Engineering Papers⌕ Search

Engineering topics

Yan, X.

Publications and source records attributed to Yan, X..

The PRad windowless gas flow target

In this work, we report on a windowless, high-density, gas flow target at Jefferson Lab that was used to measure $r_p$, the root-mean-square charge radius of the proton. To our knowledge, this is the first such system used in a fixed-target experiment at a (non-storage ring) electron accelerator. The target achieved its design goal of an areal density of 2$\times$10$^{18}$ atoms/cm$^2$, with the gas uniformly distributed over the 4 cm length of the cell and less than 1% residual gas outside the cell. This design eliminated scattering from the end caps of the target cell, a problem endemic to previous measurements of the proton charge radius in electron scattering experiments, and permitted a precise, model-independent extraction of $r_p$ by reaching unprecedentedly low values of $Q^2$, the square of the electron's transfer of four-momentum to the proton.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First measurement of the asymmetry and the Gerasimov-Drell-Hearn integrand from the 3 $\vec{H}$e ($\vec{γ},p$) 2 H reaction at an incident photon energy of 29 MeV

The first measurement of the 3 $\vec{H}$e ($\vec{γ},p$) 2 H process was performed at the High Intensity γ-ray Source ( HIγS ) facility at Triangle Universities Nuclear Laboratory using a circularly polarized, monoenergetic γ -ray beam and a longitudinally polarized 3 He target. The spin-dependent asymmetry and the contribution from the two-body photodisintegration to the 3 He Gerasimov-Drell-Hearn integrand are extracted and compared with state-of-the-art three-nucleon system calculations at the incident photon energy of 29 MeV. The data are in general agreement with the various theoretical predictions based on the Siegert theorem or on explicit inclusion of meson-exchange currents.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Aperture, A Large Telescope Using Magnetostriction For Post Deployment Corrections: Final Technical Report of NASA Innovative Advanced Concepts (NIAC) Phase I

In summary, astronomical as well as Earth observing applications of the future are counting on larger aperture telescopes than are currently available. Several groups have been working on the topic of enabling large (about 16-m diameter) UV-Vis telescopes for many years. The unique feature of our concept is that magnetic films are used rather than electrostatic films or piezo-electrostatic pads. Our magnetic film concept allows for contiguous correction along the surface, does not require a hard wire connection, and does not require continuous external application of the field. There are many unknowns related to the initial accuracy of the deployed figure prior to the magnetic write head corrections. The length scale over which the corrections need to be applied is also of concern. For, although approximately mm length scale corrections can be made with the MSM plus write head technology, the number of 1 mm² patches in a 16 m diameter mirror is too large to contemplate applying individual corrections to each individual patch. However, deployment strategies and the materials available continue to evolve, in particular shape memory composites (SMCs) [34] or alloys (SMAs) [41], such that at this time we see no show-stoppers for this concept. Furthermore, the ability to tune deformations down to much (factors of 10-100) smaller (m) scale opens the futuristic possibility of improving the figure well beyond Strehl values of 90%.

APERTURE↗

Contractile reserve and intracellular calcium regulation in mouse myocytes from normal and hypertrophied failing hearts

Mouse myocyte contractility and the changes induced by pressure overload are not fully understood. We studied contractile reserve in isolated left ventricular myocytes from mice with ascending aortic stenosis (AS) during compensatory hypertrophy (4-week AS) and the later stage of early failure (7-week AS) and from control mice. Myocyte contraction and [Ca(2+)](i) transients with fluo-3 were measured simultaneously. At baseline (0.5 Hz, 1.5 mmol/L [Ca(2+)](o), 25 degrees C), the amplitude of myocyte shortening and peak-systolic [Ca(2+)](i) in 7-week AS were not different from those of controls, whereas contraction, relaxation, and the decline of [Ca(2+)](i) transients were slower. In response to the challenge of high [Ca(2+)](o), fractional cell shortening was severely depressed with reduced peak-systolic [Ca(2+)](i) in 7-week AS compared with controls. In response to rapid pacing stimulation, cell shortening and peak-systolic [Ca(2+)](i) increased in controls, but this response was depressed in 7-week AS. In contrast, the responses to both challenge with high [Ca(2+)](o) and rapid pacing in 4-week AS were similar to those of controls. Although protein levels of Na(+)-Ca(2+) exchanger were increased in both 4-week and 7-week AS, the ratio of SR Ca(2+)-ATPase to phospholamban protein levels was depressed in 7-week AS compared with controls but not in 4-week AS. This was associated with an impaired capacity to increase sarcoplasmic reticulum Ca(2+) load during high work states in 7-week AS myocytes. In hypertrophied failing mouse myocytes, depressed contractile reserve is related to an impaired augmentation of systolic [Ca(2+)](i) and SR Ca(2+) load and simulates findings in human failing myocytes.

Non-NASA Center↗

Left ventricular hypertrophy in ascending aortic stenosis mice: anoikis and the progression to early failure

BACKGROUND: To determine potential mechanisms of the transition from hypertrophy to very early failure, we examined apoptosis in a model of ascending aortic stenosis (AS) in male FVB/n mice. METHODS AND RESULTS: Compared with age-matched controls, 4-week and 7-week AS animals (n=12 to 16 per group) had increased ratios of left ventricular weight to body weight (4.7+/-0.7 versus 3.1+/-0.2 and 5. 7+/-0.4 versus 2.7+/-0.1 mg/g, respectively, P<0.05) with similar body weights. Myocyte width was also increased in 4-week and 7-week AS mice compared with controls (19.0+/-0.8 and 25.2+/-1.8 versus 14. 1+/-0.5 microm, respectively, P<0.01). By 7 weeks, AS myocytes displayed branching with distinct differences in intercalated disk size and staining for beta(1)-integrin on both cell surface and adjacent extracellular matrix. In vivo left ventricular systolic developed pressure per gram as well as endocardial fractional shortening were similar in 4-week AS and controls but depressed in 7-week AS mice. Myocyte apoptosis estimated by in situ nick end-labeling (TUNEL) was extremely rare in 4-week AS and control mice; however, a low prevalence of TUNEL-positive myocytes and DNA laddering were detected in 7-week AS mice. The specificity of TUNEL labeling was confirmed by in situ ligation of hairpin oligonucleotides. CONCLUSIONS: Our findings indicate that myocyte apoptosis develops during the transition from hypertrophy to early failure in mice with chronic biomechanical stress and support the hypothesis that the disruption of normal myocyte anchorage to adjacent extracellular matrix and cells, a process called anoikis, may signal apoptosis.

NASA Discipline Cardiopulmonary↗