed using MAPLE as a test case to compare the effectiveness of the three methods, combined with a 3D neutronics code COCO. Assembly power distribution results show that MAPLE results are reasonable and satisfied. More verification and validation of the MAPLE code will be carried out in future. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Commissioning dose computation models for spot scanning proton beams in water for a commercially available treatment planning system

Purpose: To present our method and experience in commissioning dose models in water for spot scanning proton therapy in a commercial treatment planning system (TPS). Methods: The input data required by the TPS included in-air transverse profiles and integral depth doses (IDDs). All input data were obtained from Monte Carlo (MC) simulations that had been validated by measurements. MC-generated IDDs were converted to units of Gy mm{sup 2}/MU using the measured IDDs at a depth of 2 cm employing the largest commercially available parallel-plate ionization chamber. The sensitive area of the chamber was insufficient to fully encompass the entire lateral dose deposited at depth by a pencil beam (spot). To correct for the detector size, correction factors as a function of proton energy were defined and determined using MC. The fluence of individual spots was initially modeled as a single Gaussian (SG) function and later as a double Gaussian (DG) function. The DG fluence model was introduced to account for the spot fluence due to contributions of large angle scattering from the devices within the scanning nozzle, especially from the spot profile monitor. To validate the DG fluence model, we compared calculations and measurements, including doses at the center of spread out Bragg peaks (SOBPs) as a function of nominal field size, range, and SOBP width, lateral dose profiles, and depth doses for different widths of SOBP. Dose models were validated extensively with patient treatment field-specific measurements. Results: We demonstrated that the DG fluence model is necessary for predicting the field size dependence of dose distributions. With this model, the calculated doses at the center of SOBPs as a function of nominal field size, range, and SOBP width, lateral dose profiles and depth doses for rectangular target volumes agreed well with respective measured values. With the DG fluence model for our scanning proton beam line, we successfully treated more than 500 patients from March 2010 through June 2012 with acceptable agreement between TPS calculated and measured dose distributions. However, the current dose model still has limitations in predicting field size dependence of doses at some intermediate depths of proton beams with high energies. Conclusions: We have commissioned a DG fluence model for clinical use. It is demonstrated that the DG fluence model is significantly more accurate than the SG fluence model. However, some deficiencies in modeling the low-dose envelope in the current dose algorithm still exist. Further improvements to the current dose algorithm are needed. The method presented here should be useful for commissioning pencil beam dose algorithms in new versions of TPS in the future.

60 APPLIED LIFE SCIENCES↗

Compatibility of Lithium Salts with Solvent of the Non-Aqueous Electrolyte in Li–O 2 Batteries

The stability of lithium salts, especially in the presence of reduced oxygen species, O 2 and H 2 O (even in a small amount), plays an important role in the cyclability and capacity of Li–O 2 cells. This combined experimental and computational study provides evidence that the stability of the electrolyte used in Li–O 2 cells strongly depends on the compatibility of lithium salts with solvent. In the case of the LiPF 6 -1NM3 electrolyte, the decomposition of LiPF 6 occurs in the cell as evidenced by in situ XRD, FT-IR and XPS analysis, which triggers the decomposition of 1NM3 solvent due to formation of HF from the decomposition of LiPF 6 . These reactions lead to degradation of the electrolyte and cause poor cyclability of the cell. The same reactions are not observed when LiTFSI and LiCF 3 SO 3 are used as the lithium salts in 1NM3 solvent, or LiPF 6 is used in TEGDME solvent.

25 ENERGY STORAGE↗

Pine Pyrolysis Vapor Phase Upgrading Over ZSM-5 Catalyst: Effect of Temperature, Hot Gas Filtration, and Hydrogen Donor Molecule on the Rate of Deactivation of Catalyst

The conversion of primary vapors from pine pyrolysis over a ZSM-5 catalyst was characterized using a micro-reactor coupled to a molecular beam mass spectrometer (MBMS) to allow on-line measurement of the upgraded vapors. This micro-reacor-MBMS system was used to investigate the effects of hot gas filtration, temperature and hydrogen donor molecules on the rate of deactivation of the UPV2 catalyst. Our results show that the life of catalyst is significantly improved by using better filtration. Temperature had an effect on both product distribution and catalyst deactivation. The hydrogen donor molecules (HDM) used in this study show better reduction in catalyst deactivation rates at high temperatures.

09 BIOMASS FUELS↗

Theoretical Prediction and Experimental Realization of Missing Materials

Many chemically reasonable inorganic materials are missing from databases or literature. Two possible reasons are: (1) these materials are unstable; (2) they have been simply overlooked. Here we applied Inverse Design approach to systematically screen V-IX-IV group of 45 ternary ABX materials. High-throughput theory revealed 9 hitherto missing stable materials in this family. Combinatorial experiment synthesized one of them TaCoSn and discovered another one TaCo2Sn, the first two reported ternaries in this chemical system. This example illustrates the promise of computationally driven experimental inorganic materials chemistry.

36 MATERIALS SCIENCE↗

Synthesis and Optical Properties of NuTaN2: Potential Solar Cell Applications

Layered CuTaN2 was synthesized by an ion exchange reaction of CuI and NaTaN2 as previously reported. Based on the results of EDX analysis, the Cu:Ta ratio of the CuTaN2 sample was 1:1 within the overall errors when examining powders of +/-10% and no Na was detected. The crystal structure and thermal stability of CuTaN2 was accurately determined by Rietveld analysis of the powder X-ray Diffraction profile and by TGA analysis, respectively. CuTaN2 crystallizes in a rhombohedral structure with space group R-3mH as shown in [figure 1]. CuTaN2 possesses a band gap of 1.53(x) eV, which is in reasonable agreement with density functional theory calculations of Cu containing nitrides. Similar materials may be even better suited for solar cell application.

14 SOLAR ENERGY↗