Engineering topics
Xu, Y.
Publications and source records attributed to Xu, Y..
Formation and stability of dense arrays of Au nanoclusters on hexagonal boron nitride/Rh(111)
Explore the source record for details and available documents.
Long-term stability of the Leksell Gamma Knife{sup ®} Perfexion™ patient positioning system (PPS)
Purpose: To assess the long-term mechanical stability and accuracy of the patient positioning system (PPS) of the Leksell Gamma Knife{sup ®} Perfexion™ (LGK PFX). Methods: The mechanical stability of the PPS of the LGK PFX was evaluated using measurements obtained between September 2007 and June 2011. Three methods were employed to measure the deviation of the coincidence of the radiological focus point (RFP) and the PPS calibration center point (CCP). In the first method, the onsite diode test tool with single diode detector was used together with the 4 mm collimator on a daily basis. In the second method, a service diode test tool with three diode detectors was used biannually at the time of the routine preventive maintenance. The test performed with the service diode test tool measured the deviations for all three collimators 4, 8, and 16 mm and also for three different positions of the PPS. The third method employed the conventional film pin-prick method. This test was performed annually for the 4 mm collimator at the time of the routine annual QA. To estimate the effect of the patient weight on the performance of the PPS, the focus precision tests were also conducted with varying weights on the PPS using a set of lead bricks. Results: The average deviations measured from the 641 daily focus precision tests were 0.1 ± 0.1, 0.0 ± 0.0, and 0.0 ± 0.0 mm, respectively, for the 4 mm collimator in the X (left/right of the patient), Y (anterior/posterior of the patient), and Z (superior/inferior of the patient) directions. The average of the total radial deviations as measured during ten semiannual measurements with the service diode test tool were 0.070 ± 0.029, 0.060 ± 0.022, and 0.103 ± 0.028 mm, respectively for the central, long, and short diodes for the 4 mm collimator. Similarly, the average total radial deviations measured during the semiannual measurements for the 4, 8, and 16 mm collimators and using the central diode were 0.070 ± 0.029, 0.097 ± 0.025, 0.159 ± 0.028 mm, respectively. The average values of the deviations as obtained from the five annual film pin-prick tests for the 4 mm collimator were 0.10 ± 0.06, 0.06 ± 0.09, and 0.03 ± 0.03 mm for the X, Y, Z stereotactic directions, respectively. Only a minor change was observed in the total radial deviations of the PPS as a function of the simulated patient weight up to 202 kg on the PPS. Conclusions: Excellent long-term mechanical stability and high accuracy was observed for the PPS of the LGK PFX. No PPS recalibration or any adjustment in the PPS was needed during the monitored period of time. Similarly, the weight on the PPS did not cause any significant disturbance in the performance of the PPS for up to 202 kg simulated patient weight.
Trigonometric parallaxes of high mass star forming regions: the structure and kinematics of the Milky Way
Over 100 trigonometric parallaxes and proper motions for masers associated with young, high-mass stars have been measured with the Bar and Spiral Structure Legacy Survey, a Very Long Baseline Array key science project, the European VLBI Network, and the Japanese VLBI Exploration of Radio Astrometry project. These measurements provide strong evidence for the existence of spiral arms in the Milky Way, accurately locating many arm segments and yielding spiral pitch angles ranging from about 7° to 20°. The widths of spiral arms increase with distance from the Galactic center. Fitting axially symmetric models of the Milky Way with the three-dimensional position and velocity information and conservative priors for the solar and average source peculiar motions, we estimate the distance to the Galactic center, R {sub 0}, to be 8.34 ± 0.16 kpc, a circular rotation speed at the Sun, Θ{sub 0}, to be 240 ± 8 km s{sup –1}, and a rotation curve that is nearly flat (i.e., a slope of –0.2 ± 0.4 km s{sup –1} kpc{sup –1}) between Galactocentric radii of ≈5 and 16 kpc. Assuming a 'universal' spiral galaxy form for the rotation curve, we estimate the thin disk scale length to be 2.44 ± 0.16 kpc. With this large data set, the parameters R {sub 0} and Θ{sub 0} are no longer highly correlated and are relatively insensitive to different forms of the rotation curve. If one adopts a theoretically motivated prior that high-mass star forming regions are in nearly circular Galactic orbits, we estimate a global solar motion component in the direction of Galactic rotation, V {sub ☉} = 14.6 ± 5.0 km s{sup –1}. While Θ{sub 0} and V {sub ☉} are significantly correlated, the sum of these parameters is well constrained, Θ{sub 0} + V {sub ☉} = 255.2 ± 5.1 km s{sup –1}, as is the angular speed of the Sun in its orbit about the Galactic center, (Θ{sub 0} + V {sub ☉})/R {sub 0} = 30.57 ± 0.43 km s{sup –1} kpc{sup –1}. These parameters improve the accuracy of estimates of the accelerations of the Sun and the Hulse-Taylor binary pulsar in their Galactic orbits, significantly reducing the uncertainty in tests of gravitational radiation predicted by general relativity.
Plasma studies of the permanent magnet electron cyclotron resonance ion source at Peking University
At Peking University (PKU) we have developed several 2.45 GHz Permanent Magnet Electron Cyclotron Resonance ion sources for PKUNIFTY, SFRFQ, Coupled RFQ and SFRFQ, and Dielectric-Wall Accelerator (DWA) projects (respectively, 50 mA of D{sup +}, 10 mA of O{sup +}, 10 mA of He{sup +}, and 50 mA of H{sup +}). In order to improve performance of these ion sources, it is necessary to better understand the principal factors that influence the plasma density and the atomic ion fraction. Theoretical analysis about microwave transmission and cut-off inside the discharge chamber were carried out to study the influence of the discharge chamber diameters. As a consequence, experimental studies on plasma density and ion fraction with different discharge chamber sizes have been carried out. Due to the difficulties in measuring plasma density inside the discharge chamber, the output beam current was measured to reflect the plasma density. Experimental results show that the plasma density increases to the maximum and then decreases significantly as the diameter changed from 64 mm to 30 mm, and the atomic ion fraction has the same tendency. The maximum beam intensity was obtained with the diameter of 35 mm, but the maximum atomic ion fraction with a diameter of 40 mm. The experimental results are basically accordant with the theoretical calculation. Details are presented in this paper.
Handling radiation generated during an ion source commissioning
Radiation is an important issue, which should be carefully treated during the design and commissioning of an ion source. Measurements show that X-rays are generated around the ceramics column of an extraction system when the source is powered up to 30 kV. The X-ray dose increases greatly when a beam is extracted. Inserting the ceramic column into a metal vacuum box is a good way to block X-ray emission for those cases. Moreover, this makes the online test of an intense H{sup +} ion beam with energy up to 100 keV possible. However, for deuteron ion source commissioning, neutron and gamma-ray radiation become a serious topic. In this paper, we will describe the design of the extraction system and the radiation doses of neutrons and gamma-rays measured at different D{sup +} beam energy during our 2.45 GHz deuteron electron cyclotron resonance ion source commissioning for PKUNIFTY (PeKing University Neutron Imaging FaciliTY) project at Peking University.
Surface smoothing effect of an amorphous thin film deposited by atomic layer deposition on a surface with nano-sized roughness
Previously, Lau (one of the authors) pointed out that the deposition of an amorphous thin film by atomic layer deposition (ALD) on a substrate with nano-sized roughness probably has a surface smoothing effect. In this letter, polycrystalline zinc oxide deposited by ALD onto a smooth substrate was used as a substrate with nano-sized roughness. Atomic force microscopy (AFM) and cross-sectional transmission electron microscopy (XTEM) were used to demonstrate that an amorphous aluminum oxide thin film deposited by ALD can reduce the surface roughness of a polycrystalline zinc oxide coated substrate.
The parallax of W43: A massive star-forming complex near the galactic bar
We report trigonometric parallax measurements of masers in the massive star-forming complex W43 from Very Long Baseline Array observations as part of the Bar and Spiral Structure Legacy Survey. Based on measurements of three 12 GHz methanol maser sources (G029.86–00.04, G029.95–00.01, and G031.28+00.06) and one 22 GHz water maser source (G031.58+00.07) toward W43, we derived a distance of 5.49{sub −0.34}{sup +0.39} kpc to W43. By associating the masers with CO molecular clouds, and associating the clouds kinematically with CO longitude-velocity spiral features, we assign W43 to the Scutum spiral arm, close to the near end of the Galactic bar. The peculiar motion of W43 is about 20 km s{sup –1} toward the Galactic Center and is very likely induced by the gravitational attraction of the bar.
Atomic state and characterization of nitrogen at the SiC/SiO{sub 2} interface
We report on the concentration, chemical bonding, and etching behavior of N at the SiC(0001)/SiO{sub 2} interface using photoemission, ion scattering, and computational modeling. For standard NO processing of a SiC MOSFET, a sub-monolayer of nitrogen is found in a thin inter-layer between the substrate and the gate oxide (SiO{sub 2}). Photoemission shows one main nitrogen related core-level peak with two broad, higher energy satellites. Comparison to theory indicates that the main peak is assigned to nitrogen bound with three silicon neighbors, with second nearest neighbors including carbon, nitrogen, and oxygen atoms. Surprisingly, N remains at the surface after the oxide was completely etched by a buffered HF solution. This is in striking contrast to the behavior of Si(100) undergoing the same etching process. We conclude that N is bound directly to the substrate SiC, or incorporated within the first layers of SiC, as opposed to bonding within the oxide network. These observations provide insights into the chemistry and function of N as an interface passivating additive in SiC MOSFETs.
Mechanistic insights into the role of Hop2-Mnd1 in meiotic homologous DNA pairing
The Hop2–Mnd1 complex functions with the DMC1 recombinase in meiotic recombination. Hop2–Mnd1 stabilizes the DMC1-single-stranded DNA (ssDNA) filament and promotes the capture of the double stranded DNA partner by the recombinase filament to assemble the synaptic complex. Herein, we define the action mechanism of Hop2–Mnd1 in DMC1-mediated recombination. Small angle X-ray scattering analysis and electron microscopy reveal that the heterodimeric Hop2–Mnd1 is a V-shaped molecule. We show that the protein complex harbors three distinct DNA binding sites, and determine their functional relevance. Specifically, the N-terminal double-stranded DNA binding functions of Hop2 and Mnd1 co-operate to mediate synaptic complex assembly, whereas ssDNA binding by the Hop2 C-terminus helps stabilize the DMC1-ssDNA filament. A model of the Hop2-Mnd1-DMC1-ssDNA ensemble is proposed to explain how it mediates homologous DNA pairing in meiotic recombination.
Inter- and intra-specific pan-genomes of Borrelia burgdorferi sensu lato: genome stability and adaptive radiation
N/A
PARALLAXES FOR W49N AND G048.60+0.02: DISTANT STAR FORMING REGIONS IN THE PERSEUS SPIRAL ARM
We report trigonometric parallax measurements of 22 GHz H{sub 2}O masers in two massive star-forming regions from Very Long Baseline Array observations as part of the Bar and Spiral Structure Legacy Survey. The distances of 11.11{sup +0.79}{sub -0.69} kpc to W49N (G043.16+0.01) and 10.75{sup +0.61}{sub -0.55} kpc to G048.60+0.02 locate them in a distant section of the Perseus arm near the solar circle in the first Galactic quadrant. This allows us to locate accurately the inner portion of the Perseus arm for the first time. Combining the present results with sources measured in the outer portion of the arm in the second and third quadrants yields a global pitch angle of 9.°5 ± 1.°3 for the Perseus arm. We have found almost no H{sub 2}O maser sources in the Perseus arm for 50° <l < 80°, suggesting that this ≈6 kpc section of the arm has little massive star formation activity.
Critical node treatment in the analytic function expansion method for Pin Power Reconstruction
Pin Power Reconstruction (PPR) was implemented in PARCS using the eight term analytic function expansion method (AFEN). This method has been demonstrated to be both accurate and efficient. However, similar to all the methods involving analytic functions, such as the analytic node method (ANM) and AFEN for nodal solution, the use of AFEN for PPR also has potential numerical issue with critical nodes. The conventional analytic functions are trigonometric or hyperbolic sine or cosine functions with an angular frequency proportional to buckling. For a critic al node the buckling is zero and the sine functions becomes zero, and the cosine function become unity. In this case, the eight terms of the analytic functions are no longer distinguishable from ea ch other which makes their corresponding coefficients can no longer be determined uniquely. The mode flux distribution of critical node can be linear while the conventional analytic functions can only express a uniform distribution. If there is critical or near critical node in a plane, the reconstructed pin power distribution is often be shown negative or very large values using the conventional method. In this paper, we propose a new method to avoid the numerical problem wit h critical nodes which uses modified trigonometric or hyperbolic sine functions which are the ratio of trigonometric or hyperbolic sine and its angular frequency. If there are no critical or near critical nodes present, the new pin power reconstruction method with modified analytic functions are equivalent to the conventional analytic functions. The new method is demonstrated using the L336C5 benchmark problem. (authors)
Carbon-11 radiolabeling of iron-oxide nanoparticles for dual-modality PET/MRI imaging
N/A
Effects of nanosecond-scale prepulse on generation of high-energy protons in target normal sheath acceleration
A pulse cleaner based on noncollinear optical-parametric amplification and second-harmonic generation processes is used to improve the contrast of a laser of peak intensity {approx}2 Multiplication-Sign 10{sup 19} W/cm{sup 2} to {approx}10{sup 11} at 100 ps before the peak of the main pulse. A 7 MeV proton beam is observed when a 2.5 {mu}m-thick Al foil is irradiated by this high-contrast laser. The maximum proton energy decreases to 2.9 MeV when a low-contrast ({approx}10{sup 8}) laser is used. Two-dimensional particle-in-cell simulations combined with MULTI simulations show that the maximum proton energy sensitively relies on the detecting direction. The ns-time-scale prepulse can bend a thin target before the main pulse arrives, which reduces maximum proton energy in the target normal sheath acceleration.
ON THE NATURE OF THE LOCAL SPIRAL ARM OF THE MILKY WAY
Trigonometric parallax measurements of nine water masers associated with the Local Arm of the Milky Way were carried out as part of the BeSSeL Survey using the Very Long Baseline Array. When combined with 21 other parallax measurements from the literature, the data allow us to study the distribution and three-dimensional motions of star forming regions in the spiral arm over the entire northern sky. Our results suggest that the Local Arm does not have the large pitch angle characteristic of a short spur. Instead its active star formation, overall length (>5 kpc), and shallow pitch angle ({approx}10 Degree-Sign ) suggest that it is more like the adjacent Perseus and Sagittarius Arms; perhaps it is a branch of one of these arms. Contrary to previous results, we find the Local Arm to be closer to the Perseus than to the Sagittarius Arm, suggesting that a branching from the former may be more likely. An average peculiar motion of near zero toward both the Galactic center and north Galactic pole, and counter rotation of {approx}5 km s{sup -1} were observed, indicating that the Local Arm has similar kinematic properties as found for other major spiral arms.
Development of the gas-puff imaging diagnostic in the TEXTOR tokamak
Gas puff imaging (GPI) [S. J. Zweben, D. P. Stotler et al., Phys. Plasmas 9, 1981 (2002); R. J. Maqueda, G. A. Wurden et al., Rev. Sci. Instrum. 74, 2020 (2003)] is a powerful diagnostic that permits a two-dimensional measurement of turbulence in the edge region of a fusion plasma and is based on the observation of the local emission of a neutral gas, actively puffed into the periphery of the plasma. The developed in-vessel GPI telescope observes the emission from the puffed gas along local (at the puff) magnetic field lines. The GPI telescope is specially designed to operate in severe TEXTOR conditions and can be treated as a prototype for the GPI systems on next generation machines. Also, the gas puff nozzle is designed to have a lower divergence of the gas flow than previous GPI diagnostics. The resulting images show poloidally and radially propagating structures, which are associated with plasma blobs. We demonstrate that the local gas puff does not disturb plasma properties. Our results indicate also that the neutral gas emission intensity is more sensitive to the electron density than the electron temperature. Here, we present implementation details of the GPI system on TEXTOR and discuss some design and diagnostic issues related to the development of GPI systems in general.