Experiments on HOM Spectrum Manipulation in a 1.3 GHz ILC SC Cavity
Abstract Not Provided
Engineering topics
Publications and source records attributed to Yakovlev, V P.
Abstract Not Provided
Abstract Not Provided
No abstract prepared.
A preliminary design and current status are presented for a two-cavity 7th harmonic multiplier, intended as a high-power RF source for use in experiments aimed at developing high-gradient structures for a future collider. The harmonic multiplier is to produce power in K-band using as its RF driver an XK-5 S-band klystron (2.856 GHz). The multiplier is to be built with a TE{sub 111} rotating mode input cavity and interchangeable output cavities, a principal example being a TE{sub 711} rotating mode cavity running at 20 GHz. The design that is described uses a 250 kV, 20 A injected laminar electron beam. With 8.5 MW of S-band drive power, 4.4 MW of 20-GHz output power is predicted. The design uses a gun, magnetic coils, and beam collector from an existing waveguide 7th harmonic multiplier. The gun has been re-conditioned and the desired operating parameters have been achieved.
Conceptual design of a multi-beam klystron (MBK) for possible ILC and Project X applications is presented. The chief distinction between this MBK design and existing 10-MW MBK's is the low operating voltage of 60 kV. There are at least four compelling reasons that justify development at this time of a low-voltage MBK, namely (1) no pulse transformer; (2) no oil tank for high-voltage components and for the tube socket; (3) no high-voltage cables; and (4) modulator would be a compact 60-kV IGBT switching circuit. The proposed klystron consists of four clusters containing six beams each. The tube has common input and output cavities for all 24 beams, and individual gain cavities for each cluster. A closely related optional configuration, also for a 10 MW tube, would involve four totally independent cavity clusters with four independent input cavities and four 2.5 MW output ports, all within a common magnetic circuit. This option has appeal because the output waveguides would not require a controlled atmosphere, and because it would be easier to achieve phase and amplitude stability as required in individual SC accelerator cavities.
A two-beam accelerator structure is described having several novel features including all metal construction, no transfer structures required between the drive and accelerator channels, symmetric fields at the axes of each channel, RF micropulse widths on cavity irises that are less than half those for a conventional cavity at the same fundamental frequency by virtue of using several harmonically-related cavity modes, and a transformer ratio much greater than unity by the use of detuned cavities. Detuning is also shown to allow either parallel or anti-parallel directions for the drive and accelerated beams. A preliminary calculation for the dilution of emittance due to short-range wakes for drive beam parameters similar to those for CLIC shows this effect to be acceptably small.
The most severe problem of the International Linear Collider is its high cost, resulting in part from the enormous length of the collider. This length is determined mainly by the achievable accelerating gradient in the RF system of the ILC. In the ILC project the required accelerating gradient is higher than 30 MeV/m. Further improvement of the coupling to the beam may be achieved by using a Traveling Wave SC structure [1]. We have demonstrated that an additional gradient increase of up to 46% may be possible if a {pi}/2 TW SC structure is employed. However, a TW SC structure requires a SC feedback waveguide to return the few GW of circulating RF power from the structure output back to the structure input. The test cavity with feedback is designed to demonstrate the possibility of achieving a significantly higher gradient than existing SC structures. The double-coupler powering excitation and tuning have been studied numerically and the corresponding model results are presented. The proposed double-coupler powering scheme significantly reduces the tuning requirements as long as any of the partial modes of given magnitude and phase are excited independently, providing a clear traveling wave regime of structure operation.
A preliminary design is presented for a two-cavity harmonic multiplier, intended as a high-power RF source for use in experiments aimed at developing high-gradient structures for a future collider. The harmonic multiplier is to produce power at selected frequencies in K-band (18-26.5 GHz) using as an RF driver an XK-5 S-band klystron (2.856 GHz). The device is to be built with a TE{sub 111} rotating mode input cavity and interchangeable output cavities running in the TE{sub n11} rotating mode, with n = 7,8,9 at 19.992, 22.848, and 25.704 GHz. An example for a 7{sup th} harmonic multiplier is described, using a 250 kV, 20 A injected laminar electron beam; with 10 MW of S-band drive power, 4.7 MW of 20-GHz output power is predicted. Details are described of the magnetic circuit, cavities, and output coupler.