Engineering Papers⌕ Search

Engineering topics

Yan, Zhuang

Publications and source records attributed to Yan, Zhuang.

HSPB1 Gene Polymorphisms Predict Risk of Mortality for US Patients After Radio(chemo)therapy for Non-Small Cell Lung Cancer

Purpose: We investigated potential associations between single-nucleotide polymorphisms (SNPs) in the heat shock protein beta-1 (HSPB1) gene and overall survival in US patients with non-small cell lung cancer (NSCLC). Methods and Materials: Using available genomic DNA samples from 224 patients with NSCLC treated with definitive radio(chemo)therapy, we genotyped 2 SNPs of HSPB1 (NCBI SNP nos. rs2868370 and rs2868371). We used both Kaplan-Meier cumulative probability and Cox proportional hazards analyses to evaluate the effect of HSPB1 genotypes on survival. Results: Our cohort consisted of 117 men and 107 women, mostly white (79.5%), with a median age of 70 years. The median radiation dose was 66 Gy (range, 63-87.5 Gy), and 183 patients (82%) received concurrent platinum-based chemotherapy. The most common genotype of the rs2868371 SNP was CC (61%). Univariate and multivariate analyses showed that this genotype was associated with poorer survival than CG and GG genotypes (univariate hazard ratio [HR] = 1.39, 95% confidence interval [CI], 1.02-1.90; P=.037; multivariate HR = 1.39; 95% CI, 1.01-1.92; P=.045). Conclusions: Our results showed that the CC genotype of HSPB1 rs2868371 was associated with poorer overall survival in patients with NSCLC after radio(chemo)therapy, findings that contradict those of a previous study of Chinese patients. Validation of our findings with larger numbers of similar patients is needed, as are mechanical and clinical studies to determine the mechanism underlying these associations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Change in Diffusing Capacity After Radiation as an Objective Measure for Grading Radiation Pneumonitis in Patients Treated for Non-Small-Cell Lung Cancer

Purpose: Scoring of radiation pneumonitis (RP), a dose-limiting toxicity after thoracic radiochemotherapy, is subjective and thus inconsistent among studies. Here we investigated whether the extent of change in diffusing capacity of the lung for carbon monoxide (DLCO) after radiation therapy (RT) for non-small-cell lung cancer (NSCLC) could be used as an objective means of quantifying RP. Patients and Methods: We analyzed potential correlations between DLCO and RP in 140 patients who received definitive RT ({>=}60 Gy) with or without chemotherapy for primary NSCLC. All underwent DLCO analysis before and after RT. Post-RT DLCO values within 1 week of the RP diagnosis (Grade 0, 1, 2, or 3) were selected and compared with that individual's preradiation values. Percent reductions in DLCO and RP grade were compared by point biserial correlation in the entire patient group and in subgroups stratified according to various clinical factors. Results: Patients experiencing Grade 0, 1, 2, or 3 RP had median percentage changes in DLCO after RT of 10.7%, 13%, 22.1%, or 35.2%. Percent reduction in DLCO correlated with RP Grade {<=}1 vs. {>=}2 (p = 0.0004). This association held for the following subgroups: age {>=}65 years, advanced stage, smokers, use of chemotherapy, volume of normal lung receiving at least 20 Gy {>=}30%, and baseline DLCO or forced expiratory volume in 1 second {>=}60%. Conclusions: By correlating percent change in DLCO from pretreatment values at the time of diagnosis of RP with RP grade, we were able to identify categories of RP based on the change in DLCO. These criteria provide a basis for an objective scoring system for RP based on change in DLCO.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Changes in Pulmonary Function After Three-Dimensional Conformal Radiotherapy, Intensity-Modulated Radiotherapy, or Proton Beam Therapy for Non-Small-Cell Lung Cancer

Purpose: To investigate the extent of change in pulmonary function over time after definitive radiotherapy for non-small-cell lung cancer (NSCLC) with modern techniques and to identify predictors of changes in pulmonary function according to patient, tumor, and treatment characteristics. Patients and Methods: We analyzed 250 patients who had received {>=}60 Gy radio(chemo)therapy for primary NSCLC in 1998-2010 and had undergone pulmonary function tests before and within 1 year after treatment. Ninety-three patients were treated with three-dimensional conformal radiotherapy, 97 with intensity-modulated radiotherapy, and 60 with proton beam therapy. Postradiation pulmonary function test values were evaluated among individual patients compared with the same patient's preradiation value at the following time intervals: 0-4 (T1), 5-8 (T2), and 9-12 (T3) months. Results: Lung diffusing capacity for carbon monoxide (DLCO) was reduced in the majority of patients along the three time periods after radiation, whereas the forced expiratory volume in 1 s per unit of vital capacity (FEV1/VC) showed an increase and decrease after radiation in a similar percentage of patients. There were baseline differences (stage, radiotherapy dose, concurrent chemotherapy) among the radiation technology groups. On multivariate analysis, the following features were associated with larger posttreatment declines in DLCO: pretreatment DLCO, gross tumor volume, lung and heart dosimetric data, and total radiation dose. Only pretreatment DLCO was associated with larger posttreatment declines in FEV1/VC. Conclusions: Lung diffusing capacity for carbon monoxide is reduced in the majority of patients after radiotherapy with modern techniques. Multiple factors, including gross tumor volume, preradiation lung function, and dosimetric parameters, are associated with the DLCO decline. Prospective studies are needed to better understand whether new radiation technology, such as proton beam therapy or intensity-modulated radiotherapy, may decrease the pulmonary impairment through greater lung sparing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-Term Clinical Outcome of Intensity-Modulated Radiotherapy for Inoperable Non-Small Cell Lung Cancer: The MD Anderson Experience

Purpose: In 2007, we published our initial experience in treating inoperable non-small-cell lung cancer (NSCLC) with intensity-modulated radiation therapy (IMRT). The current report is an update of that experience with long-term follow-up. Methods and Materials: Patients in this retrospective review were 165 patients who began definitive radiotherapy, with or without chemotherapy, for newly diagnosed, pathologically confirmed NSCLC to a dose of {>=}60 Gy from 2005 to 2006. Early and late toxicities assessed included treatment-related pneumonitis (TRP), pulmonary fibrosis, esophagitis, and esophageal stricture, scored mainly according to the Common Terminology Criteria for Adverse Events 3.0. Other variables monitored were radiation-associated dermatitis and changes in body weight and Karnofsky performance status. The Kaplan-Meier method was used to compute survival and freedom from radiation-related acute and late toxicities as a function of time. Results: Most patients (89%) had Stage III to IV disease. The median radiation dose was 66 Gy given in 33 fractions (range, 60-76 Gy, 1.8-2.3 Gy per fraction). Median overall survival time was 1.8 years; the 2-year and 3-year overall survival rates were 46% and 30%. Rates of Grade {>=}3 maximum TRP (TRP{sub max}) were 11% at 6 months and 14% at 12 months. At 18 months, 86% of patients had developed Grade {>=}1 maximum pulmonary fibrosis (pulmonary fibrosis{sub max}) and 7% Grade {>=}2 pulmonary fibrosis{sub max}. The median times to maximum esophagitis (esophagitis{sub max}) were 3 weeks (range, 1-13 weeks) for Grade 2 and 6 weeks (range, 3-13 weeks) for Grade 3. A higher percentage of patients who experienced Grade 3 esophagitis{sub max} later developed Grade 2 to 3 esophageal stricture. Conclusions: In our experience, using IMRT to treat NSCLC leads to low rates of pulmonary and esophageal toxicity, and favorable clinical outcomes in terms of survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Active vibration damping using smart material

We consider the modeling and active damping of an elastic beam using distributed actuators and sensors. The piezoelectric ceramic material (PZT) is used to build the actuator. The sensor is made of the piezoelectric polymer polyvinylidene fluoride (PVDF). These materials are glued on both sides of the beam. For the simple clamped beam, the closed loop controller has been shown to be able to extract energy from the beam. The shape of the actuator and its influence on the closed loop system performance are discussed. It is shown that it is possible to suppress the selected mode by choosing the appropriate actuator layout. It is also shown that by properly installing the sensor and determining the sensor shape we can further extract and manipulate the sensor signal for our control need.

Baras, John S.↗