Laboratory Study of Magnetic Reconnection with a Density Asymmetry across the Current Sheet
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Yamada, M.
Explore the source record for details and available documents.
Purpose: The Vero4DRT has a maximum field size of 150×150 mm{sup 2}. The purposes of this study were to develop an expanded field irradiation technique using a unique gimbaled x-ray head of Vero4DRT and to evaluate its dosimetric characteristic. Methods: The expanded field irradiation consisted of four separate fields with 2.39 degree gimbal rotation around orthogonal two axes. The central beam axis for each field shifted 40 mm from the isocenter for longitudinal and lateral directions, and thus, the field size was expanded up to 230×230 mm{sup 2}. Adjacent region were created at the isocenter (center-adjacent expanded-field) and 20 mm from isocenter (offadjacent expanded-field). To create flat dose distribution in the combined piecewise-fields, the overlapping and gaps regions on the isocenter plane were adjusted with the gimbal rotating and the MLC. To evaluate dosimetric characteristic of the expanded-field, films inserted in water-equivalent phantoms at 50, 100 and 150 mm depth were irradiated and the field size, penumbra, flatness and symmetry were analyzed.In addition, the expandedfield irradiation technique was applied to IMRT. A head and neck IMRT field, which was planned for the conventional linac (Varian Clinac iX), was reproduced with the expanded-field of the Vero4DRT. The simulated dose distribution for the expanded IMRT field was compared to the measured dose distribution. Results: The field size, penumbra, flatness and symmetry of center- and off- adjacent expanded-fields were 230.2–232.1 mm, 7.8–10.7 mm, 2.3–6.5% and –0.5–0.4% at 100 mm depth. The 82.1% area of the expanded IMRT dose distribution was within 5% difference between measurement and simulation, which was analyzed upper 50% dose area, and the 3%/3 mm gamma pass rate was 98.4%. Conclusions: The expandedfield technique was developed using the gimbaled x-ray head. To extend applied targets, such as whole breast irradiations or head and neck IMRT, the expanded-field technique would be effective.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The stability properties of partial-toroidal flux ropes are studied in detail in the laboratory, motivated by ubiquitous arched magnetic structures found on the solar surface. The flux ropes studied here are magnetized arc discharges formed between two electrodes in the Magnetic Reconnection Experiment (MRX) [Yamada et al., Phys. Plasmas 4, 1936 (1997)]. The three dimensional evolution of these flux ropes is monitored by a fast visible light framing camera, while their magnetic structure is measured by a variety of internal magnetic probes. The flux ropes are consistently observed to undergo large-scale oscillations as a result of an external kink instability. Using detailed scans of the plasma current, the guide field strength, and the length of the flux rope, we show that the threshold for kink stability is governed by the Kruskal-Shafranov limit for a flux rope that is held fixed at both ends (i.e., q{sub a} = 1).
Explore the source record for details and available documents.
We have developed a prototype rotating-permanent magnet sextupole lens (named rot-PMSx) for more efficient experiments with neutron beams in time of flight (ToF) mode. This lens can modulate the focusing strength over range 1.5 x 10{sup 4} T/m{sup 2} {le} g' {le} 5.9 x 10{sup 4} T/m{sup 2}. Synchronization between the modulation and the beam pulse produces a focused beam without significant chromatic aberration. We anticipate that this lens could be utilized in focusing small angle neutron scattering (SANS) instruments for novel approach to high resolution SANS. We carried out experiments testing the principle of this lens at the very cold neutron (VCN) beamline (PF2) at Institut Laue-Langevin (ILL), France. The focused beam image size at the detector was kept constant at the same beam size as the source ({approx} 3 mm) over a wavelength range of 30 {angstrom} {le} {lambda} {le} 48 {angstrom} in focal length of {approx} 1.14 m. The flux gain was about 12 relative to a beam without focusing, and the depth of focus was quite large. These results show the good performance of this lens and the system. Thereupon we have demonstrated the performance of this test bed for high resolution focusing of VCN-SANS for a well-studied softmatter sample; a deuterium oxide solution of Pluronic F127, an (PEO){sub 100}(PPO){sub 65}(PEO){sub 100} tri-block copolymer in deuterium oxide. The results of the focusing experiment and the focusing VCN-SANS are presented.
The influence of Coulomb collisions on the dynamics of driven magnetic reconnection in geometry mimicking the Magnetic Reconnection eXperiment (MRX) [M. Yamada et al., Phys. Plasmas 4, 1936 (1997)] is investigated using two-dimensional (2D) fully kinetic simulations with a Monte Carlo treatment of the collision operator. For values of collisionality typical of MRX, the reconnection mechanism is shown to be a combination of collisionless effects, represented by off-diagonal terms in the electron stress tensor, and collisional momentum exchange between electrons and ions. The ratio of the reconnection electric field E{sub R} to the critical runaway field E{sub crit} provides a convenient measure of the relative importance of these two mechanisms. The structure of electron-scale reconnection layers in the presence of collisions is investigated in light of the previously reported [S. Dorfman et al., Phys. Plasmas 15, 102107 (2008)] discrepancy in the width of the electron reconnection layers between collisionless simulations and experimental observations. It is demonstrated that the width of the layer increases in the presence of collisions, but does not substantially deviate from its collisionless values, given by the electron crossing orbit width, unless E{sub R}<<E{sub crit}. Comparison with MRX observations demonstrates that the layer width in 2D simulations with Coulomb collisions is substantially smaller than the value observed in the low-density experiments with E{sub R} < or approx. E{sub crit}, indicating that physical mechanisms beyond those included in the simulations control the structure of the electron layers in these experiments.
Explore the source record for details and available documents.
No abstract prepared.
Two-dimensional fully kinetic simulations are performed using global boundary conditions relevant to model the Magnetic Reconnection Experiment (MRX) [M. Yamada et al., Phys Plasmas 4, 1936 (1997)]. The geometry is scaled in terms of the ion kinetic scales in the experiment, and a reconnection layer is created by reducing the toroidal current in the flux cores in a manner similar to the actual experiment. The ion-scale features in these kinetic simulations are in remarkable agreement with those observed in MRX, including the reconnection inflow rate and quadrupole field structure. In contrast, there are significant discrepancies in the simulated structure of the electron layer that remain unexplained. In particular, the measured thickness of the electron layers is 3-5 times thicker in MRX than in the kinetic simulations. The layer length is highly sensitive to downstream boundary conditions as well as the time over which the simulation is driven. However, for a fixed set of chosen boundary conditions, an extrapolation of the scaling with the ion to electron mass ratio implies that at realistic mass ratio both the length and width will be too small compared to the experiment. This discrepancy implies that the basic electron layer physics may differ significantly between MRX and the two-dimensional, collisionless simulations. The two leading possibilities to explain the discrepancy are weak Coulomb collisions and three-dimensional effects that are present in the experiment but not included in the simulation model.
We report the first identification of the electron-diffusion region, where demagnetized electrons are accelerated to super-Alfvenic speed, in a reconnecting laboratory plasma. The width of the electron-diffusion region scales with the electron skin depth [{approx}(5.5-7.5)c/{omega}{sub pe}] and the peak electron outflow velocity scales with the electron Alfven velocity [{approx}(0.12-0.16)V{sub eA}], independent of ion mass.
Explore the source record for details and available documents.
A new field-reversed configuration (FRC) formation technique is described, where a spheromak transitions to a FRC with inductive current drive. The transition is accomplished only in argon and krypton plasmas, where low-n kink modes are suppressed; spheromaks with a lighter majority species, such as neon and helium, either display a terminal tilt-mode, or an n=2 kink instability, both resulting in discharge termination. The stability of argon and krypton plasmas through the transition is attributed to the rapid magnetic diffusion of the currents that drive the kink-instability. The decay of helicity during the transition is consistent with that expected from resistivity. This observation indicates a new scheme to form a FRC plasma, provided stability to low-n modes is maintained, as well as a unique situation where the FRC is a preferred state.