Engineering topics
Wu, Q.
Publications and source records attributed to Wu, Q..
Beam energy scan with asymmetric collision at RHIC
A beam energy scan of deuteron-gold collision, with center-of-mass energy at 19.6, 39, 62.4 and 200.7 GeV/n, was performed at the Relativistic Heavy Ion Collider in 2016 to study the threshold for quark-gluon plasma (QGP) production. The lattice, RF, stochastic cooling and other subsystems were in different configurations for the various energies. The operational challenges changed with every new energy. The operational experience at each energy, the operation performance, highlights and lessons of the beam energy scan are reviewed in this report.
SMR Re-Scaling and Modeling for Load Following Studies
This study investigates the creation of a new set of scaling parameters for the Oregon State University Multi-Application Small Light Water Reactor (MASLWR) scaled thermal hydraulic test facility. As part of a study being undertaken by Idaho National Lab involving nuclear reactor load following characteristics, full power operations need to be simulated, and therefore properly scaled. Presented here is the scaling analysis and plans for RELAP5-3D simulation.
Gravity-Based Non-Invasive System for Reactor Coolant Inventory Monitoring
This paper summarizes the progress in the use of non-invasive methods for measuring liquid level in small modular nuclear reactors. High precision gravimeters are used to measure changes in liquid level in a test facility environment, and results are compared to simulations. Possible configurations for the meters use in the NuScale SMR are also discussed. (authors)
SMR Re-Scaling and Modeling for Load Following Studies
This study investigates the creation of a new set of scaling parameters for the Oregon State University Multi-Application Small Light Water Reactor (MASLWR) scaled thermal hydraulic test facility which modeled the NuScale power SMR design. As part of a study being undertaken by Idaho National Lab involving nuclear reactor load following characteristics, full power operations need to be simulated, and therefore properly scaled. Presented here is the scaling analysis and plans for RELAP5-3D simulation. (authors)
MO-D-BRC-03: Knowledge-Based Planning
Treatment planning is a central part of radiation therapy, including delineation in tumor volumes and critical organs, setting treatment goals of prescription doses to the tumor targets and tolerance doses to the critical organs, and finally generation of treatment plans to meet the treatment goals. National groups like RTOG have led the effort to standardize treatment goals of the prescription doses to the tumor targets and tolerance doses to the critical organs based on accumulated knowledge from decades of abundant clinical trial experience. The challenge for each clinical department is how to achieve or surpass these set goals within the time constraints of clinical practice. Using fifteen testing cases from different treatment sites such as head and neck, prostate with and without pelvic lymph nodes, SBRT spine, we will present clinically utility of advanced planning tools, including knowledge based, automatic based, and multiple criteria based tools that are clinically implemented. The objectives of this session are: Understand differences among these three advanced planning tools Provide clinical assessments on the utility of the advanced planning tools Discuss clinical challenges of treatment planning with large variations in tumor volumes and their relationships with adjacent critical organs. Ping Xia received research grant from Philips. Jackie Wu received research grant from Varian; P. Xia, Research support by Philips and Varian; Q. Wu, NIH, Varian Medical.
TH-AB-BRB-02: ET-Reloaded
Current state-of-the art digital C-arm medical linear accelerators are capable of delivering radiation treatments with high level of automation, which affords coordinated motions of gantry, couch, and multileaf collimator (MLC) with dose rate modulations. The new machine capacity has shown the potential to bring substantially improved radiation dosimetry and/or delivery efficiency to many challenging diseases. Combining an integrated beam orientation optimization algorithm with automated machine navigation, markedly improved dose conformity has been achieved using 4ρ therapy. Trajectory modulated radiation therapy (TMAT) can be used to deliver highly conformal dose to partial breast or to carve complex dose distribution for therapy involving extended volumes such as total marrow and total lymph node treatment. Dynamic electron arc radiotherapy (DEAR) not only overcomes the deficiencies of conventional electron therapy in dose conformity and homogeneity but also achieves so without patient-specific shields. The combination of MLC and couch tracking provides improved motion management of thoracic and abdominal tumors. A substantial body of work has been done in these technological advances for clinical translation. The proposed symposium will provide a timely review of these exciting opportunities. Learning Objectives: Recognize the potential of using digitally controlled linacs for clinically significant improvements in delivered dose distributions for various treatment sites. Identify existing approaches to treatment planning, optimization and delivery for treatment techniques utilizing the advanced functions of digital linacs and venues for further development and improvement. Understand methods for testing and validating delivery system performance. Identify tools available on current delivery systems for implementation and control for such treatments. Obtain the update in clinical applications, trials and regulatory approval. K. Sheng, NIH U19AI067769, NIH R43CA183390, NIH R01CA188300, Varian Medical Systems V. Yu, Varian Medical Systems, AAPM Summer Undergraduate Fellowship, NSF graduate fellowship S. Nill, Elekta AB. Cancer Research UK under Programme C33589/A19727, NIHR Biomedical Research Centre at The Royal Marsden and The Institute of Cancer Research.
Electronic origin of spatial self-phase modulation: Evidenced by comparing graphite with C{sub 60} and graphene
We report unambiguous observation of spatial self-phase modulation (SSPM) in a dispersive suspension of graphite flakes. This coherent nonlinear optical effect in bulk graphite is found to be broadband and large, with a third-order nonlinear susceptibility χ{sup (3)} of 2.2 × 10{sup −9} esu (i.e., 3.1 × 10{sup −17} m{sup 2}/V{sup 2} in SI units) at 532 nm excitation. Comparison with other carbon allotropes shows that this value is 5 × 10{sup 7} times higher than that of C{sub 60} but ∼50 times lower than that of graphene, fully exhibiting the electronic origin of SSPM.
Magnetic properties and coercivity mechanism of Sm{sub 1-x}Pr{sub x}Co{sub 5} (x=0-0.6) nanoflakes prepared by surfactant-assisted ball milling
Sm{sub 1-x}Pr{sub x}Co{sub 5} (x=0-0.6) nanoflakes with CaCu{sub 5} structure were successfully prepared by surfactant-assisted high-energy ball milling (SAHEBM). The crystal structure and magnetic properties of Sm{sub 1-x}Pr{sub x}Co{sub 5} (x=0-0.6) nanoflakes were studied by X-ray diffraction and vibrating sample magnetometer. Effects of Pr addition on the structure, magnetic properties and coercivity mechanism of Sm{sub 1-x}Pr{sub x}Co{sub 5} nanoflakes were systematically investigated. XRD results show that all the nanoflakes have a hexagonal CaCu{sub 5}-type (Sm, Pr){sub 1}Co{sub 5} main phase and the (Sm, Pr){sub 2}Co{sub 7} impurity phase, and all of the samples exhibit a strong (00l) texture after magnetic alignment. As the Pr content increases, remanence firstly increases, then slightly reduced, while anisotropy field (H{sub A}) and H{sub ci} of decrease monotonically. Maximum energy product [(BH){sub max}] of the flakes increases first, peaks at 24.4 MGOe with Pr content of x = 0.4, then drops again. Magnetization behavior analysis indicate that the coercivity mechanism is mainly controlled by inhomogeneous domain wall pinning, and the pinning strength weakens with the increased Pr content, suggesting the great influence of H{sub A} on the coercivity of flakes.
RF design of normal conducting 704 MHz and 2.1 GHz cavities for LEReC Linac
N/A
BNL 56 MHz HOM DAMPER FABRICATION AT JLAB
The Higher-Order Mode (HOM) Dampers for the Relativistic Heavy-Ion Collider’s (RHIC) 56 MHz cavity at Brookhaven National Laboratory (BNL) are currently being fabricated at JLab. The coaxial damper is primarily constructed with high RRR niobium, with a combination of niobium and sapphire rings as the filter assembly. Several design changes have been made with respect to the performance of a prototype damper – also fabricated at JLab – which was found to quench at low power. The production dampers are being tuned and tested in the JLab vertical test area (VTA) prior to delivery. Two HOM dampers will be delivered to BNL; they are to be used in the RHIC in November, 2015. This paper outlines the challenges faced in the fabrication and tuning process.