Quantum Vulnerability Analysis to Guide Robust Quantum Computing System Design
Not Available
Engineering topics
Publications and source records attributed to Yuan, Xu.
Not Available
Space charge effect (SCE) along the beam line will decrease beam quality. Space charge compensation (SCC) with extra gas injection is a high-efficiency method to reduce SCE. In this paper, we will report the experimental results on the beam profile, potential distribution, beam emittance, and beam transmission efficiency of a 35 keV/90 mA H{sup +} beam and a 40 keV/10 mA He{sup +} beam compensated by Ar/Kr. The influence of gas type, gas flow, and injection location will be discussed. Emphasis is laid on the consideration of SCC when designing and commissioning a high intensity ion beam injector. Based on measured data, a new definition of space charge compensation degree is proposed.
A grazing-incidence flat-field extreme ultraviolet (EUV) spectrometer has been newly developed in HL-2A tokamak. Typical spectral lines are observed from intrinsic impurities of carbon, oxygen, iron, and extrinsic impurity of helium in the wavelength range of 20 A-500 A. Bremsstrahlung continuum is measured at different electron densities of HL-2A discharges to calibrate absolute sensitivity of the EUV spectrometer system and to measure effective ionic charge, Z{sub eff}. The sensitivity of a vacuum ultraviolet (VUV) spectrometer system is also absolutely calibrated in overlapped wavelength range of 300 A-500 A by comparing the intensity between VUV and EUV line emissions.
A 1 m normal incidence vacuum ultraviolet (VUV) spectrometer has been developed for spatial distribution measurement of edge impurity line emission in the wavelength range of 300-3200 A on HL-2A tokamak. A vertical profile of the impurity line emission is measured with a space-resolved slit placed between an entrance slit and a grating of the spectrometer. Two concave 1200 grooves/mm gratings blazed at 800 and 1500 A are set on a rotatable holder in the spectrometer, which gives wavelength dispersion of 0.12 mm/A. A back-illuminated charge-coupled device is used as a detector with an image size of 6.7x26.6 mm{sup 2} (26x26 {mu}m{sup 2}/pixel). An excellent spatial resolution of 2 mm is obtained with good spectral resolution of 0.15 A when the space-resolved slit of 50 {mu}m in width is used. The space-resolved spectra thus provide three radial profiles of emission line intensity, ion temperature, and poloidal rotation. The electron temperature can be measured by the intensity ratio, e.g., CIII 2s{sup 2}-2s3p (386 A)/2s{sup 2}-2s2p (977 A). The sensitivity of the spectrometer is calibrated in situ by using the VUV bremsstrahlung continuum radiation emitted from the tokamak plasma. A good performance of the spectrometer system for the edge impurity and temperature profile measurements is presented with results on Ohmic and H-mode discharges.