LOFA and LOCA analysis on CGNPC SCWR
Safety analysis is one of the chief difficulties during the research and design of SCWRs. At present, the development of SCWR safety analysis code is still in the initial stage all around the world, and very few computer codes could carry out trans-critical calculations where significant changes in water properties would take place. In this paper, a safety analysis code SCTRAN for SCWRs, has been developed based on RETRAN-02. The ability of SCTRAN code to simulate the transient where both supercritical and subcritical regimes are encountered has been verified by comparing with APROS code and RELAP5-3D code, respectively. With SCTRAN code, the preliminary LOFA and LOCA analysis of the SCWR design proposed by CGNPC, have been analyzed. The characteristics and performance of the passive safety systems applied to CGNPC-SCWR are evaluated. The results show that: 1) The SCTRAN computer code developed in this study is capable to carry out safety analysis for SCWRs, and its results are reliable; 2) During LOFA and LOCA accidents, very complex flow regime might take place in the double-pass core design, but the passive safety systems would greatly mitigate the consequences of these transients and increase the inherent safety. (authors)