Engineering Papers⌕ Search

Engineering topics

Yang, C

Publications and source records attributed to Yang, C.

At least 37 records · Page 2

SU-E-J-12: A New Stereological Method for Tumor Volume Evaluation for Esophageal Cancer

Purpose: Stereological method used to obtain three dimensional quantitative information from two dimensional images is a widely used tool in the study of cells and pathology. But the feasibility of the method for quantitative evaluation of volumes with 3D image data sets for radiotherapy clinical application has not been explored. On the other hand, a quick, easy-to-use and reliable method is highly desired in image-guided-radiotherapy(IGRT) for tumor volume measurement for the assessment of response to treatment. To meet this need, a stereological method for evaluating tumor volumes for esophageal cancer is presented in this abstract. Methods: The stereology method was optimized by selecting the appropriate grid point distances and sample types. 7 patients with esophageal cancer were selected retrospectively for this study, each having pre and post treatment computed tomography (CT) scans. Stereological measurements were performed for evaluating the gross tumor volume (GTV) changes after radiotherapy and the results was compared with the ones by planimetric measurements. Two independent observers evaluated the reproducibility for volume measurement using the new stereological technique. Results: The intraobserver variation in the GTV volume estimation was 3.42±1.68cm3 (the Wilcoxon matched-pairs test Resultwas Z=−1.726,P=0.084>0.05); the interobserver variation in the GTV volume estimation was 22.40±7.23 cm3 (Z=−3.296,P=0.083>0.05), which showed the consistency in GTV volume calculation with the new method for the same and different users. The agreement level between the results from the two techniques was also evaluated. Difference between the measured GTVs was 20.10±5.35 cm3 (Z=−3.101,P=0.089>0.05). Variation of the measurement results using the two techniques was low and clinically acceptable. Conclusion: The good agreement between stereological and planimetric techniques proves the reliability of the stereological tumor volume estimations. The optimized stereological technique described in this abstract may provide a quick, unbiased and reproducible tool for tumor volume estimation for treatment response assessment. Supported by NSFC (#81041107, #81171342 and #31000784)

60 APPLIED LIFE SCIENCES↗

SU-E-J-190: Characterization of Radiation Induced CT Number Changes in Tumor and Normal Lung During Radiation Therapy for Lung Cancer

Purpose: To measure CT number (CTN) changes in tumor and normal lung as a function of radiation therapy (RT) dose during the course of RT delivery for lung cancer using daily IGRT CT images and single respiration phase CT images. Methods: 4D CT acquired during planning simulation and daily 3D CT acquired during daily IGRT for 10 lung cancer cases randomly selected in terms of age, caner type and stage, were analyzed using an in-house developed software tool. All patients were treated in 2 Gy fractions to primary tumors and involved nodal regions. Regions enclosed by a series of isodose surfaces in normal lung were delineated. The obtained contours along with target contours (GTVs) were populated to each singlephase planning CT and daily CT. CTN in term of Hounsfield Unit (HU) of each voxel in these delineated regions were collectively analyzed using histogram, mean, mode and linear correlation. Results: Respiration induced normal lung CTN change, as analyzed from single-phase planning CTs, ranged from 9 to 23 (±2) HU for the patients studied. Normal lung CTN change was as large as 50 (±12) HU over the entire treatment course, was dose and patient dependent and was measurable with dose changes as low as 1.5 Gy. For patients with obvious tumor volume regression, CTN within the GTV drops monotonically as much as 10 (±1) HU during the early fractions with a total dose of 20 Gy delivered. The GTV and CTN reductions are significantly correlated with correlation coefficient >0.95. Conclusion: Significant RT dose induced CTN changes in lung tissue and tumor region can be observed during even the early phase of RT delivery, and may potentially be used for early prediction of radiation response. Single respiration phase CT images have dramatically reduced statistical noise in ROIs, making daily dose response evaluation possible.

60 APPLIED LIFE SCIENCES↗

SU-E-T-12: A Feasibility Study of Patient Specific QA Using Gafchromic Film of Dynamic Feathering in Junctions of Craniospinal Irradiation

Purpose: Cranio-spinal irradiation is the most complicated format of the conventional external beam radiation therapy because it involves matches of non-coplanar beams which are susceptible to daily setup errors. This study explores the efficacy of Gafchromic film dosimetry to quantitatively verify the junctions for cranio-spinal radiation feathered with field in field technique. Methods: 15cm in thickness of solid water phantom was scanned vertically and exported to the Pinnacle TPS as primary phantom data set. A patient cranio-spinal plan, consisted of two bilateral whole brain beams dynamically matched with a posterior spinal beam using field in field technique, was transferred to the phantom and recalculated for one fraction with set monitor units identical to the original plan. Next, planar dose distribution on the phantom was exported to the FilmQA Pro 2013 software (Ashland, Inc.) in binary format for comparison with the measured dose distribution. An EBT2 film was sandwiched in the middle of the phantom and the phantom was set up according to the QA plan based on the room laser system. The shifts instructions associated with the patient original plan were made and the beams from the patient original plan delivered to the solid water phantom via the record and verify system in QA mode. The dose distribution from the measured film was compared with the planned reference distribution using gamma analysis and profile comparison. Results: Gamma passing rate of 91 % with DTA 3mm and 5% dose difference was obtained within the junction region, significantly greater passing rate above 95 % was obtained in the homogeneous region of the brain field. Conclusion: This study confirms that Gafchromic film dosimetry can be used to validate the efficacy of FIF feathering technique for cranio-spinal treatment. FIF technique with Gafchromic dosimetry may now be the new standard for delivering efficient and accurate cranio-spinal radiation with confidence.

60 APPLIED LIFE SCIENCES↗

SU-E-T-40: Analysis of Composite MVCT Planning Dosimetry with SBRT of Upper Peripheral Lung Cancer

Purpose: Quantitatively evaluate and compare the final adaptive planning doses of upper peripherally located lung SBRT treated with Tomotherapy using 3rd party software tool. Methods: With tumor located in the upper quadrant of lung, a 3rd party software tool was implemented to evaluate the Tomotherapy composite dosimetry created by adaptive fan beam MVCT images described by RTOG 0915 dose criteria (48 Gy / 4 fractions). The composite doses was then summarized with deformable registration in this package with corresponding target and critical structures. The final dosimetry variation, both for target and critical structures, were evaluated in a tabular format and isodose distribution comparisons. Results: Composite SBRT treatment doses were evaluated with adaptive planning. The PTV and several critical structures were mapped/deformed into the package via DICOM from Tomotherapy after the final composite doses were created. Initial plan versus the final composite plan calculated from verification images were compared. The ITV defined by 4D CT and contoured on MVCT images were correlated in patient repositioning. Final composite dose calculated for PTV coverage has shown 0.1–0.17 cGy coverage (0.2–0.4% of prescription dose) variation. Total lung and cord were both less than 0.17 Gy which represented <0.4% difference. All other critical structure were within statistical significance. The adaptive plans justified/included the breathing and motion during the treatment process. Final 95% isotope line coverage from prescription has been met without issues. Conclusions: With lung tumor location in the upper peripheral area, breathing control was not necessary required during SBRT treatment using Tomotherapy technique. Slow fan beam CT provides definitive ITV information and the adaptive composite plan for all fractions were suitable for final dose delivery. The final composite dose calculated with Tomotherapy adaptive tool indicated that the composite dosimetry justified the target location with SBRT delivery, safe with minimum margin of errors.

60 APPLIED LIFE SCIENCES↗

SU-E-T-204: Improving Multiple Isocenter Coincidence: Elekta Beam Modulator with HexaPOD Six Degrees Couchtop

Purpose: With evolution from frame-based to image-guided SRS/SRT technique, the coincidence of multiple isocenters must be within a tight tolerance: MV, kV, table mechanical, and, in this case, HexaPOD 6° patient positioning system. Reported here is a method for improving the effectiveness of an isocenter alignment procedure which ultimately led to isocenter coincidence on an Elekta Beam Modulator LINAC equipped with 4 mm MLC leaves and a fixed secondary jaw to within a radius of 1mm. Methods: Utilizing a self-leveling laser, the Elekta ball (BB) bearing phantom (8mm steel ball), the Modus QA Isocenter Cube software, and a colleague-provided isocenter alignment method, the kV, table mechanical, and HexaPOD isocenters were localized to the MV isocenter. Isocenter coincidence was tested using the Isocenter Cube from Modus QA, brought to kV isocenter using CBCT and the HexaPOD system. MV images were taken at various gantry, collimator, and couch angles and then analyzed with the aforementioned software to determine coincidence of the 5mm steel ball at cube center with MV isocenter. To improve overall coincidence, two errors were addressed iteratively: (1) LINAC mechanical and radiation isocenter coincidence allowing each isocenter volume to have similar variations during gantry and collimator rotation and (2) collimator rotational walkout which reduced the size of both mechanical and radiation isocenters. Beam steering was performed to bring MV isocenter closer to mechanical and collimator walkout was adjusted by physically shifting the MLC bank. Initial procedures were repeated to align all isocenters and perform regular checks for consistency. Results: Post-initial alignment revealed a maximum diameter of 1.8mm for MV isocenter and maximum isocenter alignment error of up to 1.22mm radius which improved to roughly 1.0mm MV isocenter diameter and <0.71mm radius alignment error with a consistency within 0.25mm. Conclusion: With the methods described, all isocenters were brought into alignment within a radius of 1mm.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-331: To Evaluate Planning Quality of SBRT with Multiple Lung Metastases Generated with Pinnacle and Tomotherapy

Purpose: To evaluate planning quality of SBRT with multiple lung metastases generated with Pinnacle and Tomotherapy Methods: Nine randomly selected patients diagnosed with non small-cell lung cancer with multiple lesions were planned with Pinnacle (version 9.2) and Tomotherapy (version 4.2). Coplanar and non-coplanar plans were generated on Pinnacle. A total dose of 60 Gy was prescribed to 95% of PTV in 3 fractions. Single isocenter was used. Nine static beams were used for Pinnacle plans. Planning outcomes such as minimum and mean dose, V{sub 9} {sub 5}, D{sub 9} {sub 5} (95% of target volume receives prescription dose), D{sub 5}, and D{sub 1} to PTV, maximum dose to heart, esophagus, cord, trachea, brachial plexus, rib, chest wall, and liver, mean dose to liver, total lung, right and left lung, volume of chest wall receives 30 Gy, volume of lungs receives 5 Gy and 20Gy, conformity index (CI = PIV / PTV) and heterogeneity index (HI = D{sub 5} / D{sub 9} {sub 5}) were reported for evaluation. Results: The mean volume of PTV was 37.77 ± 23.4 cm3. D{sub 9} {sub 5} of PTV with Tomo, coplanar, non-coplanar was 60.2 ± 0.3 Gy, 58.6 ± 1.2 Gy, and 59.1 ± 0.7 Gy, respectively. Mean dose to PTV was lower for Tomo (p < 0.0001), so were D{sub 5} (p < 0.0001) and D{sub 1} (p = 0.001). CI was better with Tomo (p < 0.0001), so was HI (p < 0.0001). Maximum dose to other critical organs were also lower exclusively with Tomo plans. Treatment time was recorded only for Tomo plans (73.0 ± 20.6 min). Conclusion: With 51 beam angles, Tomo plans could generally achieve better tumor coverage while sparing more critical structures for multiple lung lesions study. Non-coplanar also has better tumor coverage with lower dose to critical organs such as lungs, liver, chest wall and cord compare to coplanar plans.

60 APPLIED LIFE SCIENCES↗

Wakefields in photonic accelerator structures

Control and manipulation of properties - such as vacuum modal confinement, spatial harmonic content, phase velocity, and group velocity - are reasons why an all-dielectric beam-driven accelerator would be expected to benefit by borrowing from the field of optical bandgap photonics. We outline the general conditions for coherent Cerenkov radiation in a photonic crystal, illustrated by three examples: two Bragg mirrors separated by a vacuum gap, a woodpile with a linear waveguide channel, and a stack of photonic slabs having a planar waveguide channel.

43 PARTICLE ACCELERATORS↗

Ab-Initio Hamiltonian Approach to Light Nuclei And to Quantum Field Theory

Nuclear structure physics is on the threshold of confronting several long-standing problems such as the origin of shell structure from basic nucleon-nucleon and three-nucleon interactions. At the same time those interactions are being developed with increasing contact to QCD, the underlying theory of the strong interactions, using effective field theory. The motivation is clear - QCD offers the promise of great predictive power spanning phenomena on multiple scales from quarks and gluons to nuclear structure. However, new tools that involve non-perturbative methods are required to build bridges from one scale to the next. We present an overview of recent theoretical and computational progress with a Hamiltonian approach to build these bridges and provide illustrative results for the nuclear structure of light nuclei and quantum field theory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A High-Performance Rechargeable Iron Electrode for Large-Scale Battery-Based Energy Storage

Inexpensive, robust and efficient large-scale electrical energy storage systems are vital to the utilization of electricity generated from solar and wind resources. In this regard, the low cost, robustness, and eco-friendliness of aqueous iron-based rechargeable batteries are particularly attractive and compelling. However, wasteful evolution of hydrogen during charging and the inability to discharge at high rates have limited the deployment of iron-based aqueous batteries. We report here new chemical formulations of the rechargeable iron battery electrode to achieve a ten-fold reduction in the hydrogen evolution rate, an unprecedented charging efficiency of 96%, a high specific capacity of 0.3 Ah/g, and a twenty-fold increase in discharge rate capability. We show that modifying high-purity carbonyl iron by in situ electro-deposition of bismuth leads to substantial inhibition of the kinetics of the hydrogen evolution reaction. The in situ formation of conductive iron sulfides mitigates the passivation by iron hydroxide thereby allowing high discharge rates and high specific capacity to be simultaneously achieved. These major performance improvements are crucial to advancing the prospect of a sustainable large-scale energy storage solution based on aqueous iron-based rechargeable batteries. (C) 2012 The Electrochemical Society. [DOI: 10.1149/2.034208jes] All rights reserved.

Manohar, AK↗

Effect of Si doping and applied pressure upon magnetostructural properties of Tb5(SixGe1−x)4 magnetocaloric compounds

The composition- and pressure-dependent magnetostructural properties of Tb{sub 5}(Si{sub x}Ge{sub 1-x}){sub 4} (x = 0.4, 0.485, 0.625, and 0.7) were investigated using x-ray powder diffraction and x-ray magnetic circular dichroism in a diamond anvil cell, respectively. Substituting the smaller-size Si for Ge stabilizes a single-phase, ferromagnetic (FM) orthorhombic O(I) structure for x ? 0.7. Similarly, application of external pressure causes a canted antiferromagnetic orthorhombic O(II) sample (x = 0.4) to transform into an FM O(I) phase at 4 GPa. The element- and orbital-specific x-ray absorption data indicate that the Tb 4f orbital occupation changes with external pressure, likely through 4f-5d electronic mixing, yet no changes in Tb 4f electronic structure are observed with Si doping. The results point to different mechanisms behind the enhancement of FM exchange interactions in Tb{sub 5}(Si{sub x}Ge{sub 1-x}){sub 4} with chemical and applied pressure, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Observability of radiation-pressure shot noise in optomechanical systems

We present a theoretical study of an experiment designed to detect radiation-pressure shot noise in an optomechanical system. Our model consists of a coherently driven optical cavity mode that is coupled to a mechanical oscillator. We examine the cross-correlation between two quadratures of the output field from the cavity. We determine under which circumstances radiation-pressure shot noise can be detected by a measurement of this cross-correlation. This is done in the general case of nonzero detuning between the frequency of the drive and the cavity resonance frequency. We study the qualitative features of the different contributions to the cross-correlator and provide quantitative figures of merit for the relative importance of the radiation-pressure shot noise contribution to other contributions. We also propose a modified setup of this experiment relevant to the 'membrane-in-the-middle' geometry, which potentially can avoid the problems of static bistability and classical noise in the drive.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hamiltonian light-front field theory in a basis function approach

Hamiltonian light-front quantum field theory constitutes a framework for the nonperturbative solution of invariant masses and correlated parton amplitudes of self-bound systems. By choosing the light-front gauge and adopting a basis function representation, a large, sparse, Hamiltonian matrix for mass eigenstates of gauge theories is obtained that is solvable by adapting the ab initio no-core methods of nuclear many-body theory. Full covariance is recovered in the continuum limit, the infinite matrix limit. There is considerable freedom in the choice of the orthonormal and complete set of basis functions with convenience and convergence rates providing key considerations. Here we use a two-dimensional harmonic oscillator basis for transverse modes that corresponds with eigensolutions of the soft-wall anti-de Sitter/quantum chromodynamics (AdS/QCD) model obtained from light-front holography. We outline our approach and present illustrative features of some noninteracting systems in a cavity. We illustrate the first steps toward solving quantum electrodynamics (QED) by obtaining the mass eigenstates of an electron in a cavity in small basis spaces and discuss the computational challenges.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dependence of Pentacene Crystal Growth on Dielectric Roughness for Fabrication of Flexible Field-Effect Transistors

The dependence of pentacene nanostructures on gate dielectric surfaces were investigated for flexible organic field-effect transistor (OFET) applications. Two bilayer types of polymer/aluminum oxide (Al{sub 2}O{sub 3}) gate dielectrics were fabricated on commercial Al foils laminated onto a polymer back plate. Some Al foils were directly used as gate electrodes, and others were smoothly polished by an electrolytic etching. These Al surfaces were then anodized and coated with poly({alpha}-methyl styrene) (PAMS). For PAMS/Al{sub 2}O{sub 3} dielectrics onto etched Al foils, surface roughness up to 1 nm could be reached, although isolated dimples with a lateral diameter of several micrometers were still present. On PAMS/Al{sub 2}O{sub 3} dielectrics (surface roughness >40 nm) containing mechanical grooves of Al foil, average hole mobility ({mu}FET) of 50 nm thick pentacene-FETs under the low operating voltages (|V| < 6 V) was {approx}0.15 cm{sup 2} V{sup -1} s{sup -1}. In contrast, pentacene-FETs employing the etched Al gates exhibited {mu}FET of 0.39 cm{sup 2} V{sup -1} s{sup -1}, which was comparable to that of reference samples with PAMS/Al{sub 2}O{sub 3} dielectrics onto flat sputtered Al gates. Conducting-probe atomic force microscopy and two-dimensional X-ray diffraction of pentacene films with various thicknesses revealed different out-of-plane and in-plane crystal orderings of pentacene, depending on the surface roughness of the gate dielectrics.

36 MATERIALS SCIENCE↗

Isothermal Crystallization of Poly(L-lactide) Induced by Graphene Nanosheets and Carbon Nanotubes: A Comparative Study

Low-dimensional nanoparticles have a strong ability to induce the crystallization of polymer matrices. One-dimensional carbon nanotubes (CNTs) and two-dimensional graphene nanosheets (GNSs), both of which are both carbon-based nanoparticles, provide a good opportunity to investigate the effects of differently dimensional nanoparticles on the crystallization behavior of a polymer. For this purpose, respective nanocomposites of CNTs and GNSs with poly(L-lactide) (PLLA) as matrix were prepared by solution coagulation. Time-resolved Fourier-transform infrared spectroscopy (FTIR) and synchrotron wide-angle X-ray diffraction (WAXD) were performed to probe chain conformational changes and to determine the crystallization kinetics during the isothermal crystallization of the PLLA nanocomposites and neat PLLA, especially in the early stages. Both CNTs and GNSs could serve as nucleating agents in accelerating the crystallization kinetics of PLLA; however, the ability of CNTs to induce crystallization was stronger than that of GNSs. On increasing the content of CNTs from 0.05 to 0.1 wt %, the induction period was shortened and the crystallization rate was enhanced, but the reverse situation was found for GNSs nanocomposites. In the case of neat PLLA, -CH{sub 3} interchain interactions preceded -(COC + CH{sub 3}) interchain interactions during the crystallization. Conversely, in the CNTs and GNSs nanocomposites, the conformational ordering began with -(COC + CH{sub 3}) interchain interactions, which resulted directly in a reduced induction period. Interchain interactions of this type could be explained in terms of surface-induced conformational order (SICO). Finally, the effect of the dimensionality of the nanoparticles on the crystallization behavior of PLLA is discussed.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Hamiltonian Light-front Field Theory Within an AdS/QCD Basis

Non-perturbative Hamiltonian light-front quantum field theory presents opportunities and challenges that bridge particle physics and nuclear physics. Fundamental theories, such as Quantum Chromodynamics (QCD) and Quantum Electrodynamics (QED) offer the promise of great predictive power spanning phenomena on all scales from the microscopic to cosmic scales, but new tools that do not rely exclusively on perturbation theory are required to make connection from one scale to the next. We outline recent theoretical and computational progress to build these bridges and provide illustrative results for nuclear structure and quantum field theory. As our framework we choose light-front gauge and a basis function representation with two-dimensional harmonic oscillator basis for transverse modes that corresponds with eigensolutions of the soft-wall AdS/QCD model obtained from light-front holography.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Impact of kerogen heterogeneity on sorption of organic pollutants. 1. Sorbent characterization

The overall goal of the present study was to establish correlations between organic pollutant sorption and physicochemical properties of kerogen materials. Three coal samples, each representing a typical kerogen type, were used as the starting materials. A thermal technique was employed to treat the kerogen materials under seven different temperatures ranging from 200 to 500{sup o}C to simulate different diagenetic history. These samples were systematically characterized for their chemical compositions, functionalities, physical rigidity, and optical properties. The results showed that the chemical, spectroscopic, and optical microscopic properties of each kerogen series changed consistently as a function of treatment temperature or kerogen maturation. The oxygen-to-carbon atomic ratio decreased from 0.29, 0.12, and 0.07 for the original lignite (XF0), fusinite (HZ0), and lopinite (LP0) samples, respectively, to 0.07, 0.06, and 0.04 for XF7, HZ7, and LP7, respectively, that underwent the highest temperature treatment. The hydrogen-to-carbon atomic ratio exhibited similar reducing trend, which is consistent with the aromaticity increasing from 45 to 58% of the original samples to 76 to 81% of highly mature samples. The measured reflecting index increased from the original samples to the highly mature samples. Moreover, the original and the slightly matured samples exhibited very different chemical compositions and structural units among the three types due to the difference in their source materials. As the kerogen maturation increased, such differences decreased, indicating highly mature kerogen became homogenized regardless of the source material.

01 COAL, LIGNITE, AND PEAT↗