Crane-Load Contact Sensor

An electronic instrument has been developed as a prototype of a portable crane-load contact sensor. Such a sensor could be helpful in an application in which the load rests on a base in a horizontal position determined by vertical alignment pins (see Figure 1). If the crane is not positioned to lift the load precisely vertically, then the load can be expected to swing once it has been lifted clear of the pins. If the load is especially heavy, large, and/or fragile, it could hurt workers and/or damage itself and nearby objects. By indicating whether the load remains in contact with the pins when it has been lifted a fraction of the length of the pins, the crane-load contact sensor helps the crane operator determine whether it is safe to lift the load clear of the pins: If there is contact, then the load is resting against the sides of the pins and, hence, it may not be safe to lift; if contact is occasionally broken, then the load is probably not resting against the pins, so it should be safe to lift. It is assumed that the load and base, or at least the pins and the surfaces of the alignment holes in the load, are electrically conductive, so the instrument can use electrical contact to indicate mechanical contact. However, DC resistance cannot be used as an indicator of contact for the following reasons: The load and the base are both electrically grounded through cables (the load is grounded through the lifting cable of the crane) to prevent discharge of static electricity. In other words, the DC resistance between the load and the pins is always low, as though they were always in direct contact. Therefore, instead of DC resistance, the instrument utilizes the AC electrical impedance between the pins and the load. The signal frequency used in the measurement is high enough (.1 MHz) that the impedance contributed by the cables and the electrical ground network of the building in which the crane and the base are situated is significantly greater than the contact impedance between the pins and the load. The instrument includes a signal generator and voltage-measuring circuitry, and is connected to the load and the base as shown in Figure 2. The output of the signal generator (typically having amplitude of the order of a volt) is applied to the load via a 50-resistor, and the voltage between the load and the pins is measured. When the load and the pins are not in contact, the impedance between them is relatively high, causing the measured voltage to exceed a threshold value. When the load and the pins are in contact, the impedance between them falls to a much lower value, causing the voltage to fall below the threshold value. The voltage-measuring circuitry turns on a red light-emitting diode (LED) to indicate the lower-voltage/ contact condition. Whenever the contact has been broken and the non-contact/higher-voltage condition has lasted for more than 2 ms, the voltage-measuring circuitry indicates this condition by blinking a green LED.

Youngquist, Robert

Magnetocaloric Pumping of Liquid Oxygen

The field-induced force density on a magnetic fluid is proportional to the magnetic susceptibility times the gradient of the magnetic field squared. The direction of the force is towards increasing magnetic field (positive gradient). Applying a magnetic field to a magnetic fluid will result in a force from all directions towards the location of peak field. Since the magnetic field is conservative and there are no magnetic monopoles, the net field-induced force on any fluid of constant susceptibly will be zero. The only manner to obtain a nonzero net field-induced force is to vary the susceptibility of the fluid. At the gas/liquid interface of liquid oxygen, the susceptibility varies drastically, and the exploitation of the resultant large net forces. An alternative method of varying the magnetic susceptibility is to vary the temperature of the fluid. The magnetic susceptibility of paramagnetic liquid oxygen obeys the Curie-Weiss law: it is inversely proportional to temperature. By applying a temperature gradient in the presence of a symmetric magnetic field, a nonzero net force results. Much of the theory of the so-called Magnetocaloric Effect has previously been developed for and applied to ferromagnetic fluids, or ferrofluids, but is readily applied to paramagnetic liquid oxygen.

Immer, Christopher

Pumping Liquid Oxygen by Use of Pulsed Magnetic Fields

An effort is underway to develop a method of pumping small amounts of liquid oxygen by use of pulsed magnetic fields. This development is motivated by a desire to reduce corrosion and hazards of explosion and combustion by eliminating all moving pump parts in contact with the pumped oxygen. The method exploits the known paramagnetism of liquid oxygen. Since they both behave similarly, the existing theory of ferrofluids (liquids with colloidally suspended magnetic particles) is directly applicable to paramagnetic liquid oxygen. In general, the force density of the paramagnetic interaction is proportional to the magnetic susceptibility multiplied by the gradient of the square of the magnitude of the magnetic field. The local force is in the direction of intensifying magnetic field. In the case of liquid oxygen, the magnetic susceptibility is large enough that a strong magnetic-field gradient can lift the liquid in normal Earth gravitation.

Youngquist, Robert

Capacitive Sensors for Measuring Masses of Cryogenic Fluids

An effort is under way to develop capacitive sensors for measuring the masses of cryogenic fluids in tanks. These sensors are intended to function in both microgravitational and normal gravitational settings, and should not be confused with level sensors, including capacitive ones. A sensor of this type is conceptually simple in the sense that (1) it includes only one capacitor and (2) if properly designed, its single capacitance reading should be readily convertible to a close approximation of the mass of the cryogenic fluid in the tank. Consider a pair of electrically insulated electrodes used as a simple capacitive sensor. In general, the capacitance is proportional to the permittivity of the dielectric medium (in this case, a cryogenic fluid) between the electrodes. The success of design and operation of a sensor of the present type depends on the accuracy of the assumption that to a close approximation, the permittivity of the cryogenic fluid varies linearly with the density of the fluid. Data on liquid nitrogen, liquid oxygen, and liquid hydrogen, reported by the National Institute of Standards and Technology, indicate that the permittivities and densities of these fluids are, indeed, linearly related to within a few tenths of a percent over the pressure and temperature regions of interest. Hence, ignoring geometric effects for the moment, the capacitance between two electrodes immersed in the fluid should vary linearly with the density, and, hence, with the mass of the fluid. Of course, it is necessary to take account of the tank geometry. Because most cryogenic tanks do not have uniform cross sections, the readings of level sensors, including capacitive ones, are not linearly correlated with the masses of fluids in the tanks. In a sensor of the present type, the capacitor electrodes are shaped so that at a given height, the capacitance per unit height is approximately proportional to the cross-sectional area of the tank in the horizontal plane at that height (see figure).

Nurge, Mark

Optoelectronic Tool Adds Scale Marks to Photographic Images

A simple, easy-to-use optoelectronic tool projects scale marks that become incorporated into photographic images (including film and electronic images). The sizes of objects depicted in the images can readily be measured by reference to the scale marks. The role played by the scale marks projected by this tool is the same as that of the scale marks on a ruler placed in a scene for the purpose of establishing a length scale. However, this tool offers the advantage that it can put scale marks quickly and safely in any visible location, including a location in which placement of a ruler would be difficult, unsafe, or time-consuming. The tool (see Figure 1) includes an aluminum housing, within which are mounted four laser diodes that operate at a wavelength of 670 nm. The laser diodes are spaced 1 in. (2.54 cm) apart along a baseline. The laser diodes are mounted with setscrews, which are used to adjust their beams to make them all parallel to each other and perpendicular to the baseline. During the adjustment process, the effect of the adjustments is observed by measuring the positions of the laser-beam spots on a target 80 ft (approx.24 m) away. Once the adjustments have been completed, the laser beams define three 1-in. (2.54-cm) intervals and the location of each beam is defined to within 1/16 in. (approx.1.6 mm) at any target distance out to about 80 ft (approx.24 m). The distance between the laser-beam spots as seen in an image is strictly defined only along an axis parallel to the baseline and perpendicular to the laser beam (also perpendicular to the line of sight of the camera, assuming that the camera-to-target distance is much greater than the distance between the tool and the camera lens). If a flat target surface illuminated by the laser beams is tilted with respect to the aforesaid axis, then the distance along the target surface between scale marks is proportional to the secant of the tilt angle. If one knows the tilt angle, one can correct for it. Even if one does not know the tilt angle precisely, it may not matter: For example, at a tilt of 10 , the secant is approximately 1.0154, so that the tilt error is only about 1.54 percent, which is negligibly small for a typical application in which only approximate measurements are needed.

Stevenson, Charlie

Dynamics of a Finite Liquid Oxygen (LOX) Column in a Pulsed Magnetic Field

It is well known that liquid oxygen has a sufficient paramagnetic susceptibility that a strong magnetic field gradient can lift it in the earth's gravitational field. The movement of liquid oxygen is vital to the space program since it one of the primary oxidizers used for propulsion. Transport of liquid oxygen (LOX) via direct interaction of the magnetic fields (B field) with the fluid is a current topic of research and development at Kennedy Space Center, FL. This method of transporting (i.e. pumping) LOX may have particular advantages on Mars and other reduced gravitational environments, namely safety and reliability. This paper will address transport of a magnetic fluid, LOX, via phased-pulsed electromagnets acting on the edge of the column of fluid. The authors have developed a physical model from first-principles for the motion of a magnetic fluid in a particular U-tube geometry subjected to a pulsed magnetic field from an arbitrary solenoidal electromagnet. Experimental data that have been collected from the analogous geometry correlate well to that of the ab-initio calculations.

Youngquist, Robert

Optoelectronic Alignment And Ultrasonic Ranging Apparatus

Beam of light guides alignment, then range measured by use of ultrasound. Optoelectronic/ultrasonic apparatus facilitates three-dimensional alignment of spot on one object with respect to facing (but not touching) spot on another nearby object. Designed to help in positioning external tank of space shuttle between two solid rocket boosters. Useful in other applications to align large components to be locked together in assemblies.

Collins, J. David