Engineering Papers⌕ Search

Engineering topics

Wu, Yongji

Publications and source records attributed to Wu, Yongji.

Test and Validate Distributed Coaxial Cable Sensors for in situ Condition Monitoring of Coal-Fired Boiler Tubes

This project aims to test, validate, and advance the technology readiness level (from TRL5 to TRL7) of a novel low-cost distributed stainless-steel/ceramic coaxial cable sensing (SSC-CCS) technology for in situ monitoring of the boiler tube temperature in existing coal-fired power plants. The novel SSC-CCS sensing technology and associated condition-based monitoring (CBM) software to be demonstrated in this project will lead to an improved understanding of the boiler tube failure mechanisms and a prognostic system to improve the overall performance, reliability, and flexibility of the nation’s coal-fired power plant fleet. A boiler tube monitoring system with distributed coaxial cable temperature sensors and a sensor acquisition system was constructed. The high-temperature coaxial cable sensor with a length of 1.3m was made by using a quartz tube (1mm inner diameter (ID) and 6mm outer diameter (OD)) to concentrically separate a 304 stainless-steel (SS) rod (1mm OD) and SS tube (7.94mm OD and 6.16mm ID). The sensor acquisition system includes a vector network analyzer (VNA), a radio frequency (RF) power amplifier, multiple switches and a USB hub. The distributed stainless-steel quartz coaxial cable sensor (SSQ-CCS) had a linear response to temperature with a resolution uncertainty of σ = 0.77℃. To withstand the harsh conditions of 3,300 steam pressures and 800℃ high temperatures, the sensor was shielded by a protective tube made of the same material as the boiler tube. The protection tube had an OD of 1.5 inches and a thickness of 0.25 inches. In the laboratory tests, the sensor showed good sensitivity and fast response. The drift was bounded between +0.33% and -0.67% during a test at 600℃ for 350 hours, indicating good stability of the sensor. A field test was conducted where four sensors were welded on four superheat tubes (SH-Ts) at a coal-fired power station over 400 days. Conventional thermocouples were welded to the superheater tubes alongside the coaxial cable sensors for the purpose of comparison. Two sensors were capable of distributed sensing, with three multiplexed sensing sections. The other two sensors were single section. During the 400-day test period, the power plant experienced startups and shutdowns. At the steady state operations, the temperature of the boiler tube is about 600℃ (1112°F). The sensors recorded the entire coal-firing processes (start-up, steady state, and shut-down) and the glitch event. A GSM modem and a Watchdog were added to the system to ensure reliable data recording. The GSM modem sent daily messages to plant managers and Clemson team to inform the status of the sensor system. If the system was not normally working, the Watchdog would reboot the system automatically. The new coaxial cable based distributed sensing technology has been proven to be successful in both laboratory and field tests. A comprehensive four-stage multi-physics computational framework has been developed to assist the design, optimization, installation, and operation of SSQ-CCS. With the consideration of various operation conditions, we predict the distributions of flue gas temperatures within coal-fired boilers, the temperature correlation between the boiler tube and SSQ-CCS, and the safety of SSQ-CCS. A conditional-based monitoring system is implemented as well. The computational framework developed in this work can guide the future operation of coal-fired plants and other power plants for the safety prediction of boiler operations.

01 COAL, LIGNITE, AND PEAT↗

Fabrication and Testing of a Stainless Steel Quartz Coaxial Cable Structure for High Temperature Measurement

This paper presents a stainless-steel quartz coaxial cable structure for distributed sensing of high temperatures. The coaxial cable sensor uses stainless steel as the inner and outer conductors and quartz as the insulator in order to achieve mechanical strength and temperature resilience. Girdle-shaped reflectors are fabricated on the quartz tubing by CNC grinding and CO 2 laser resurfacing. The sensor operates by measuring the temperature dependent change in the effective electromagnetic length between the two adjacent reflectors on the quartz tubing. A retaining collar is fabricated at the tip of the quartz tubing by 3D printing and laser resurfacing to secure the connection between the sensor and the signal cable. The prototype sensor was tested for high temperature measurements up to 600°C, and the performance characteristics of the sensor such as sensitivity, resolution uncertainty, repeatability, and stability were estimated based on the test results.

Jiao, Xinyu↗

All-digital Sensor System for Distributed Downhole Pressure Monitoring in Unconventional Fields

This project developed and validated (through field tests) a new low-cost all-digital pressure sensing technology for in situ distributed downhole pressure monitoring in unconventional oil and gas (UOG) fields. The all-digital sensing technology uses a built-in non-electric analog-to-digital converter (ADC) to transform the pressure information into a combination of binary (ON/OFF) states. As such, the system does not need downhole electronics for signal conditioning and telemetry. The all-digital sensors can be remotely logged over a long distance, and many sensors can be multiplexed for distributed sensing. Based on a review of unconventional wells in the Lower 48 states, the specification of the sensor is to measure pressure up to 69 MPa (10,000 psi) and temperature up to 250°C. A sensor with a helical bourdon sensing element and a digital signal decoder of 50 mm diameter and 109 mm length was constructed. The helical bourdon sensing element was made of 304L stainless steel and filled with motor oil. The digital converter was made up of 8 digital reading pads constructed of high-temperature epoxy with conductive inserts made of stainless steel. The sensor had a linear response to pressure with an accuracy of 0.14 MPa (20 psi). To withstand the high pressure, the sensor was enclosed in a stainless-steel pressure housing with a wall thickness of 5.5 mm, a diameter of 73 mm, and a length of 724 mm. In the laboratory tests, the sensor exhibited no temperature-related effects on the results. The sensor did not show drift over a 14-day test period at elevated pressure. A field test was conducted where the sensor was deployed in a test wellbore at the Quest drilling test facility to a depth of 0 feet over three weeks. The sensor was attached to the production rods, along with a downhole reference sensor of PPS27 type, which is a permanent downhole monitoring system. During the testing phase, the test well annular blow-out preventer was closed, and the well was pressurized at the surface to 11 MPa (1600 psi). The sensor read the elevated bottom hole pressure of 1500 psi. A multiplexing unit was created for the sensor to deploy multiple sensors on one data transmission line in a distributed approach. The multiplexing unit was tested in a simulated environment of 3048 m (10,000 ft) with five sensors distributed. The sensors were pressurized at different intervals. The multiplexed sensors recorded the correct pressure, and the multiplexing did not interfere with the readings. The proposed concept of an all-digital pressure sensor for harsh downhole environments was designed, manufactured, and tested in the laboratory and tested at the field to a up to 69 MPa and 250°C. This technology has high-temperature tolerance and has potential in downhole areas outside oil and gas, such as carbon capture and storage (CCS) and geothermal wells. The sensor concept has been proven in this project, but to create a commercially viable product, manufacturing a sensor with a smaller diameter needs to be performed.

02 PETROLEUM↗

Conductive Spray Paint Fabricated Cylindrical Coplanar Waveguide for Noncontact Liquid-Level Sensing

A noncontact liquid-level sensor using a cylindrical coplanar waveguide (CCPW) is proposed. The concept is demonstrated using a prototype device made by directly spraying conductive paint on the outer surface of a glass cylinder. The position of the air–liquid interface is measured using the time-domain reflection (TDR) signal from the CCPW. The geometric parameters of the prototype sensor were optimized using a full-wave simulation tool. The experimental results show that the prototype CCPW-based liquid-level sensor has a resolution of 29.8μm over a range of 210 mm at the sweeping frequency bandwidth of 500 MHz–4 GHz. The tradeoff between the resolution and the measurement range was discussed. The proposed sensor provides a low-cost, easy-to-fabricate, and noncontact method for liquid-level measurement, which has potential applications in fuel storage, chemical production, and wastewater treatment.

42 ENGINEERING↗

A Microwave Photonics Optical Fiber Method for Measuring Distributed Strain for Hydrologic Applications in the Vadose and Saturated Zones

Distributed strain measurements appear to hold significant potential for monitoring hydrologic processes. Coherence-length-gated Microwave Photonics Interferometry (CMPI) is a distributed sensing technique that measures strain in an optical fiber by reading optical interference phase changes in the microwave domain. The technique provides 10nε resolution when cm spatial resolution is applied. CMPI was used to measure the strain caused by small periodic variations in air pressure (25 Pa amplitude and 4 Hz) in a sand-filled laboratory column used to represent barometric loading in the vadose zone. The strain varied as a periodic function with an amplitude that decreased and a phase that increased with depth. The distribution of amplitude and phase of the strain depended on the water saturation, permeability, and presence of a barrier at the top of the sand. A theoretical analysis suggests that the air pressure diffusivity estimated from pressure data is similar to the diffusivity estimated from the distributed strain. These results indicated that the CMPI distributed strain measurement system could be used to improve monitoring and characterization of the vadose and underlying saturated zone.

Hua, Liwei↗

Four-Stage Multi-Physics Simulations to Assist Temperature Sensor Design for Industrial-Scale Coal-Fired Boiler

The growth of renewable energy sources presents a pressing challenge to the operation and maintenance of existing fossil fuel power plants, given that fossil fuel remains the predominant fuel source, responsible for over 60% of electricity generation in the United States. One of the main concerns within these fossil fuel power plants is the unpredictable failure of boiler tubes, resulting in emergency maintenance with significant economic and societal consequences. A reliable high-temperature sensor is necessary for in situ monitoring of boiler tubes and the safety of fossil fuel power plants. In this study, a comprehensive four-stage multi-physics computational framework is developed to assist the design, optimization installation, and operation of the high-temperature stainless-steel and quartz coaxial cable sensor (SSQ-CCS) for coal-fired boiler applications. With the consideration of various operation conditions, we predict the distributions of flue gas temperatures within coal-fired boilers, the temperature correlation between the boiler tube and SSQ-CCS, and the safety of SSQ-CCS. With the simulation-guided sensor installation plan, the newly designed SSQ-CCSs have been employed for field testing for more than 430 days. The computational framework developed in this work can guide the future operation of coal-fired plants and other power plants for the safety prediction of boiler operations.

42 ENGINEERING↗

Robust In-Situ Strain Measurements to Monitor CO 2 Storage

The goal of this project was to develop and demonstrate robust instrumentation to monitor the in-situ strain tensor in order to improve the reliability and security of CO 2 storage in geologic formations. We met the original goals of the project and the major overarching accomplishment is the advancement of strain tensor monitoring from an intriguing concept to a commercially available technology with a solid foundation of novel instruments supported by theoretical analyses and validation experiments. The main accomplishments of the project are summarized below. We designed, built and evaluated nine new optical fiber strainmeters and tiltmeters using Michelson interferometers to measure deformation with ultra-high resolution at both shallow and deep point locations in the subsurface. These are the robust strainmeters that motivated the title of the project. We designed, built and evaluated a novel method of measuring distributed strain in optical fibers with nanostrain resolution, and cm-scale location, and sampling into the seismic band. The new method is called Coherence-length-gated Microwave Photonics Interfereometry (CMPI). CMPI technology has advantages over existing commercial DAS and DSS methods. We developed and demonstrated capabilities to deploy instruments in the field and used them to measure strain caused by ambient signals like barometric pressure and tides, as well as induced signals like surface loading and pore pressure changes from pumping tests. We deployed a working strainmeter at 1,700 ft depth, slightly above an active reservoir. This is to our knowledge the greatest depth a strainmeter has been deployed and the techniques we used can readily be extended to greater depths. Optical fiber borehole tensor strainmeter techology was advanced from a TRL 4 at the start, to a TRL of 7 at the conclusion of the project. The project included advances in simulations and theoretical analyses. We developed and demonstrated a computational workflow that uses machine learning to reduce the computational requirements and make it practical to use Bayesian inversion to solve large numerical poroelastic analyses needed to interpret strain tensor field data. We evaluated the strain tensor fields and time series that would be caused by leaks of CO 2 or other fluids from reservoirs. These simulations demonstrated that signals from leaks could be measured with instruments developed for the project, opening a potentially new method for ensuring storage security. We showed that strains in caprock can be used to estimate pressure in a reservoir. This avoids the need to drill monitoring wells into the reservoir, and it expands the capabilities of monitoring in the caprock. The project includes a derivation and application of a novel analytical solution to the strains in the vicinity of a pressurized poroelastic inclusion. This solution explains field data measured during injeciton tests at the North Avant Field, and it will simplify future interpretation of strain tensor data. The project included a broad range of experiments, and of the most significant is the characterization of the strain tensor at an array three strainmeters during six injection tests at the North Avant Field, Oklahoma. This demonstrated repeatability of the strain signal measured by the new instruments developed for the project, and it showed similarities between the strain signal at shallow depths and pressure in the underlying reservoir. We also demonstrated that useful strain data can be measured at reservoir depths. This confirms that strain tensor data can be measured throughout the caprock over a reservoir. The project demonstrated the feasibility of using the strain tensor and distributed strain measured in caprock during a variety of different well tests where the pumping rate was constant, sinusoidal and positive, or a periodic square wave with zero net rate. This further strengthens the validity of using strain data to characterize reservoirs and aquifers. We also demonstrated that strain caused be fluctuations of air pressure and water pressure in the vadose zone can be measured and interpreted, suggesting that high resolution distributed strain measurements hold promise for monitoring the vadose zone. The project partially supported nine graduate students in the Environmental Engineering, Hydrogeology, Electrical Engineering programs at Clemson University. The research was described in nine journal papers, 23 talks and conference abstracts. Additional journal papers are in preparation. A new company called Tensora was started to provide strainmeter technology for commercial applications.

01 COAL, LIGNITE, AND PEAT↗

Distributed Coaxial Cable Sensors for In-Situ Condition Based Monitoring of Coal-Fired Boiler Tubes

The increasing contributions of renewable energy sources present new challenges to the operation and maintenance of the existing coal-fired power plants. One of the major operational risks is the unexpected failure of superheater boiler tubes, leading to the most unplanned power plant outrages. The boiler tube failure is difficult to predict due to the harsh operating environments. Therefore, condition-based monitoring (CBM) with a reliable high temperature sensor becomes necessary to produce a meaningful assessment of the health condition of boiler tubes and their remaining lifetime. In this work, the stainless-steel and quartz coaxial cable sensor (SSQ-CCS) is proposed for in-situ distributed monitoring of the boiler tube temperatures in existing coal-fired power plants. Comprehensive tests have been conducted with an in-house testing facility at Clemson University to study and evaluate the sensors’ performance in the temperature range of 100℃ to 600℃. The results indicated that the measurement resolution of the SSQ-CCS sensor is better than 1℃, and the drift is less than 2% over long-period testing. Meanwhile, multi-physics finite element analysis has been conducted to optimize the design and evaluate the safety of the SSQ-CCS temperature sensor under various operational conditions. Based on the performance obtained in the laboratory-scale testing, a field test has been implemented at a power plant. Four SSQ-CCS temperature sensors were installed for in-situ monitoring of the temperatures of a power plant’s superheat tube assembles. The data acquisition system has been successfully set up and collected sensing signals for more than three months. The sensing signals have been post-processed, and the monitored temperature history through the SSQ-CCS temperature sensor has been validated and compared with the conventional high temperature thermal couple data.

Jiao, Xinyu↗

Glass Additive and Subtractive Manufacturing of a Fiber Optic Rotary Encoder for Downhole Pressure Sensing

This article presents a fiber optic rotary encoder-based pressure sensor for downhole applications. The rotary encoder, which is composed of an encoding pad and an all-glass optical fiber sensing head, converts the rotation angles of a pressure transducer to digital codes. The optical fiber only serves as the telemetry channel to directly transmit the data in digital format such that the environmental temperature influence and the long-time drift are minimized. The glass additive and subtractive manufacturing (ASM) techniques are used to embed the multichannel optical fibers into a bulk-fused silica glass substrate. Because the fused silica glass shares a similar material property to the optical fiber (e.g., thermal expansion coefficient), the optical fiber sensing head is well sealed and fixed even at an elevated temperature. The picosecond laser blackening technique is used to fabricate the high reflectivity contrast encoding pad with high accuracy. Here, the proposed pressure sensor was manufactured and experimentally verified to have a signal-to-noise ratio (SNR) of 23 dB and a linear pressure response with a root-mean-square error (RMSE) of 0.37. During the 400-h 250 °C long-term stability test, there was no digital code variation. In addition, a mathematical model to study the relationships between the sensor’s performances and design parameters was established. According to the model, a 12-bit encoder (0.02% pressure sensitivity) can be achieved with a radius of 20 mm.

02 PETROLEUM↗

Distributed Acoustic Sensing Based on Coherent Microwave Photonics Interferometry

A microwave photonics method has been developed for measuring distributed acoustic signals. This method uses microwave-modulated low coherence light as a probe to interrogate distributed in-fiber interferometers, which are used to measure acoustic-induced strain. By sweeping the microwave frequency at a constant rate, the acoustic signals are encoded into the complex microwave spectrum. The microwave spectrum is transformed into the joint time–frequency domain and further processed to obtain the distributed acoustic signals. The method is first evaluated using an intrinsic Fabry Perot interferometer (IFPI). Acoustic signals of frequency up to 15.6 kHz were detected. The method was further demonstrated using an array of in-fiber weak reflectors and an external Michelson interferometer. Two piezoceramic cylinders (PCCs) driven at frequencies of 1700 Hz and 3430 Hz were used as acoustic sources. The experiment results show that the sensing system can locate multiple acoustic sources. The system resolves 20 nε when the spatial resolution is 5 cm. The recovered acoustic signals match the excitation signals in frequency, amplitude, and phase, indicating an excellent potential for distributed acoustic sensing (DAS).

47 OTHER INSTRUMENTATION↗