pnnl/building-energy-standards-data
Database of building energy standards data for building energy simulation.
Engineering topics
Publications and source records attributed to Zhang, Jian.
Database of building energy standards data for building energy simulation.
Permanent magnets are of great importance due to their vast applications. MnBi has been proposed to be a potential permanent magnet that can be widely used while past efforts have been focused on optimizing the ferromagnetic low-temperature phase of MnBi. Herein, we report a series of new materials, Cu x Mn 1–x Bi, crystallizing in a quenched high-temperature-phase (QHTP) MnBi-related structure. In this study, we synthesized single crystals of Cu x Mn 1–x Bi and found that they crystallize in an unreported trigonal structure (P$\bar{3}$1c). Magnetic properties measurements imply high-temperature antiferromagnetic (AFM) ordering and low-temperature ferromagnetic or ferrimagnetic (FM/FiM) ordering. By analyzing the doping effect on crystal structure and magnetic properties, we established a magnetic phase diagram for Cu-doped MnBi and attributed the AFM and FM/FiM to two different atomic sites of Mn.
Not Available
Abstract The purification of p‐xylene (pX) from its xylene isomers represents a challenging but important industrial process. Herein, we report the efficient separation of pX from its ortho‐ and meta‐ isomers by a microporous calcium‐based metal–organic framework material (HIAM‐203) with a flexible skeleton. At 30 °C, all three isomers are accommodated but the adsorption kinetics of o‐xylene (oX) and m‐xylene (mX) are substantially slower than that of pX, and at an elevated temperature of 120 °C, oX and mX are fully excluded while pX can be adsorbed. Multicomponent column breakthrough measurements and vapor‐phase/liquid‐phase adsorption experiments have demonstrated the capability of HIAM‐203 for efficient separation of xylene isomers. Ab initio calculations have provided useful information for understanding the adsorption mechanism.
Here, the purification of p-xylene (pX) from its xylene isomers represents a challenging but important industrial process. Herein, we report the efficient separation of pX from its ortho- and meta- isomers by a microporous calcium-based metal–organic framework material (HIAM-203) with a flexible skeleton. At 30 °C, all three isomers are accommodated but the adsorption kinetics of o-xylene (oX) and m-xylene (mX) are substantially slower than that of pX, and at an elevated temperature of 120 °C, oX and mX are fully excluded while pX can be adsorbed. Multicomponent column breakthrough measurements and vapor-phase/liquid-phase adsorption experiments have demonstrated the capability of HIAM-203 for efficient separation of xylene isomers. Ab initio calculations have provided useful information for understanding the adsorption mechanism.
Recent research has shown the energy-saving potential of occupancy-based HVAC controls (OBCs) in commercial buildings. However, building energy codes have not fully adopted this technology. This study aims to evaluate the cost-effectiveness and decarbonization benefits of OBCs and provide guidance for integrating occupancy sensors into building energy code development. To this end, a parametric simulation using EnergyPlus and a nationwide cost-effectiveness analysis are carried out considering three building types and 40 representative cities in the U.S. Here, the findings reveal that the current cost-effectiveness performance of OBCs is limited due to the high cost of occupancy sensors. However, incorporating the societal cost of carbon factor in future energy and environmental policy could greatly enhance the actual cost-effectiveness performance. Besides, a reduction in the cost of occupancy sensors to approximately 60% of the current price level could also greatly shorten the discounted payback period of OBCs. Additionally, OBCs demonstrate significant potential in building decarbonization, with potential CO 2 emissions savings of more than 5.56 million metric tons across the three building types and 40 selected cities. Finally, policy implications are provided to guide the incorporation of occupancy-based HVAC controls in future energy codes.
Not Available
Despite the abundance of research applications of system modeling in grid-interactive efficient buildings (GEBs), the transfer of those applications to real-world practices is still in its early stages. This is partially due to the lack of a summary on how system modeling should be established for a given application of GEBs. Here, we fill this gap by providing an extensive survey of the literature on system modeling for different GEBs that have been produced in the past decade. This survey involves over 300 relevant journal articles from the building community, the power system community, and the society of control. Specifically, we first identified key requirements of system modeling for GEBs based on various types of applications discussed in those publications. We then summarized the system modeling applications from those publications, in terms of their assumptions, modeling approach, and simulation. After that, we analyzed different assumptions made for various applications, the extent to which those modeling approaches satisfied the key requirements, and how those approaches can be scaled up for large-scale applications, which are quite common in GEBs. In addition, we gave insights on how to use system modeling for different applications in GEBs. At the end, we provided recommended directions for future studies to fully unleash the potentials of system modeling to support GEBs.
Finding high performance plasma-facing materials (PFMs) is one of the most important and challenging tasks for realizing the commercial application of fusion reactors. Herein, we found the CrMoTaWV high entropy alloy (HEA) is highly resistant to low-energy and high-flux He plasma exposure. The nanochannel HEA film has 20 times higher initial fluence for the formation of fuzz and a remarkable 8.9 times slower fuzz growth rate than those of W. Combining the in-situ TEM observation and the Molecular dynamics (MD) simulation of the He bubble growth process, a new mechanism for the enhanced radiation resistance in HEA with the unusual interaction between HEA and He is found, where, differing from traditional metal, bubble growth in HEA leads to non-directional emission of interstitial atoms while HEA greatly suppress the growth of He bubbles. Additionally, the special nanochannel structure further rise the radiation resistance through releasing He out of the HEA film and reducing the He concentration. This new nanochannel refractory HEA material presents a promising choice as the PFMs with excellent performance and a much longer serving lifetime for future commercial fusion reactors.
Mastering nuclear fusion, which is an abundant, safe, and environmentally competitive energy, is a great challenge for humanity. Tokamak represents one of the most promising paths toward controlled fusion. Obtaining a high-performance, steady-state, and long-pulse plasma regime remains a critical issue. Recently, a big breakthrough in steady-state operation was made on the Experimental Advanced Superconducting Tokamak (EAST). A steady-state plasma with a world-record pulse length of 1056 s was obtained, where the density and the divertor peak heat flux were well controlled, with no core impurity accumulation, and a new high-confinement and self-organizing regime (Super I-mode = I-mode + e-ITB) was discovered and demonstrated. These achievements contribute to the integration of fusion plasma technology and physics, which is essential to operate next-step devices.
The Pacific Northwest National Laboratory, Oak Ridge National Laboratory, and the University of Minnesota conducted a three-year, multipart study on residential retrofit wall assemblies. The project, which was funded by the U.S. Department of Energy’s Building Technology Office, aimed to compare a range of residential wall retrofit systems that prioritized affordability, durability, and energy savings potential. The research team identified, constructed, tested, simulated, and analyzed the feasibility and economics of 16 wall retrofit assemblies (14 test configurations and two baseline configurations) that can be applied to the exterior side of existing walls (either with or without the existing cladding). The 16 wall assemblies were installed in an in-situ laboratory environment, to evaluate the ease of construction and study the thermal and hygrothermal performance of the walls. This paper presents the methodology used to evaluate the thermal performance of the walls and discusses the energy modeling results of the study. The results from the experiments were used to calibrate a THERM model of each wall assembly, which was then applied to a whole building using the EnergyPlus 8.6 simulation engine. A residential prototype building was used to extrapolate whole-building energy savings in each U.S. climate zone. To capture the conditions of the largest number of homes in the United States, the most frequent building characteristics (e.g., attic insulation level, window specifications, foundation insulation, etc.) were extracted from ResStock data and applied to the prototype model. Results from the energy modeling showed that the climate zones with the highest potential for retrofit savings are those which are heating-dominated (i.e., Cold and Very Cold climate designations). In these climate zones, heating and cooling energy savings due to the wall retrofits alone ranged from 21.5% to 38.2%.
In this study, we investigated modifications driven by 7,7,8,8-tetracyanoquinodimethane (TCNQ) to the spin state configuration of [Fe(3-bpp) 2 ](TCNQ) 2 co-crystal and both spin state and electric conductivity of [Fe{H 2 B(pz) 2 } 2 (bipy)] and TCNQ mixtures. The Fe 2+ site in the [Fe(3-bpp) 2 ](TCNQ) 2 co-crystal has a sizable orbital moment. During X-ray absorption measurements, the iron ion is partially excited to the high spin state and strong surface effects are indicated. Mixing TCNQ with the [Fe{H 2 B(pz) 2 } 2 (bipy)] spin crossover complex leads to a molecular combination with increased conductivity and drift carrier lifetimes. [Fe{H 2 B(pz) 2 } 2 (bipy)] thin films with TCNQ, grown using dimethylformamide (DMF), are to great extent locked mainly in the low spin (LS) state across a broad temperature range and exhibit drift carrier lifetimes approaching 0.5 s. When deposited onto a ferroelectric polyvinylidenefluoride-hexafluoropropylene thin film substrate, [Fe{H 2 B(pz) 2 } 2 (bipy)], shows enhanced transistor carrier mobility, likely associated with the increasing cationic character of [Fe{H 2 B(pz) 2 } 2 (bipy)] thin films with TCNQ.
Explore the source record for details and available documents.
Homes built before 1992, when the U.S. Department of Energy’s (DOE) Building Energy Codes Program was established, represent approximately 68% of the residential building stock in the country. Up to 43% of these homes have little to no insulation in the walls and have very high air leakage rates of 10 or more air changes per hour at 50 pascals of pressure (ACH50). These issues can represent a substantial portion of unnecessary money spent on utility bills for homeowners, especially in the colder climates. There is a significant need for cost-effective, reliable retrofit methods for these homes that include air, moisture, and vapor controls which are considered best practices for high-performance new home construction. Well-tested and documented wall retrofit systems can help to achieve substantial energy savings and also improve durability, comfort, health, and resilience. In 2018, DOE’s Building Technologies Office awarded Pacific Northwest National Laboratory, Oak Ridge National Laboratory, and the University of Minnesota funding to complete a 3-year project to compare a range of residential wall retrofit systems that prioritized affordability, durability and energy savings potential. In addition to these core criteria, the ease-of-construction and the wide-scale applicability of the solutions also were considered. In this project, the research team identified, constructed, tested, simulated, and analyzed the feasibility and economics of 16 wall retrofit assemblies (14 test configurations and two baseline configurations).
A novel microporous indium-based MOF material with unique 3-way rod-shaped secondary building units (SBUs), UTSA-22, was reported and exhibited high methane (CH 4 ) and hydrogen (H 2 ) storage. At 298 K and 65 bar, the total CH 4 volumetric uptake of UTSA-22 is 174 cm 3 (STP) cm -3 . Moreover, UTSA-22 shows a high CH 4 working capacity of 146 cm 3 (STP) cm -3 in a pressure range of 5–65 bar at 298 K. Additionally, UTSA-22 shows a high H 2 gravimetric storage capacity (1.2 wt%) at 298 K and 100 bar.
The Pr-rich end 0 ≤ x ≤ 0.25 of the alloy series Pr 1-x Nd x Os 4 Sb 12 has been studied using muon spin rotation and relaxation. The end compound PrOs 4 Sb 12 is an unconventional heavy-fermion superconductor, which exhibits a spontaneous magnetic field associated with broken time-reversal symmetry (TRS) in the superconducting phase. Further, no such field is observed in the Nd-doped alloys for x ≥ 0.05, indicating that TRS has been restored. The superfluid density from the vortex-lattice field distribution is insensitive to Nd concentration for x ≲ 0.2, indicating that TRS restoration does not have a strong effect on the superconducting state. No Nd 3+ static magnetism, ordered or disordered, is found down to the lowest temperatures of measurement.
Not Available
The United States building sector consumed approximately 75% of electricity in 2019. By implementing renewable energy technologies and control strategies into buildings, future buildings will serve as energy generators as well as consumers. To accommodate this transition, communications among buildings and between buildings and the grid could provide more possibilities to optimize the energy performance of buildings. This paper develops a community-scale building energy model tool and conducts a case study adopting behind-the-meter distributed energy resources, sharing energy in different buildings, and using different electricity tariff structures. Three scenarios are studied: (1) electricity only supplied by the grid, (2) photovoltaic (PV) panels installed on and available to some but not all buildings, and (3) a connected community. To consider the impacts of locations and energy tariffs, this paper selects four cities and three electricity tariffs to evaluate the energy and cost performances of these three scenarios. The results show that the PV panels in Scenario 2 reduce 25% to 33% of the community-level electricity consumption and 20% to 30% of the community-level electricity cost compared with Scenario 1 in all studied locations and energy tariffs. By considering power management in the connected community (Scenario 3), the electricity consumption and cost can be further reduced by 6% to 7% and 5% to 11%, respectively, compared with Scenario 2.