The response of a spherical tissue-equivalent proportional counter to iron particles from 200-1000 MeV/nucleon

The radiation environment on board the space shuttle and the International Space Station includes high-Z and high-energy (HZE) particles that are part of the galactic cosmic radiation (GCR) spectrum. Iron-56 particles are considered to be one of the most biologically important parts of the GCR spectrum. Tissue-equivalent proportional counters (TEPCs) are used as active dosimeters on manned space flights. These TEPCs are further used to determine the average quality factor for each space mission. A TEPC simulating a 1-microm-diameter sphere of tissue was exposed as part of a particle spectrometer to (56)Fe particles at energies from 200-1000 MeV/nucleon. The response of TEPCs in terms of mean lineal energy, y(F), and dose mean lineal energy, y(D), as well as the energy deposited at different impact parameters through the detector was determined for six different incident energies of (56)Fe particles in this energy range. Calculations determined that charged-particle equilibrium was achieved for each of the six experiments. Energy depositions at different impact parameters were calculated using a radial dose distribution model, and the results were compared to experimental data.

Non-NASA Center

Monte Carlo transport model comparison with 1A GeV accelerated iron experiment: heavy-ion shielding evaluation of NASA space flight-crew foodstuff

Deep-space manned flight as a reality depends on a viable solution to the radiation problem. Both acute and chronic radiation health threats are known to exist, with solar particle events as an example of the former and galactic cosmic rays (GCR) of the latter. In this experiment Iron ions of 1A GeV are used to simulate GCR and to determine the secondary radiation field created as the GCR-like particles interact with a thick target. A NASA prepared food pantry locker was subjected to the iron beam and the secondary fluence recorded. A modified version of the Monte Carlo heavy ion transport code developed by Zeitlin at LBNL is compared with experimental fluence. The foodstuff is modeled as mixed nuts as defined by the 71st edition of the Chemical Rubber Company (CRC) Handbook of Physics and Chemistry. The results indicate a good agreement between the experimental data and the model. The agreement between model and experiment is determined using a linear fit to ordered pairs of data. The intercept is forced to zero. The slope fit is 0.825 and the R2 value is 0.429 over the resolved fluence region. The removal of an outlier, Z=14, gives values of 0.888 and 0.705 for slope and R2 respectively. c2002 COSPAR. Published by Elsevier Science Ltd. All rights reserved.

NASA Discipline Radiation Health

Issues in deep space radiation protection

The exposures in deep space are largely from the Galactic Cosmic Rays (GCR) for which there is as yet little biological experience. Mounting evidence indicates that conventional linear energy transfer (LET) defined protection quantities (quality factors) may not be appropriate for GCR ions. The available biological data indicates that aluminum alloy structures may generate inherently unhealthy internal spacecraft environments in the thickness range for space applications. Methods for optimization of spacecraft shielding and the associated role of materials selection are discussed. One material which may prove to be an important radiation protection material is hydrogenated carbon nanofibers. c 2001. Elsevier Science Ltd. All rights reserved.

short duration

Development of a Neutron Spectrometer to Assess Biological Radiation Damage Behind Spacecraft Materials

Astronauts who spend months and years traveling long distances in spacecraft and working on other planets will be subjected to high energy radiation of galactic and solar origin without the protection of the Earth's thick (one writer has called it buff) atmosphere and magnetic field. The lack of natural protection will allow high energy cosmic ray particles and solar protons to crash directly into relatively thin spacecraft walls and planetary atmospheres producing energetic secondary particles in these collisions. A substantial fraction of these secondaries will be neutrons that carry no electric charge and, consequently, are difficult to detect. At sea level on Earth the remaining neutrons are the result of many generations (approximately 10) of collisions, have very low energies (scientists call them thermal neutrons), and do not penetrate deeply into the human body. They do contribute to the natural background radiation seen by humans on Earth, but much of the dose is only at the surface or skin of the body. In the International Space Station or on the surface of Mars, the secondary neutrons will be the result of only one or two generations of interaction due to the thinner (about a factor of 20 compared to the Earth's atmosphere) walls or atmosphere, have considerably more energy and penetrate deeply into the human body. In addition, neutrons are substantially moderated by hydrogenous material such as water. A significant fraction of the water exists in the astronaut's body. Therefore, the neutron can not only penetrate more deeply into the body, but also be stopped there and deposit all or most of its radiation dose in organs such as the liver, spleen, kidney, etc. We hypothesize that the risk of serious cancers will be increased for the exposed humans. The portable, real time neutron spectrometer being developed by our team will monitor the environment inside spacecraft structures and on planetary surfaces. Activities supported by this grant will evaluate the neutron environment inside several candidate spacecraft materials at accelerator facilities. These experiments will enable engineers to choose the structure materials that minimize the production of secondary neutrons. With the information that the neutron energy spectrometer produces, scientists and doctors will be able to assess the increased risk of cancer and develop countermeasures. The instrument itself will include an alarm system to warn astronauts when high radiation fluxes are occurring so that they can seek shelter immediately.

Maurer, R. H.

Measurement of Charged Particle Interactions in Spacecraft and Planetary Habitat Shielding Materials

The Microgravity Materials Program, through its 98-HEDS-04 Research Announcement, has called for research to support 'enhanced human radiation protection through the development of light weight soft goods with high radiation protection characteristics.' Given the nature of the particle flux from the Galactic Cosmic Radiation (GCR), and the many constraints on the depth and type of shielding in spacecraft and planetary habitats, it is clear that the health risks these particles present to astronauts in deep space cannot be entirely eliminated. It is the objective of this project to develop a highly accurate model of GCR transport so that NASA can develop and validate the properties of protective shielding materials with the best available information. The validity of the GCR transport model depends in large part on having accurate and precise input data in the form of the charge-changing and fragment production cross sections for the heavy ions of greatest biological significance. The accuracy of the transport model can be evaluated and enhanced by employing the following a three-step strategy: (1) New cross section data will be made available to the NASA-Langley scientists responsible for the transport codes, and will be used as inputs to the codes; (2) The codes will be used to predict additional cross sections and/or details of the radiation field behind realistic shielding arrangements, where the materials and configurations may be quite complex. Mock-ups of the shielding configurations suitable for use in accelerator experiments will obtained by the NASA-Langley co-investigators; and (3) The transport model predictions will be tested in accelerator-based experiments. The time scale for one pass through these steps is well-suited to a four-year schedule. Over a longer term, these steps may be repeated, leading to still further refinements of the transport code, new predictions, and an additional round of measurements, until the desired predictive accuracy is achieved. The focus of this work is primarily on the first of these steps, the determination of fragmentation cross sections, which will be the main task in years one and two. The detailed strategy for carrying out the remainder of the program is more difficult to specify, as it depends on unpredictable factors such as the extent to which the transport model must be modified, schedules for accelerator time, target fabrication, etc.

Zeitlin, C.

Shuttle Spacesuit: Fabric/LCVG Model Validation

A detailed spacesuit computational model is being developed at the Langley Research Center for radiation exposure evaluation studies. The details of the construction of the spacesuit are critical to estimation of exposures and assessing the risk to the astronaut on EVA. Past evaluations of spacesuit shielding properties assumed the basic fabric lay-up (Thermal Micrometeroid Garment, fabric restraints, and pressure envelope) and Liquid Cooling and Ventilation Garment (LCVG) could be homogenized as a single layer overestimating the protective properties over 60 percent of the fabric area. The present spacesuit model represents the inhomogeneous distributions of LCVG materials (mainly the water filled cooling tubes). An experimental test is performed using a 34-MeV proton beam and highresolution detectors to compare with model-predicted transmission factors. Some suggestions are made on possible improved construction methods to improve the spacesuit's protection properties.

Wilson, J. W.

Creation and utilization of a World Wide Web based space radiation effects code: SIREST

In order for humans and electronics to fully and safely operate in the space environment, codes like HZETRN (High Charge and Energy Transport) must be included in any designer's toolbox for design evaluation with respect to radiation damage. Currently, spacecraft designers do not have easy access to accurate radiation codes like HZETRN to evaluate their design for radiation effects on humans and electronics. Today, the World Wide Web is sophisticated enough to support the entire HZETRN code and all of the associated pre and post processing tools. This package is called SIREST (Space Ionizing Radiation Effects and Shielding Tools). There are many advantages to SIREST. The most important advantage is the instant update capability of the web. Another major advantage is the modularity that the web imposes on the code. Right now, the major disadvantage of SIREST will be its modularity inside the designer's system. This mostly comes from the fact that a consistent interface between the designer and the computer system to evaluate the design is incomplete. This, however, is to be solved in the Intelligent Synthesis Environment (ISE) program currently being funded by NASA.

NASA Discipline Radiation Health

Shielded Heavy-Ion Environment Linear Detector (SHIELD): an experiment for the Radiation and Technology Demonstration (RTD) Mission

Radiological assessment of the many cosmic ion species of widely distributed energies requires the use of theoretical transport models to accurately describe diverse physical processes related to nuclear reactions in spacecraft structures, planetary atmospheres and surfaces, and tissues. Heavy-ion transport models that were designed to characterize shielded radiation fields have been validated through comparison with data from thick-target irradiation experiments at particle accelerators. With the RTD Mission comes a unique opportunity to validate existing radiation transport models and guide the development of tools for shield design. For the first time, transport properties will be measured in free-space to characterize the shielding effectiveness of materials that are likely to be aboard interplanetary space missions. Target materials composed of aluminum, advanced composite spacecraft structure and other shielding materials, helium (a propellant) and tissue equivalent matrices will be evaluated. Large solid state detectors will provide kinetic energy and charge identification for incident heavy-ions and for secondary ions created in the target material. Transport calculations using the HZETRN model suggest that 8 g cm -2 thick targets would be adequate to evaluate the shielding effectiveness during solar minimum activity conditions for a period of 30 days or more.

NASA Center LaRC

A Radiation Shielding Code for Spacecraft and Its Validation

The HZETRN code, which uses a deterministic approach pioneered at NASA Langley Research Center, has been developed over the past decade to evaluate the local radiation fields within sensitive materials (electronic devices and human tissue) on spacecraft in the space environment. The code describes the interactions of shield materials with the incident galactic cosmic rays, trapped protons, or energetic protons from solar particle events in free space and low Earth orbit. The content of incident radiations is modified by atomic and nuclear reactions with the spacecraft and radiation shield materials. High-energy heavy ions are fragmented into less massive reaction products, and reaction products are produced by direct knockout of shield constituents or from de-excitation products. An overview of the computational procedures and database which describe these interactions is given. Validation of the code with recent Monte Carlo benchmarks, and laboratory and flight measurement is also included.

Shinn, J. L.

Neutron yields from 155 MeV/nucleon carbon and helium stopping in aluminum

Neutron fluences have been measured from 155 MeV/nucleon 4He and 12C ions stopping in an Al target at laboratory angles between 10 and 160 deg. The resultant spectra were integrated over angle and energy above 10 MeV to produce total neutron yields. Comparison of the two systems shows that approximately two times as many neutrons are produced from 155 MeV/nucleon 4He stopping in Al and 155 MeV/nucleon 12C stopping in Al. Using an energy-dependent geometric cross-section formula to calculate the expected number of primary nuclear interactions shows that the 12C + Al system has, within uncertainties, the same number of neutrons per interaction (0.99 +/- 0.03) as does the 4He + Al system (1.02 +/- 0.04), despite the fact that 12C has three times as many neutrons as does 4He. Energy and angular distributions for both systems are also reported. No major differences can be seen between the two systems in those distributions, except for the overall magnitude. Where possible, the 4He + Al spectra are compared with previously measured spectra from 160 and 177.5 MeV/nucleon 4He interactions in a variety of stopping targets. The reported spectra are consistent with previously measured spectra. The data were acquired to provide data applicable to problems dealing with the determination of the radiation risk to humans engaged in long-term missions in space; however, the data are also of interest for issues related to the determination of the radiation environment in high-altitude flight, with shielding at high-energy heavy-ion accelerators and with doses delivered outside tumor sites treated with high-energy hadronic beams.

NASA Discipline Radiation Health

Accelerator-Based Studies of Heavy Ion Interactions Relevant to Space Biomedicine

Evaluation of the effects of space radiation on the crews of long duration space missions must take into account the interactions of high energy atomic nuclei in spacecraft and planetary habitat shielding and in the bodies of the astronauts. These heavy ions (i.e. heavier than hydrogen), while relatively small in number compared to the total galactic cosmic ray (GCR) charged particle flux, can produce disproportionately large effects by virtue of their high local energy deposition: a single traversal by a heavy charged particle can kill or, what may be worse, severely damage a cell. Research into the pertinent physics and biology of heavy ion interactions has consequently been assigned a high priority in a recent report by a task group of the National Research Council. Fragmentation of the incident heavy ions in shielding or in the human body will modify an initially well known radiation field and thereby complicate both spacecraft shielding design and the evaluation of potential radiation hazards. Since it is impractical to empirically test the radiation transport properties of each possible shielding material and configuration, a great deal of effort is going into the development of models of charged particle fragmentation and transport. Accurate nuclear fragmentation cross sections (probabilities), either in the form of measurements with thin targets or theoretical calculations, are needed for input to the transport models, and fluence measurements (numbers of fragments produced by interactions in thick targets) are needed both to validate the models and to test specific shielding materials and designs. Fluence data are also needed to characterize the incident radiation field in accelerator radiobiology experiments. For a number of years, nuclear fragmentation measurements at GCR-like energies have been carried out at heavy ion accelerators including the LBL Bevalac, Saturne (France), the Synchrophasotron and Nuklotron (Dubna, Russia), SIS-18 (GSI, Germany), the Alternating Gradient Synchrotron at Brookhaven National Laboratory (BNL AGS) and the Heavy Ion Medical Accelerator (HIMAC) in Chiba, Japan. Until fairly recently most of these experiments were done to investigate fundamental problems in nuclear physics, but with the increasing interest in heavy charged particles on the part of the space flight, radiobiology and radiotherapy communities, an increasing number of experiments are being directed at these areas. Some of these measurements are discussed in references therein. Over the past several years, our group has taken cross section and fluence data at the AGS and HIMAC for several incident beams with nuclear charge, Z, between 6 and 26 at energies between 290 and 1050 MeV/nucleon. Iron (Z = 26) has been studied most extensively, since it is the heaviest ion present in significant numbers in the GCR. Targets have included tissue-equivalent and proposed shielding materials, as well as a variety of elemental targets for cross section measurements. Most of the data were taken along the beam axis, but measurements have been made off-axis, as well. Here we present selected data and briefly discuss some implications for spacecraft and planetary habitat design.

Miller, J.

Detailed characterization of the 1087 MeV/nucleon iron-56 beam used for radiobiology at the alternating gradient synchrotron

We report beam characterization and dosimetric measurements made using a 56Fe beam extracted from the Brookhaven National Laboratory Alternating Gradient Synchrotron (AGS) with a kinetic energy of 1087 MeV/nucleon. The measurements reveal that the depth-dose distribution of this beam differs significantly from that obtained with a 600 MeV/nucleon iron beam used in several earlier radiobiology experiments at the Lawrence Berkeley National Laboratory's BEVALAC. We present detailed measurements of beam parameters relevant for radiobiology, including track- and dose-averaged linear energy transfer (LET), fragment composition and LET spectra measured behind sample holders used in irradiations of biological samples. We also report measurements of fluence behind three depths (1.94, 4.68 and 9.35 g cm(-2)) of polyethylene targets with the 1087 MeV/nucleon beam, and behind 1.94 g cm(-2) of polyethylene with a 610 MeV/nucleon beam delivered by the AGS. These results are compared to earlier measurements with the 600 MeV/nucleon beam at the BEVALAC.

NASA Discipline Radiation Health

Wall effects observed in tissue-equivalent proportional counters from 1.05 GeV/nucleon iron-56 particles

Tissue-equivalent proportional counters (TEPCs) have been used to measure energy deposition in simulated volumes of tissue ranging in diameter from 0.1 to 10 microm. There has been some concern that the wall used to define the volume of interest could influence energy deposition within the sensitive volume because it has a density significantly greater than that of the cavity gas. These effects become important for high-velocity heavy ions. Measurements of energy deposition were made for 1 GeV/nucleon iron particles in a TEPC simulating a 1-microm-diameter sphere of tissue. The TEPC was nested within a particle spectrometer that provided identification and flight path of individual particles. Energy deposition was studied as a function of pathlength through the TEPC. Approximately 30% of the energy transfer along trajectories through the center of the detector escapes the sensitive volume. The response of the TEPC, for trajectories through the detector, is always larger than calculations for energy loss in a homogeneous medium. This enhancement is greatest for trajectories near the cavity/wall interface. An integration of the response indicates that charged-particle equilibrium is essentially achieved for a wall thickness of 2.54 mm. However, estimates of the linear energy transfer for the incident particles are influenced by these wall effects.

Non-NASA Center

Ground-based simulations of cosmic ray heavy ion interactions in spacecraft and planetary habitat shielding materials

This paper surveys some recent accelerator-based measurements of the nuclear fragmentation of high energy nuclei in shielding and tissue-equivalent materials. These data are needed to make accurate predictions of the radiation field produced at depth in spacecraft and planetary habitat shielding materials and in the human body by heavy charged particles in the galactic cosmic radiation. Projectile-target combinations include 1 GeV/nucleon 56Fe incident on aluminum and graphite and 600 MeV/nucleon 56Fe and 290 MeV/nucleon 12C on polyethylene. We present examples of the dependence of fragmentation on material type and thickness, of a comparison between data and a fragmentation model, and of multiple fragments produced along the beam axis.

NASA Discipline Radiation Health

Analysis of the pre-flight and post-flight calibration procedures performed on the Liulin space radiation dosimeter

Liulin, a dosimetry-radiometry system, was developed to satisfy the requirements for active flux and dose rate measurements for the flight of the second Bulgarian cosmonaut in 1988. The system consists of a compact battery-operated silicon solid state detector unit and a read/write microcomputer and telemetry unit. We describe the pre-flight calibrations with charged particles, using radioactive sources and accelerated 170 MeV/nucleon proton and alpha particles at the Dubna, Russia cyclotron. We discuss comparisons with data obtained on Mir with the French-built tissue equivalent LET spectrometer NAUSICAA. Lastly, we describe post-flight calibrations performed with 1 GeV/nucleon 56Fe ions at the Brookhaven National Laboratory AGS accelerator, where the instrument was mounted in tandem with several thin position-sensitive silicon detectors behind a stopping target. The silicon detectors provided an energy spectrum for the surviving charged nuclear fragments for which the flux and absorbed dose were recorded by Liulin.

long duration

Production of neutrons from interactions of GCR-like particles

In order to help assess the risk to astronauts due to the long-term exposure to the natural radiation environment in space, an understanding of how the primary radiation field is changed when passing through shielding and tissue materials must be obtained. One important aspect of the change in the primary radiation field after passing through shielding materials is the production of secondary particles from the breakup of the primary. Neutrons are an important component of the secondary particle field due to their relatively high biological weighting factors, and due to their relative abundance, especially behind thick shielding scenarios. Because of the complexity of the problem, the estimation of the risk from exposure to the secondary neutron field must be handled using calculational techniques. However, those calculations will need an extensive set of neutron cross section and thicktarget neutron yield data in order to make an accurate assessment of the risk. In this paper we briefly survey the existing neutron-production data sets that are applicable to the space radiation transport problem, and we point out how neutron production from protons is different than neutron production from heavy ions. We also make comparisons of one the heavy-ion data sets with Boltzmann-Uehling-Uhlenbeck (BUU) calculations.

Non-NASA Center

Heavy fragment production cross sections from 1.05 GeV/nucleon 56Fe in C, Al, Cu, Pb, and CH2 targets

We have obtained charge-changing cross sections and partial cross sections for fragmentation of 1.05 GeV/nucleon Fe projectiles incident on H, C, Al, Cu, and Pb nuclei. The energy region covered by this experiment is critical for an understanding of galactic cosmic ray propagation and space radiation biophysics. Surviving primary beam particles and fragments with charges from 12 to 25 produced within a forward cone of half-angle 61 mrad were detected using a silicon detector telescope to identify their charge and the cross sections were calculated after correction of the measured yields for finite target thickness effects. The cross sections are compared to model calculations and to previous measurements. Cross sections for the production of fragments with even-numbered nuclear charges are seen to be enhanced in almost all cases.

NASA Center HQS

The fragmentation of 510 MeV/nucleon iron-56 in polyethylene. II. Comparisons between data and a model

The results of a Monte Carlo model for calculating fragment fluences and LET spectra are compared to data taken with 600 MeV/nucleon iron ions incident on an accelerator beamline configured for irradiation of biological samples, with no target and with 2, 5 and 8 cm of polyethylene. The model uses a multi-generation nuclear fragmentation code, coupled with a formulation of ionization energy loss based on the Bethe-Bloch equation. In the region where the data are reliable and the experimental acceptance is well understood, many of the features of the experimental spectra are well replicated by the model. To obtain good agreement with the experimental data, the model must allow for at least two generations of fragment production in the target.

NASA Discipline Number 99-99