Transducers for ultrasonic limb plethysmography

The design, construction, and performance characteristics of ultasonic transducers suitable for limb plethysmography are presented. Both 3-mm-diameter flat-plate and 12-mm-diameter hemispheric ceramic transducers operating at 2 MHz were fitted in 1-mm thick epoxy-resin lens/acoustic-coupling structures and mounted in exercie-EKG electrode housings for placement on the calf using adhesive collars. The effects of transducer directional characteristics on performance under off-axis rotation and the electrical impedances of the transducers were measured: The flat transducer was found to be sensitive to rotation and have an impedance of 800 ohms; the hemispheric transducer, to be unaffected by rotation and have an impedance of 80 ohms. The use of hemispheric transducers as both transmitter and receiver, or of a flat transducer as transmitter and a hemispheric transducer as receiver, was found to produce adequate dimensional measurements, with minimum care in transducer placement, in short-term physiological experiments and long-term (up to 7-day) attachment tests.

Nickell, W. T.

A practical ultrasonic plethysmograph

An ultrasonic plethysmograph, which gives improved performance over the standard Whitney Strain Gauge, is described. This instrument monitors dimension changes in human limbs by measuring the transit times of acoustic pulses across two chords of the limb. In the case of a small uniform expansion, the percentage change in limb volume is shown to be proportional to twice the percentage change in either of the measured chords. Measurement of two chords allows correction for possible non-uniform expansion. In addition, measurement of two chords allows an estimate of the absolute cross-sectional area of the limb. The developed instrument incorporates a microprocessor, which performs necessary calculation and control functions. Use of the microprocessor allows the instrument to be self-calibrating. In addition, the device can be easily reprogrammed to incorporate improvements in operating features or computational schemes.

Wu, V. C.

Microprocessor-controlled ultrasonic plethysmograph

Safe, nonintrusive microprocessor system times ultrasonic pulses to measure limb cross-sectional area. Simple instrument requires no calibration and does not confine leg movement, making tests relating limb volume to activity level possible. Program considers more realistic geometries of human limb than circular cross-sections and monitors changes in area with great accuracy. Errors due to body temperature changes and timing roundoff are insignificant.

Bhagat, P. K.

Apparatus for determining changes in limb volume

Measuring apparatus for determining changes in the volume of limbs or other boty extremities by determining the cross-sectional area of such limbs many comprise a transmitter including first and second transducers for positioning on the surface of the limb at a predetermined distance there between, and a receiver including a receiver crystal for positioning on the surface of the limb. The distance between the receiver crystal and the first and second transducers are represented by respective first and second chords of the cross-section of the limb and the predetermined distance between the first and second transducers is represented by a third chord of the limb cross section.