Understanding middle-point inductance's effect on switching transients for multi-chip SiC package design with P-cell/N-cell concept

Middle-point inductance L_middle can be introduced in power module designs with P-cell/N-cell concept. In this paper, the effect of middle-point inductance on switching transients is analyzed first using frequency domain analysis. Then a dedicated multiple-chips power module is fabricated with the capability of varying L_middle, and extensive switching tests are conducted to evaluate the device’s switching performance at different L_middle. Experiment results show that as L_middle changes, different voltage stresses are imposed on the active switch and anti-parallel diode. For lower MOSFET’s turn-off, as L_middle goes up, the maximum voltage of lower MOSFET increases; however, the maximum voltage of anti-parallel diode decreases significantly. In addition to voltage spikes, it is observed that the active MOSFET’s turn-on loss will decrease at higher values of L_middle while its turn-off loss will increase. Detailed analysis of this loss variation is presented. The analysis and experiment results will provide design guidelines for multiple-chips power module package design with P-cell/N-cell concept.

Yang, Fei↗

Development of a low-inductance SiC trench MOSFET power module for high-frequency application

This paper deals with the development of a low-inductance multiple-chip power module with state-of-art 1200 V SiC Trench MOSFETs for high-frequency application. Specifically, a phase-leg power module package with integrated decoupling capacitance is fabricated based on P-cell/N-cell concept, and the packaging design is discussed in detail. Dedicated double pulse test is built, and a gate driver with cross-talk suppression function is designed to support the fast switching speed operation of SiC Trench MOSFETs. The parasitic inductance and current density distribution of the power module are simulated and extracted for the purpose of voltage spike limiting. The temperature dependent static and switching characteristics of the developed module are evaluated as well, and the key differences from traditional SiC double-diffused MOS (DMOS) are identified and discussed. Based on the turn-off switching characterization results, a lumped equivalent power-loop parasitic inductance of ~6 nH is achieved for the designed power module.

Wang, Zhiqiang↗

Umbilical cord-derived mesenchymal stem cells alleviated inflammation and inhibited apoptosis in interstitial cystitis via AKT/mTOR signaling pathway

Highlights: • UC-MSCs alleviated inflammation in rat model and cell model of IC. • UC-MSCs promoted proliferation of urothelium. • UC-MSCs inhibited apoptosis of urothelium. • UC-MSCs activated AKT/mTOR signaling pathway to cure IC. Interstitial cystitis (IC) is a bladder syndrome characterized by pelvic pain and urinary frequency without infection or other identifiable pathology. There are no effective treatments to cure IC. This study investigated the effects of human umbilical cord-derived mesenchymal stem cells (UC-MSCs) injection on IC rat model. Furthermore, we used a coculture system to find the possible molecular mechanism on the human uroepithelial cells (SV-HUC-1), which was the cell model of IC. A rat model of IC was established via systemic injection with cyclophosphamide (CYP) and a cell model of IC was induced by being exposed to tumor necrosis factor (TNF)-α (10 ng/ml). After one week, UC-MSCs injection significantly ameliorated the bladder voiding function in IC rat model. And the Histo- and immunohistochemical analyses showed that UC-MSCs can repair impaired bladder, reduce mast cell infiltration and inhibit apoptosis of urothelium. ELISA results showed that UC-MSCs can decrease IL-1β, IL-6 and TNF-α in bladder. In the coculture system, UC-MSCs can promote proliferation of impaired SV-HUC-1 cells, and inhibit apoptosis. However, while knocked down EGF secreted by UC-MSCs with siRNA, the effects would be weaken. Western blot showed that UC-MSCs increase protein expression levels of p-AKT and p-mTOR in SV-HUC-1 cells, and decrease the levels of cleaved caspase-3. Taken together, we provide evidence that UC-MSCs therapy can successfully alleviate IC in a preclinical animal Model and cell model by alleviating inflammation, promoting proliferation and inhibiting apoptosis. In addition, we demonstrate that the AKT/mTOR signaling pathway was activated.

60 APPLIED LIFE SCIENCES↗

Irisin-mediated protective effect on LPS-induced acute lung injury via suppressing inflammation and apoptosis of alveolar epithelial cells

It is considered that the essence of acute lung injury (ALI) is an excessive and uncontrolled inflammatory response in lung, of which mainly is attributed to the release of inflammatory mediators. Recent studies demonstrated that irisin, which is a metabolism associated factor after physical exercise could suppression of inflammation by regulating cellular signaling pathways, however, the underlying molecular mechanism remains to be determined. The present study aimed to reveal the potential mechanism responsible for the anti-inflammatory effects of irisin on LPS-induced acute lung injury in mice and in A549 cells. The results of histopathological changes showed that irisin ameliorated the lung injury that was induced by LPS in time- and dose-dependent manner. QRT-PCR assays demonstrated that irisin suppressed the production of IL-1β, IL-6, MCP-1 and TNF-α, and western blot assays demonstrated that irisin suppressed apoptosis of ALI. The expression of caspase-3 and Bax were decreased and Bcl-2 was increased by irisin administration. Further study was conducted on nuclear factor (NF)-κB and mitogen-activated protein kinase (MAPK) using pathways using western blots. The results showed that irisin inhibited reduced LPS-induced activation of MAPK and NF-κB signaling. All results indicated that irisin has protective effect on LPS-induced ALI in mice and in A549 cells. Thus, irisn related with physical exercise may be a potential therapy for the treatment of pulmonary inflammation. - Highlights: • Irisin inhibited the inflammation reactivity of cells and pathological changes of LPS-induced lung injury in mice. • Irisin inhibited mRNA expression of inflammatory cytokines induced by LPS in A549 cells. • Irisin inhibited apoptosis induced by LPS in the injured lung. • Irisin reduced LPS-induced activation of MAPK and NF-κB signaling pathways.

60 APPLIED LIFE SCIENCES↗

Design of a low parasitic inductance SiC power module with double-sided cooling

In this paper, a low-parasitic inductance SiC power module with double-sided cooling is designed and compared with a baseline double-sided cooled module. With the unique 3D layout utilizing vertical interconnection, the power loop inductance is effectively reduced without sacrificing the thermal performance. Both simulations and experiments are carried out to validate the design. Q3D simulation results show a power loop inductance of 1.63 nH, verified by the experiment, indicating more than 60% reduction of power loop inductance compared with the baseline module. With 0Ω external gate resistance turn-off at 600V, the voltage overshoot is less than 9% of the bus voltage at a load of 44.6A.

Yang, Fei↗

Load-Dependent Soft-Switching Method of Half-Bridge Current Doubler for High-Voltage Point-of-Load Converter in Data Center Power Supplies

With the increased cloud computing and digital information storage, the energy requirement of data centers keeps increasing. A high-voltage point of load (HV POL) with an input series output parallel structure is proposed to convert 400 to 1 VDC within a single stage to increase the power conversion efficiency. The symmetrical controlled half-bridge current doubler is selected as the converter topology in the HV POL. A load-dependent soft-switching method has been proposed with an auxiliary circuit that includes inductor, diode, and MOSFETs so that the hard-switching issue of typical symmetrical controlled half-bridge converters is resolved. The operation principles of the proposed soft-switching half-bridge current doubler have been analyzed in detail. Then, the necessity of adjusting the timing with the loading in the proposed method is analyzed based on losses, and a controller is designed to realize the load-dependent operation. A lossless RCD current sensing method is used to sense the output inductor current value in the proposed load-dependent operation. In conclusion, experimental efficiency of a hardware prototype is provided to show that the proposed method can increase the converter's efficiency in both heavy- and light-load conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Numerical study of turbulence-influence mechanism on arc characteristics in an air direct current circuit breaker

This paper focuses on the numerical investigation of arc characteristics in an air direct current circuit breaker (air DCCB). Using magneto-hydrodynamics (MHD) theory, 3D laminar model and turbulence model are constructed and calculated. The standard k-epsilon model is utilized to consider the turbulence effect in the arc chamber of the DCCB. Several important phenomena are found: the arc column in the turbulence-model case is more extensive, moves much more slowly than the counterpart in the laminar-model case, and shows stagnation at the entrance of the chamber, unlike in the laminar-model case. Moreover, the arc voltage in the turbulence-model case is much lower than in the laminar-model case. However, the results in the turbulence-model case show a much better agreement with the results of the breaking experiments under DC condition than in the laminar-model case, which is contradictory to the previous conclusions from the arc researches of both the low-voltage circuit breaker and the sulfur hexafluoride (SF6) nozzle. First, in the previous air-arc research of the low-voltage circuit breaker, it is assumed that the air plasma inside the chamber is in the state of laminar, and the laminar-model application gives quite satisfactory results compared with the experiments, while in this paper, the laminar-model application works badly. Second, the turbulence-model application in the arc research of the SF6-nozzle performs much better and gives higher arc voltage than the laminar-model application does, whereas in this paper, the turbulence-model application predicts lower arc voltage than the laminar-model application does. Based on the analysis of simulation results in detail, the mechanism of the above phenomena is revealed. The transport coefficients are strongly changed by turbulence, which will enhance the arc diffusion and make the arc volume much larger. Consequently, the arc appearance and the distribution of Lorentz force in the turbulence-model case substantially differ from the arc appearance and the distribution of Lorentz force in the laminar-model case. Thus, the moving process of the arc in the turbulence-model case is slowed down and slower than in the laminar-model case. Moreover, the more extensive arc column in the turbulence-model case reduces the total arc resistance, which results in a lower arc voltage, more consistent with the experimental results than the arc voltage in the laminar-model case. Therefore, the air plasma inside this air DCCB is believed to be in the turbulence state, and the turbulence model is more suitable than the laminar model for the arc simulation of this kind of air DCCB.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Commissioning optically stimulated luminescence in vivo dosimeters for fast neutron therapy

Purpose: Clinical in vivo dosimeters intended for use with photon and electron therapies have not been utilized for fast neutron therapy because they are highly susceptible to neutron damage. The objective of this work was to determine if a commercial optically stimulated luminescence (OSL) in vivo dosimetry system could be adapted for use in fast neutron therapy. Methods: A 50.5 MeV fast neutron beam generated by a clinical neutron therapy cyclotron was used to irradiate carbon doped aluminum oxide (Al{sub 2}O{sub 3}:C) optically simulated luminescence dosimeters (OSLDs) in a solid water phantom under standard calibration conditions, 150 cm SAD, 1.7 cm depth, and 10.3 × 10.0 cm field size. OSLD fading and electron trap depletion studies were performed with the OSLDs irradiated with 20 and 50 cGy and monitored over a 24-h period to determine the optimal time for reading the dosimeters during calibration. Four OSLDs per group were calibrated over a clinical dose range of 0–150 cGy. Results: OSLD measurement uncertainties were lowered to within ±2%–3% of the expected dose by minimizing the effect of transient fading that occurs with neutron irradiation and maintaining individual calibration factors for each dosimeter. Dose dependent luminescence fading extended beyond the manufacturer’s recommended 10 min period for irradiation with photon or electron beams. To minimize OSL variances caused by inconsistent fading among dosimeters, the observed optimal time for reading the OSLDs postirradiation was between 30 and 90 min. No field size, wedge factor, or gantry angle dependencies were observed in the OSLDs irradiated by the studied fast neutron beam. Conclusions: Measurements demonstrated that uncertainties less than ±3% were attainable in OSLDs irradiated with fast neutrons under clinical conditions. Accuracy and precision comparable to clinical OSL measurements observed with photons can be achieved by maintaining individual OSLD calibration factors and minimizing transient fading effects.

61 RADIATION PROTECTION AND DOSIMETRY↗

Experimental investigation on the electrical contact behavior of rolling contact connector

Rolling contact connector (RCC) is a new technology utilized in high performance electric power transfer systems with one or more rotating interfaces, such as radars, satellites, wind generators, and medical computed tomography machines. Rolling contact components are used in the RCC instead of traditional sliding contacts to transfer electrical power and/or signal. Since the requirement of the power transmission is increasing in these years, the rolling electrical contact characteristics become more and more important for the long-life design of RCC. In this paper, a typical form of RCC is presented. A series of experimental work are carried out to investigate the rolling electrical contact characteristics during its lifetime. The influence of a variety of factors on the electrical contact degradation behavior of RCC is analyzed under both vacuum and air environment. Based on the surface morphology and elemental composition changes in the contact zone, which are assessed by field emission scanning electron microscope and confocal laser scanning microscope, the mechanism of rolling electrical contact degradation is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗