Engineering Papers⌕ Search

Engineering topics

Yamamoto, Masaki

Publications and source records attributed to Yamamoto, Masaki.

Remote access and automation of SPring-8 MX beamlines

At SPring-8 MX beamlines, a remote access system has been developed and started user operation in 2010. The system has been developed based on an automated data collection and data management architecture utilized for the confirmed scheme of SPring-8 mail-in data collection. Currently, further improvement to the remote access and automation which covers data processing and analysis are being developed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TAKASAGO-6 apparatus for cryogenic coherent X-ray diffraction imaging of biological non-crystalline particles using X-ray free electron laser at SACLA

Coherent X-ray diffraction imaging (CXDI) is a technique for structure analyses of non-crystalline particles with dimensions ranging from micrometer to sub-micrometer. We have developed a diffraction apparatus named TAKASAGO-6 for use in single-shot CXDI experiments of frozen-hydrated non-crystalline biological particles at cryogenic temperature with X-ray free electron laser pulses provided at a repetition rate of 30 Hz from the SPring-8 Angstrom Compact free-electron LAser. Specimen particles are flash-cooled after being dispersed on thin membranes supported by specially designed disks. The apparatus is equipped with a high-speed translation stage with a cryogenic pot for raster-scanning of the disks at a speed higher than 25 μm/33 ms. In addition, we use devices assisting the easy transfer of cooled specimens from liquid-nitrogen storages to the cryogenic pot. In the current experimental procedure, more than 20 000 diffraction patterns can be collected within 1 h. Here we report the key components and performance of the diffraction apparatus. Based on the efficiency of the diffraction data collection and the structure analyses of metal particles, biological cells, and cellular organelles, we discuss the future application of this diffraction apparatus for structure analyses of biological specimens.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A ferromagnetic compound with anti-cancer proeprties for controlled drug delivery and imaging

New anticancer agents and modalities for their use are of great interest. Recent studies have demonstrated the presence of anti-cancer properties in salen derivatives. We found that an iron salen derivative, i.e., [Fe(salen)] 2 O, displays ferromagnetic order above room temperature and shows spontaneous field-dependent magnetization and hysteresis. Understanding of this magnetic property is provided by first-principles calculations based on structures obtained by X-ray crystallography. [Fe(salen)] 2 O exhibited potent anti-cancer properties against various cancer cell types and was readily attracted by even moderate-strength permanent magnets in vitro. We demonstrated that the delivery of [Fe(salen)] 2 O to melanoma tissues transplanted into the tails of mice using a permanent magnet leads to a robust decrease in tumor size. The local accumulation of [Fe(salen)] 2 O was visualized by MRI. Thus, [Fe(salen)] 2 O acted as an anti-cancer and MRI contrast compound that has a pharmacological effect that is delivered in a controlled manner, suggesting new strategies for anti-cancer drug development.

60 APPLIED LIFE SCIENCES↗

KOTOBUKI-1 apparatus for cryogenic coherent X-ray diffraction imaging

We have developed an experimental apparatus named KOTOBUKI-1 for use in coherent X-ray diffraction imaging experiments of frozen-hydrated non-crystalline particles at cryogenic temperature. For cryogenic specimen stage with small positional fluctuation for a long exposure time of more than several minutes, we here use a cryogenic pot cooled by the evaporation cooling effect for liquid nitrogen. In addition, a loading device is developed to bring specimens stored in liquid nitrogen to the specimen stage in vacuum. The apparatus allows diffraction data collection for frozen-hydrated specimens at 66 K with a positional fluctuation of less than 0.4 μm and provides an experimental environment to easily exchange specimens from liquid nitrogen storage to the specimen stage. The apparatus was developed and utilized in diffraction data collection of non-crystalline particles with dimensions of μm from material and biological sciences, such as metal colloid particles and chloroplast, at BL29XU of SPring-8. Recently, it has been applied for single-shot diffraction data collection of non-crystalline particles with dimensions of sub-μm using X-ray free electron laser at BL3 of SACLA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Suppressive effects of acid-forming diet against the tumorigenic potential of pioglitazone hydrochloride in the urinary bladder of male rats

Pioglitazone hydrochloride (PIO), a peroxisome proliferator-activated receptor gamma (PPAR{gamma}) agonist, was administered orally for 85 weeks at 16 mg/kg/day to male rats fed either a diet containing 1.5% ammonium chloride (acid-forming diet) or a control diet to investigate the effects of urinary acidification induced by the acid-forming diet on the tumorigenic potential of PIO in the urinary bladder. The surviving animals at the end of the administration period were followed to the end of the 2-year study period without changes in the diet and were subjected to terminal necropsy on Week 104. The number of urinary microcrystals, evaluated by manual counting with light microscopy and by an objective method with a laser diffraction particle size analyzer, was increased by PIO on Weeks 12 and 25 and the increases were markedly suppressed by urinary acidification. Urinary citrate was decreased by PIO throughout the study period, but no changes were seen in urinary oxalate at any timepoint. The incidences of PIO-treated males bearing at least one of the advanced proliferative changes consisting of papillary hyperplasia, nodular hyperplasia, papilloma or carcinoma were significantly decreased from 11 of 82 males fed the control diet to 2 of 80 males fed the acid-forming diet. The acid-forming diet did not show any effects on the toxicokinetic parameters of PIO and its metabolites. Microcrystalluria appears to be involved in the development of the advanced stage proliferative lesions in bladder tumorigenesis induced by PIO in male rats.

60 APPLIED LIFE SCIENCES↗

Present status of SPring-8 macromolecular crystallography beamlines

Seven beamlines are operated for macromolecular crystallography (MX) at SPring-8. The three undulator beamlines are developed for cutting edge target and four bending-magnet beamlines are developed for high throughput MX. The undulator beamline, BL41XU that provides the most brilliant beam, is dedicated to obtain high quality data even from small-size and weakly-diffracting crystals. The minimum beam size at sample position is achieved to 10 {mu}m diameter using a pin-hole collimator. Its photon flux at wavelength {lambda} = 1.0 A is 2.8x10{sup 11} photons/sec. This small beam coupled with irradiation point scanning method is quite useful to take diffraction dataset from small crystals by suppressing the radiation damage. These advanced technologies made a number of difficult protein structure analysis possible, (i.e. Sodium-potassium ATPase). The bending-magnet beamlines BL26B1/B2 and BL38B1 provide automatic data collection exploiting the high mobility of the beam. The beamline operation software 'BSS', sample auto-changer 'SPACE' and web-based data management software 'D-Cha' have made the automatic data collection possible. The 'Mail-in data collection system' that accepts distant users samples via courier service have made users possible to collect diffraction data without visiting SPring-8. The structural genomics research is promoted by these beamlines.

43 PARTICLE ACCELERATORS↗

Area-selected Ion Milling for Reflection Wavefront Error Correction of Soft X-ray Multilayer Mirrors

For accurate reflection wavefront error correction of imaging soft X-ray multilayer mirrors, a period-by-period ion milling system was developed. A stable and homogenized radial distribution of ion beam was realized for an ion milling over a whole area of 100 mm-wide multilayer. To demonstrate the wavefront error correction principle, a dielectric multilayer mirror for visible light was locally milled by our system. Wavefront as measured by a phase shifting interferometer showed the reflection phase of local milling multilayer advanced. Area-selected ion millings with mask templates made of Mo and Si, and by photoresist contact masks were carried out. Although striped patterns generated by the difference of spectroscopic reflectance between Mo and Si were observed at peripherals of milling area when templates were used, a clear and sharp edge pattern was obtained with contact mask. Soft X-ray reflectance of a Mo/Si multilayer milled with photoresist contact mask showed good feasibility of precise wavefront error correction of multilayers. These results proved our phase correction method is promising and practical for the 0.1 nm-period correction of soft X-ray multilayer mirror.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improvement in Stability of SPring-8 Standard X-Ray Monochromators with Water-Cooled Crystals

SPring-8 standard double-crystal monochromators containing water-cooled crystals were stabilized to a sufficient level to function as a part of optics components to supply stable microfocused x-ray beams, by determining causes of the instability and then removing them. The instability was caused by two factors--thermal deformation of fine stepper stages in the monochromator, which resulted in reduction in beam intensity with time, and vibrations of coolant supply units and vacuum pumps, which resulted in fluctuation in beam intensity. We remodeled the crystal holders to maintain the stage temperatures constant with water, attached x-ray and electron shields to the stages in order to prevent their warming up, introduced accumulators in the water circuits to absorb pressure pulsation, used polyurethane tubes to stabilize water flow, and placed rubber cushions under scroll vacuum pumps. As a result, the intensity reduction rate of the beam decreased from 26% to 1% per hour and the intensity fluctuation from 13% to 1%. The monochromators were also modified to prevent radiation damage to the crystals, materials used as a water seal, and motor cables.

43 PARTICLE ACCELERATORS↗

Two-dimensional Detector for High Resolution Soft X-ray Imaging

A new two-dimensional (2D) detector for detecting soft X-ray (SX) images was developed. The detector has a scintillator plate to convert a SX image into a visible (VI) one, and a relay optics to magnify and detect the converted VI image. In advance of the fabrication of the detector, quantum efficiencies of scintillators were investigated. As a result, a Ce:LYSO single crystal on which Zr thin film was deposited was used as an image conversion plate. The spatial resolution of fabricated detector is 3.0 {mu}m, and the wavelength range which the detector has sensitivity is 30-6 nm region.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New micro-beam beamline at SPring-8, targeting at protein micro-crystallography

A new protein micro-crystallography beamline BL32XU at SPring-8 is under construction and scheduled to start operation in 2010. The beamline is designed to provide the stabilized and brilliant micro-beam to collect high-quality data from micro-crystals. The beamline consists of a hybrid in-vacuum undulator, a liquid-nitrogen cooled double crystal monochromator, and K-B focusing mirrors with large magnification factor. Development of data acquisition system and end station consists of high-precision diffractometer, high-efficiency area detector, sample auto-changer etc. are also in progress.

43 PARTICLE ACCELERATORS↗

Layer-by-layer design method for soft-X-ray multilayers

A new design method effective for a nontransparent system has been developed for soft-X-ray multilayers with the aid of graphic representation of the complex amplitude reflectance in a Gaussian plane. The method provides an effective means of attaining the absolute maximum reflectance on a layer-by-layer basis and also gives clear insight into the evolution of the amplitude reflectance on a multilayer as it builds up. An optical criterion is derived for the selection of a proper pair of materials needed for designing a high-reflectance multilayer. Some examples are given to illustrate the usefulness of this design method.

Yamamoto, Masaki↗