Yashchuk, Valeriy V.

Publications and source records attributed to Yashchuk, Valeriy V..

At least 19 records

Binary pseudo-random array standards for calibration of 3D optical surface profilers used for metrology with significantly curved x-ray optics

High-accuracy metrology is vitally important in manufacturing ultra-high-quality free-form mirrors designed to manipulate X-ray light with nanometer-scale wavelengths. The current capabilities and possibility for improvements in X-ray mirror manufacturing are limited by inherent imperfections of the integrated metrology tools. In the case of Fizeau interferometry, metrology tools are currently calibrated with super-polished flat test-standard/reference mirrors. This is acceptable for measuring slightly curved X-ray optics. However, for even moderately curved aspherical X-ray mirrors the flat-reference calibration is not sufficiently accurate and stitching Fizeau interferometer-based surface metrology is used to mitigate the problem. But still, the retrace and aberration errors, as well as the limited spatial resolution, described with the instrument transfer function (ITF), can be transferred into the optical surface topography of X-ray mirrors obtained in stitching metrology. For ITF calibration, we have developed an original technique, based on test standards structured as two-dimensional (2D) highly-randomized (HR) binary pseudo-random arrays (BPRAs). The technique employs the unique properties of the HR BPRA patterns in the spatial frequency domain., i.e. the inherent 2D power spectral density of the HR BPRA pattern has a deterministic white-noise-like character that allows direct determination of the ITF with uniform sensitivity over the entire spatial frequency range and field-of-view of an instrument. Here, we explore technological, metrological, and analytical aspects essential for calibration of the retrace and aberration errors of Fizeau interferometers using different types of tilted test samples, including a super-polished reference mirror for the re-trace calibration and the uniformly redundant array (URA) BPRA standards for the geometrical distortion (aberration) calibration. While the first method was previously demonstrated by researchers at DIAMOND Light Source, a method based on the URA BPRA is described and demonstrated here for the first time. We outline the design and fabrication process used in fabrication of URA BPRA test standards, and present the results of application of the URA BPRA standards demonstrating the high efficacy of our approach to geometrical distortion calibration of Fizeau interferometers. We also discuss the possible sources of unexpected peculiarities of the systematic errors, including an astigmatic character of the retrace error, observed with Fizeau interferometers at the Advanced Light Source X-Ray Optics Laboratory.

Munechika, Keiko↗

Towards a new generation long trace profiler LTP-2020: optical design of pencil beam interferometry sensor

Improvements in the quality of synchrotron beamline x-ray optics required for next-generation light sources (e.g. the ALS Upgrade project) drive the need to improve the performance of the metrology instrumentation used to measure these components. The Long Trace Profiler (LTP) that is in use at many synchrotron metrology laboratories around the world has some known issues that affect the accuracy of its measurements. The main error source is optical path difference (OPD) phase error introduced into the probe beam by inhomogeneities in the glass components used in the optical head. We have developed a new optical head design, LTP-2020, that replaces the cube polarizing beamsplitter (PBS) with a thin wedge plate polarizing beamsplitter (WPBS) and replaces the cemented doublet lens with an aspheric singlet. Both of these components significantly reduce the glass volume traversed by the laser probe beam. Careful attention to ghost ray interference produced by back reflection from optical surfaces is necessary to minimize distortion in the primary image that translates into systematic error in the slope angle measurement. We make extensive use of a commercial raytracing program to model the back reflections and adjust component parameters as necessary to minimize distortion. Deliberate misalignment of components is necessary to make the system perform correctly. Stringent requirements are placed on the 45◦ incidence coatings on the WPBS and on the normal incidence coatings on the lens and camera window elements. We encourage our colleagues who wish to upgrade their current LTP systems to join us in the procurement of these custom optical components.

Takacs, Peter Z.↗

Simulations of applications using diaboloid mirrors

The diaboloid is a reflecting surface that converts a spherical wave to a cylindrical wave. This complex surface may find application in new Advanced Light Source bending-magnet beamlines or in other beamlines that now use toroidal optics for astigmatic focusing. Here, the numerical implementation of diaboloid mirrors is described, and the benefit of this mirror in beamlines exploiting diffraction-limited storage rings is studied by ray tracing. The use of diaboloids becomes especially interesting for the new low-emittance storage rings because the reduction of aberration becomes essential for such small sources. Here, the validity of the toroidal and other mirror surfaces approximating the diaboloid, and the effect of the mirror magnification, are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Diaboloidal mirrors: algebraic solution and surface shape approximations

A new type of optical element that can focus a cylindrical wave to a point focus (or vice versa) is analytically described. Such waves are, for example, produced in a beamline where light is collimated in one direction and then doubly focused by a single optic. A classical example in X-ray optics is the collimated two-crystal monochromator, with toroidal mirror refocusing. The element here replaces the toroid, and in such a system provides completely aberration free, point-to-point imaging of rays from the on-axis source point. We present an analytic solution for the mirror shape in its laboratory coordinate system with zero slope at the centre, and approximate solutions, based on bending an oblique circular cone and a bent right circular cylinder, that may facilitate fabrication and metrology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Binary pseudorandom array test standard optimized for characterization of large field-of-view optical interferometers

Recently, a technique for calibrating the modulation transfer function (MTF) of a broad variety of metrology instrumentation has been demonstrated. This technique is based on test samples structured as one-dimensional binary pseudo-random (BPR) sequences and two-dimensional BPR arrays (BPRAs). The inherent power spectral density of BPR gratings (sequences) and arrays has a deterministic white-noise-like character that allows direct determination of the MTF with uniform sensitivity over the entire spatial frequency range and field-of-view of an instrument. As such, the BPR samples satisfy the characteristics of a test standard: functionality, ease of specification and fabrication, reproducibility, and low sensitivity to manufacturing error. Here we discuss our recent developments directed to the optimization of the sample design, fabrication, application, and data processing procedures, suitable for thorough characterization of large aperture optical interferometers. Compared with the previous coded-aperture based design, the improved, 'highly randomized' BPRA pattern of the new test standard provides better accuracy and reliability of instrument MTF and aberration characterization, and enables operation optimization of large aperture optical interferometers. We describe the pattern generation algorithm and tests to verify the compliance to desired BPRA topography. The data acquisition and analysis procedures for different applications of the technique are also discussed.

Yashchuk, Valeriy V.↗

Analytical expressions of the surface shape of ‘diaboloid’ mirrors

Modern deterministic polishing processes allow fabrication of x-ray optics with almost any arbitrary aspherical surface shape. Among these optics, the so called "diaboloid"mirror is of special interest. The diaboloid mirror that converts a cylindrical wave to a spherical wave would improve focusing in x-ray beamlines implementing a diffraction element between a parabolic cylinder and a toroidal mirror. The replacement of the toroidal mirror in existing beamlines by the diaboloid mirror would mitigate aberrations. The shape of the diaboloid mirror is usually calculated numerically based on a truncated polynomial solution of the optical path problem. Here, we present an exact analytical solution for the shape of a diaboloid mirror as a function of the conjugate parameters of the mirror placed in a beamline. The derived analytical expressions for the diaboloid mirror in both the canonical and mirror-based coordinate systems are implemented in ray-tracing simulations to verify the beamline performances.

Yashchuk, Valeriy V.↗

Characterization of groove density variation of VLS gratings with ALS XROL LTP-II in different operation modes

The long trace profiler, LTP-II, available at the Advanced Light Source (ALS) X-ray Optics Laboratory (XROL), was recently upgraded by replacing a multimode diode laser light source with a single-mode, wavelength-stabilized, fibercoupled diode laser system. The upgrade enables us to reliably characterize the lateral variation of groove density of variable-line-spacing (VLS) x-ray diffraction gratings. Here, we discuss the LTP-II performance with an example of measurements with a VLS grating with the groove density at the grating center of 300 lines/mm. For the measurements, we use the LTP-II in two different operation arrangements, the single Gaussian beam and the pencil beam interferometer arrangements. For each operation arrangement, we apply two data processing algorithms: with calculating the centroid position and with determining the position of a characteristic features of the detected beam intensity distributions. Additionally, we discuss the observed strong correlation between the LTP-II modes of operation and the resulted (extracted) groove density variations. We also speculate on possible origin of the correlation.

42 ENGINEERING↗

Raytracing the long trace profiler

The optical design of the Long Trace Profiler optical system is explored with a commercial raytrace program, Zemax OpticStudio™ (ZOS)1, with the intent of finding and correcting sources of systematic error. ZOS provides both geometric raytracing tools and physical optics Gaussian beam propagation and diffraction image calculation tools, and two design modes, sequential component (SC) and non-sequential component (NSC) that are optimized for different aspects of the design process. The original LTP-II system employs a singlet lens with a 1250 mm focal length. It is optimized to provide minimum distortion over a surface slope angle range of ±5 mrad. Using the ZOS tools, we are able to simulate ghost rays that produce distortion in the beam spot image and can minimize the distortion by deliberate misalignment of the beamsplitter (BS) components. Unfortunately, the reference beam is compromised because of the component tilts. The most recent LTP500 system design simplifies the optical system and makes the reference beam usable again, even with misalignment of the polarizing beamsplitter (PBS). Two lenses are designed for the LTP500 - a cemented doublet that has been fabricated, and a singlet with one aspheric surface. Both have focal distances of 500 mm with an expanded angular measurement range of ±10 mrad. The aspheric singlet provides superior performance. ZOS allows the import of wavefront measurement data produced by commercial interferometer software. We apply the wavefront error measurement from the cemented doublet to the model to show that the 19nm RMS wavefront error needs to be improved by at least a factor of ten in order to reduce the systematic error to a level that will allow the LTP to approach its design limit of a few tens of nanoradians.

Takacs, Peter Z.↗

Multifunctional light beam source for surface slope measuring long trace profilers

To fully exploit the advantages of fourth-generation synchrotron light sources, diffraction-limited-storage-rings (DLSR) and fully coherent free electron lasers (FELs), beamline mirrors and diffraction grating must be of exceptional quality. To achieve the required mirror and grating quality, the metrology instrumentation and methods used to characterize these challenging optics and, even more so, optical assemblies must also offer exceptional functionality and performance. One of the most widely used slope measuring instruments for characterizing x-ray optics is the long trace profiler (LTP). The easily reconfigurable mechanical design of the LTP allows optimization of the profiler arrangement to the specifics of a particular metrology task. Here, we discuss the optical schematic, design, and performance of an original multifunctional light beam source that provides functional flexibility of the LTP optical sensor. With this source, the LTP can be easily reconfigured for measurements of x-ray mirrors or diffraction gratings that have widely different source coherence requirements. Usage of a source with a low degree of coherence for mirror metrology helps to suppress the LTP systematic errors due to spurious interference effects in the LTP optical elements. A high-coherence narrow-band source is used for groove-density-distribution characterization of x-ray diffraction gratings. The systematic error and spatial resolution of the LTP with the different sources is also measured and analyzed.

Yashchuk, Valeriy V.↗

Super-resolution surface slope metrology of x-ray mirrors

We present experimental, analytical, and numerical methods developed for reconstruction (deconvolution) of one-dimensional (1D) surface slope profiles over the spatial frequency range where the raw data are significantly perturbed due to the limited resolution of the measurement instrument. We characterize the spatial resolution properties of a profiler with the instrument's transfer function (ITF). To precisely measure the ITF, we apply a recently developed method utilizing test surfaces with 1D linear chirped height profiles of constant slope amplitude. Based on the results of the ITF calibration, we determine parameters of an analytical model for the ITF that is used in the original reconstruction software. Here, we treat surface slope metrology data obtained with the Optical Surface Measuring System (OSMS), using as a sensor an electronic autocollimator (AC) ELCOMAT-3000. The spatial resolution of the OSMS is limited by the size of the AC light-beam-collimating aperture. For the purposes of this investigation, the OSMS is equipped with a circular aperture with a diameter of 2.5 mm. This is a typical arrangement of most AC-based slope profilers developed for surface slope metrology of state-of-the-art x-ray mirrors. Using the example of surface slope metrology of two state-of-the-art elliptically shaped x-ray focusing mirrors, we demonstrate that the developed data reconstruction procedure allows us to significantly improve the accuracy of surface slope metrology with the OSMS over the spatial wavelength range from ~1.6 mm to 7 mm. Thus, the amplitude of the quasi-periodic error characteristic of the deterministic polishing process used appears to be higher by a factor of~2 than is apparent from the rough metrology data. Underestimation of the surface slope errors in this spatial wavelength range can lead to serious errors in the expected performance of x-ray mirrors in synchrotron beamlines, especially at modern light sources utilizing coherent x rays, where the perturbations can lead to increased speckle-like intensity variation.

47 OTHER INSTRUMENTATION↗

Transfer of autocollimator calibration for use with scanning gantry profilometers for accurate determination of surface slope and curvature of state-of-the-art x-ray mirrors

X-ray optics, desired for beamlines at free-electron-laser and diffraction-limited-storage-ring x-ray light sources, must have almost perfect surfaces, capable of delivering light to experiments without significant degradation of brightness and coherence. To accurately characterize such optics at an optical metrology lab, two basic types of surface slope profilometers are used: The long trace profilers (LTPs) and nanometer optical measuring (NOM) like angular deflectometers, based on electronic autocollimator (AC) ELCOMAT-3000. The inherent systematic errors of the instrument's optical sensors set the principle limit to their measuring performance. Where autocollimator of a NOM-like profiler may be calibrated at a unique dedicated facility, this is for a particular configuration of distance, aperture size, and angular range that does not always match the exact use in a scanning measurement with the profiler. Here we discuss the developed methodology, experimental set-up, and numerical methods of transferring the calibration of one reference AC to the scanning AC of the Optical Surface Measuring System (OSMS), recently brought to operation at the ALS Xray Optics Laboratory. We show that precision calibration of the OSMS performed in three steps, allows us to provide high confidence and accuracy low-spatial-frequency metrology and not â€print into' measurements the inherent systematic error of tool in use. Here, with the examples of the OSMS measurements with a state-of-The-Art x-ray aspherical mirror, available from one of the most advanced vendors of X-ray optics, we demonstrate the high efficacy of the developed calibration procedure. The results of our work are important for obtaining high reliability data, needed for sophisticated numerical simulations of beamline performance and optimization of beamline usage of the optics. This work was supported by the U. S. Department of Energy under contract number DE-AC02-05CH11231.

47 OTHER INSTRUMENTATION↗

Investigation on lateral resolution of surface slope profilers

Here, we investigate and compare the spatial (lateral) resolution, or more generally, the optical/instrumental transfer function (OTF/ITF) of surface slope measuring profilometers of two different types that are commonly used for high accuracy characterization of x-ray optics at the long-spatial-wavelength range. These are an autocollimator based profiler, Optical Surface Measuring System (OSMS), and a long trace profiler, LTP-II, both available at the Advanced Light Source (ALS) X-Ray Optics Lab (XROL). In the OSMS, an ELCOMAT-3000 electronic auto-collimator, vertically mounted to the translation carriage and equipped with an aperture of 2.5 mm diameter, is scanned along the surface under test. The LTP-II OTF has been measured for two different configurations, a classical two-beam pencil-beam-interferometry and a single-Gaussian-beam deflectometry. For the ITF calibration, we apply a recently developed method based on test surfaces with one-dimensional (1D) linear chirped height profiles of constant slope amplitude. Analytical expressions for the OTFs, empirically deduced based on the experimental results, are presented. We also discuss the application of the results of the ITF measurements and modeling to improve the surface slope metrology with state-of-the-art x-ray mirrors.

42 ENGINEERING↗

Stochastic analysis of surface metrology

The design and evaluation of the expected performance of optical systems require sophisticated and reliable information about the surface topography for planned optical elements before they are fabricated. Modern x-ray source facilities are reliant upon the availability of optics with unprecedented quality (surface slope accuracy <0.1 μrad). The problem is especially complex in the case of x-ray optics, particularly for the X-ray Surveyor under development and other missions. The high angular resolution and throughput of future x-ray space observatories requires hundreds of square meters of high-quality optics. The uniqueness of the optics and limited number of proficient vendors makes the fabrication extremely time consuming and expensive, mostly due to the limitations in accuracy and measurement rate of metrology used in fabrication. Here, we discuss improvements in metrology efficacy via comprehensive statistical analysis of a compact volume of metrology data. The data are considered stochastic, and a statistical model called invertible time-invariant linear filter (InTILF) is developed now for two-dimensional (2-D) surface profiles to provide compact description of the 2-D data in addition to one-dimensional data treated so far. The InTILF model captures stochastic patterns in the data and can be used as a quality metric and feedback to polishing processes, avoiding high-resolution metrology measurements over the entire optical surface. The modeling, implemented in our BeatMark™ software, allows simulating metrology data for optics made by the same vendor and technology. The data are vital for reliable specification for optical fabrication, to be exactly adequate for the required system performance.

42 ENGINEERING↗

Ex situ metrology and data analysis for optimization of beamline performance of aspherical pre-shaped x-ray mirrors at the advanced light source

Super high quality aspherical x-ray mirrors with a residual slope error of ~100 nrad (root-mean-square) and a height error of ~1-2 nm (peak-to-valley), and even lower, are now available from a number of the most advanced vendors utilizing deterministic polishing techniques. The mirror specification for the fabrication is based on the simulations of the desired performance of the mirror in the beamline optical system and is normally given with the acceptable level of deviation of the mirror figure and finish from the desired ideal shape. For example, in the case of aspherical x-ray mirrors designed for the Advanced Light Source (ALS) QERLIN beamline, the ideal shape is defined with the beamline application (conjugate) parameters and their tolerances. Here, we first introduce an original procedure and dedicated software developed at the ALS X-Ray Optics Laboratory (XROL) for optimization of beamline performance of pre-shaped hyperbolic and elliptical mirrors. The optimization is based on results of ex situ surface slope metrology and consists in minimization of the mirror shape error by determining the conjugate parameters of the best-fit ideal shape within the specified tolerances. We describe novel optical metrology instrumentation, measuring techniques, and analytical methods used at the XROL for acquisition of surface slope data and optimization of the optic’s beamline performance. The high efficacy of the developed experimental methods and data analysis procedures is reflected in results of measurements with and performance optimization of hyperbolic and elliptical cylinder mirrors designed and fabricated for the ALS QERLIN beamline.

47 OTHER INSTRUMENTATION↗

Environmental influences on autocollimator-based angle and form metrology

Deflectometric profilometers are indispensable tools for the precision form measurement of beam-shaping optics of synchrotrons and x-ray free electron lasers. They are used in metrology labs for x-ray optics worldwide and are crucial for providing measurement accuracy dictated by the form tolerances for modern state-of-the-art x-ray optics. Deflectometric profilometers use surface slope (angle) to assess form, and they utilize commercial autocollimators for the contactless slope measurement. In this contribution, we discuss the influences of environmental parameters, such as temperature and air pressure, including their gradients, on high-accuracy metrology with autocollimators in profilometers. They can cause substantial systematic errors in form measurement, especially in the case of large and strongly curved optical surfaces of high dynamic range. Relative angle and form measuring errors of the order of 10 -4 are to be expected. We characterize environmental influences by extended theoretical and experimental investigations and derive strategies for correcting them. Additionally, we report on the possibility to minimize the contributions of some errors by the application of sophisticated experimental arrangements and methods. We aim at approaching fundamental limits in autocollimator-based slope and form metrology.

47 OTHER INSTRUMENTATION↗

Optimization of the size and shape of the scanning aperture in autocollimator-based deflectometric profilometers

Deflectometric profilometers based on industrial electronic autocollimators (ACs), as the ELCOMAT-3000, have become indispensable tools for precision form measurements of optical surfaces. A growing number of labs at synchrotron and free electron laser x-ray facilities are going for BESSY-II NOM-like versions of the AC-based profilometers. These tools have proven capable of characterizing state-of-the-art aspherical x-ray optics with an accuracy on the level of 100 nrad (root-mean-square) over the spatial frequency range limited by the size of the aperture used in the profilometer. Normally, a round aperture with a diameter of about 2.5 mm is used. Previous investigations have shown that with the optimally aligned 2.5-mm aperture, the spatial resolution of a NOM-like profilometer corresponding to the first zero-crossing of the optical transform function (OTF) is ~1.2 mm. In this paper, we investigate the performance of an AC ELCOMAT-3000 for a slope profilometer with different aperture sizes and shapes. The results of angular calibration of the AC equipped with circular and rectangular apertures placed at different distances from the AC are discussed. The calibration was performed at the Physikalisch-Technische Bundesanstalt using the original experimental arrangements, also discussed in the paper. The OTF measurements with the specially developed test sample with chirped surface slope profiles were performed at the Advanced Light Source X-Ray Optics Laboratory (XROL) in application to a new optical surface measuring system under development at the XROL. In the OTF measurements, we have shown that application of a rectangular aperture with dimensions of 1.5 mm × 3 mm improves the spatial resolution in the tangential direction by a factor of ~1.4 compared to that of the standard circular aperture of 2.5-mm diameter. We postulate that the conclusions of our investigations are crucial for reaching fundamental metrological limits in deflectometric profilometry utilizing state-of-the-art electronic autocollimators.

47 OTHER INSTRUMENTATION↗