Engineering Papers⌕ Search

Engineering topics

Wu, J.

Publications and source records attributed to Wu, J..

At least 253 records · Page 14

Commissioning of the LCLS LINAC

The Linac Coherent Light Source (LCLS) X-ray free electron laser project is currently under construction at the Stanford Linear Accelerator Center (SLAC). A new injector and upgrades to the existing accelerator were installed in two phases in 2006 and 2007. We report on the commissioning of the injector, the two new bunch compressors at 250MeV and 4.3 GeV, and transverse and longitudinal beam diagnostics up to the end of the existing linac at 13.6 GeV. The commissioning of the new transfer line from the end of the linac to the undulator is scheduled to start in November 2008 and for the undulator in March 2009 with first light to be expected in July 2009.

43 PARTICLE ACCELERATORS↗

Acute and Chronic Exposure to CO2 in Space Flight

Spacecraft and space stations, similar to other habitable confined spaces such as submarines, need to provide a breathable atmosphere for their inhabitants. The inevitable production of CO2 during respiration necessitates life support systems that "scrub" the atmosphere and lower CO2 levels. Due to operational limitations associated with space flight (limited mass, volume, power, and consumables) CO2 is not scrubbed down to its terrestrial equivalent of 0.03% CO2 (ppCO2 of 0.23 mmHg), but is kept below 0.7% (ppCO2 of 5.3 mmHg), a level established in NASA s 180-day mission Spacecraft Maximum Allowable Concentration (SMAC) to be safe and unlikely to cause symptoms. Reports of space flight crewmembers becoming symptomatic with headaches, fatigue, and malaise at levels below those known to cause such symptoms terrestrially has prompted studies measuring the levels of CO2 on both the space shuttle and the space station. Data from cabin atmosphere sampling were collected on space shuttle missions STS-113, STS-122, STS-123, and International Space Station Expeditions 12-15 and 17, and the measured CO2 levels were then correlated to symptoms reported by the crew. The results indicate that a correlation exists between CO2 levels and symptomatology, however causality cannot be established at this time. While the short-term effects of elevated CO2 exposure are well known terrestrially, less is known regarding potential long-term effects of prolonged exposure to a CO2-rich environment or how the physiological changes caused by microgravity may interact with such exposures. Other challenges include limitations in the CO2 monitors used, lack of convection in the microgravity environment, and formation of localized CO2 pockets. As it is unclear if the unique environment of space increases sensitivity to CO2 or if other confounding factors are present, further research is planned to elucidate these points. At the same time, efforts are underway to update the SMAC to a lower level

Alexander, D.↗

Systematics in the Electron Spectrum Measured by ATIC

An analysis of different parameters to separate electrons from protons in the ATIC experiment has been performed. Five separate discriminants were studied by different Monte Carlo programs, leading to a variety of results. Application to the ATIC data indicates the range of variation possible in the interpretation of the data. The results of this analysis, when compared with the published results [5], show good agreement in the most interesting region of energy (from 90 GeV to 600 GeV). The measured electron spectrum is compared with the recent data reported by Fermi/LAT, and there is no major disagreement between ATIC s results and Fermi/LAT. Finally, possible systematics-free, short energy scale features of the ATIC electron spectrum are mentioned. Keywords: ATIC, electron spectrum, fine structure

Panov, A. D.↗

Determining the Detection Efficiency and Background Level of ATIC Electron Observation from Flight Data

Observations of Cosmic-ray electrons are difficult due to the large flux of cosmic ray hadrons. The event selection efficiency and background levels can be estimated from flight data for the ATIC instrument. This reduces the dependence upon Monte Carlo simulations, which show differences between different codes, thereby reducing the systematic errors resulting from analyses that only use simulations. This paper discusses some of the methods used in the ATIC analysis to determine the detection efficiency and background level for the flight data.

Chang, J.↗

Observations of High Energy Cosmic Ray Electrons by the ATIC Balloon Experiment

Recently the Advanced Thin Ionization Calorimeter (ATIC) balloon experiment reported observations of high energy cosmic ray electrons over the energy range 300 to 800 GeV, indicating a feature or "bump" in the otherwise smoothly decreasing energy spectrum. The severe energy losses that occur as these high energy particles traverse the galaxy render the cosmic ray electron spectrum sensitive to local (a few kiloparsecs) sources and hence very interesting. The ATIC results are the first time that such a cosmic ray spectrum anomaly has been observed at high energy. Potential sources of this electron excess include pulsars, microquasars, supernovae remnants as well as the annihilation of exotic dark matter candidate particles. ATIC has had three successful high altitude flights over the continent of Antarctica 2000-2001, 2002-2003 and 2007-2008. Only results from the first two flights have been reported so far. During this talk we will discuss the ATIC experiment, the electron observations (including preliminary results from the most recent ATIC flight), examine the merits of the various source models and compare the ATIC observations with other recent measurements.

Guzik, T. G.↗

The Cosmic Ray Electron Excess

This slide presentation reviews the possible sources for the apparent excess of Cosmic Ray Electrons. The presentation reviews the Advanced Thin Ionization Calorimeter (ATIC) instrument, the various parts, how cosmic ray electrons are measured, and shows graphs that review the results of the ATIC instrument measurement. A review of Cosmic Ray Electrons models is explored, along with the source candidates. Scenarios for the excess are reviewed: Supernova remnants (SNR) Pulsar Wind nebulae, or Microquasars. Each of these has some problem that mitigates the argument. The last possibility discussed is Dark Matter. The Anti-Matter Exploration and Light-nuclei Astrophysics (PAMELA) mission is to search for evidence of annihilations of dark matter particles, to search for anti-nuclei, to test cosmic-ray propagation models, and to measure electron and positron spectra. There are slides explaining the results of Pamela and how to compare these with those of the ATIC experiment. Dark matter annihilation is then reviewed, which represent two types of dark matter: Neutralinos, and kaluza-Kline (KK) particles, which are next explained. The future astrophysical measurements, those from GLAST LAT, the Alpha Magnetic Spectrometer (AMS), and HEPCAT are reviewed, in light of assisting in finding an explanation for the observed excess. Also the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) could help by revealing if there are extra dimensions.

Chang, J.↗

Relative Abundances of Cosmic Ray Nuclei B-C-N-O in the Energy Region from 10 GeV/n to 300 GeV/n. Results from the Science Flight of the ATIC

The ATIC balloon-borne experiment measures the energy spectra of elements from H to Fe in primary cosmic rays from about 100 GeV to 100 TeV. ATIC is comprised of a fully active bismuth germanate calorimeter, a carbon target with embedded scintillator hodoscopes, and a silicon matrix that is used as a main charge detector. The silicon matrix produces good charge resolution for the protons and helium but only a partial resolution for heavier nuclei. In the present paper a charge resolution of ATIC device was essentially improved and backgrounds were reduced in the region from Be to Si by means of the upper layer of the scintillator hodoscope that was used as an additional charge detector together with the silicon matrix. The flux ratios of nuclei B/C, O/C, N/C in the energy region from about 10 GeV/nucleon to 300 GeV/nucleon that were obtained from new high-resolution and high-quality charge spectra of nuclei are presented. The results are compared with existing theoretical predictions.

Panov, A. D.↗

Revised Energy Spectra for Primary Elements, H - Si, above 50 GeV from the ATIC-2 Science Flight

The Advanced Thin Ionization Calorimeter (ATIC) long duration balloon experiment had a successful science flight accumulating 18 days of data (12/02 - 1/03) during a single circumnavigation in Antarctica. ATIC measures the energy spectra of elements from H to Fe in primary cosmic rays using a fully active Bismuth Germanate calorimeter preceded by a carbon target, with embedded scintillator hodoscopes, and a silicon matrix charge detector at the top. Preliminary results from ATIC have been reported in previous conferences. The revised results reported here are derived from a new analysis of the data with improved charge resolution, lower background and revised energy calibration. The raw energy deposit spectra are de-convolved into primary energy spectra and extrapolated to the top of the atmosphere. We compare these revised results to previous data and comment upon the astrophysical interpretation of the results.

Wefel, J. P.↗

All-Particle Spectrum Measured by the ATIC Experiment

The Advanced Thin Ionization Calorimeter (ATIC), a balloon-borne experiment, is designed to investigate the composition and energy spectra of cosmic rays of charge Z = 1 to 26 over the energy range - 10(exp 11) - 10(exp 14) ev. The instrument consists of a silicon matrix charge detector, plastic-scintillator strip hodoscopes interleaved with graphite interaction targets, and an 18 radiation length deep, fully active bismuth germanate (BGO) calorimeter. ATIC has had two successful long duration balloon (LDB) flights launched from McMurdo Station, Antarc't'ica in 2000 and 2002. In this paper, we present the all-particle spectrum extracted from data collected during the ATIC flights, and compare it with results from other experiments at both lower and higher energies.

Ahn, H. S.↗

Relative Fluxes of Primary Particles in B-C-N-O Group from the ATIC Experiment (Science Flight)

The ATIC balloon-born experiment measures the energy spectra of elements from H to Fe in primary cosmic rays from about 100 GeV to 100 TeV. ATIC is comprised of a fully active bismuth germinate calorimeter, a carbon target with embedded scintillator hodoscopes, and a silicon matrix that is used as a main charge detector. The silicon matrix produces good charge resolution for the protons and helium but only a partial resolution for heavier nuclei. In the present paper a charge resolution of ATIC device was improved and backgrounds were reduced in the region from Be to Si by means of the upper layer of the scintillator hodoscope that was used as charge detector together with silicon matrix. Relative fluxes of nuclei B, C, N, O in the energy region from about 20 GeV/nucleon to 200 GeV/nucleon that were obtained from new high-resolution and high-quality charge spectra of nuclei are presented.

Panov, A. D.↗

Comparison of Numerical Schemes for a Realistic Computational Aeroacoustics Benchmark Problem

In this work, a nonlinear structured-multiblock CAA solver, the NASA GRC BASS code, will be tested on a realistic CAA benchmark problem. The purpose of this test is to ascertain what effect the high-accuracy solution methods used in CAA have on a realistic test problem, where both the mean flow and the unsteady waves are simultaneously computed on a fully curvilinear grid from a commercial grid generator. The proposed test will compare the solutions obtained using several finite-difference methods on identical grids to determine whether high-accuracy schemes have advantages for this benchmark problem.

Hixon, R.↗

Deep space optical communications link availability and data volume

Optical links from a spacecraft at planetary distance to a ground-based receiver presume a cloud free line of site (CFLOS). Future ground-based optical reeiving networks, should they be implemented, will rely on site diversity of could cover to increase link availability.

optical communications↗

Composition Dependence of the Hydrostatic Pressure Coefficients of the Bandgap of ZnSe(1-x)Te(x) Alloys

Optical absorption experiments have been performed using diamond anvil cells to measure the hydrostatic pressure dependence of the fundamental bandgap of ZnSe(sub 1-xTe(sub x) alloys over the entire composition range. The first and second-order pressure coefficients are obtained as a function of composition. Starting from the ZnSe side, the magnitude of both coefficients increases slowly until x approx. 0.7, where the ambient-pressure bandgap reaches a minimum. For larger values of x the coefficients rapidly approach the values of ZnTe. The large deviations of the pressure coefficients from the linear interpolation between ZnSe and ZnTe are explained in terms of the band anticrossing model.

Wu, J.↗

Advanced Thin Ionization Calorimeter (ATIC) Update

The Advanced Thin Ionization Calorimeter (ATIC) experiment is designed to measure the composition and energy spectra of Z = 1 to 28 cosmic rays over the energy range of approximately 10 GeV - 100 TeV. ATIC is comprised of an eight-layer, 18 radiation length deep Bismuth Germanate (BGO) calorimeter, downstream of a 0.75 nuclear interaction length graphite target and an approximately 1 sq m finely segmented silicon charge detector. Interleaved with the graphite layers are three scintillator strip hodoscopes for pre-triggering and tracking. ATIC flew for the first time on a Long Duration Balloon (LDB) launched from McMurdo, Antarctica in January 2001. During its 16-day flight ATIC collected more than 30 million science events, along with housekeeping, calibration, and rate data. This presentation will describe the ATIC data processing, including calibration and efficiency corrections, and show results from analysis of this dataset. The next launch is planned for December 2002.

Ahn, H. S.↗

Origin of the Bandgap Bowing in ZNSe(1-x)Te(x) Alloys

Photomodulated reflection and optical absorption spectroscopies were used to measure the composition and hydrostatic pressure dependencies of interband optical transitions in ZnSe(1-x)Te(x) alloys. On the Te-rich side, the bandgap reduction and the reduction in the pressure dependence of the bandgap are well explained by the band anticrossing interaction between the ZnTe conduction band states and the Se localized state located at 2.85 eV above the valence band top of ZnTe. On the Se-rich side, an interaction between the degenerate Gamma valence bands of ZnSe and the localized Te state located at 0.1 eV above the valence band top of ZnSe is proposed to generate the bandgap reduction and the rapid increase of the spin-orbit splitting with increasing Te concentration. A linear interpolation between these two models accounts for the composition and pressure dependencies of the bandgap in the entire composition range.

Walukiewicz, W.↗

Origin of the Large Bandgap Bowing in Highly Mismatched Semiconductor Alloys

We use a combination of optical and soft x-ray fluorescence techniques to investigate the composition dependence of the band edge energies in ZnSe(1-x)Te(x) and ZnS(1-x)Te(x) alloys. The results reveal entirely different origins of the large bandgap bowing for alloys with small and large Te content. On the Te-rich side, the reduction of the bandgap is well explained by the band anticrossing interaction between the Se or S localized states and the ZnTe conduction band states. On the Se or S-rich side, an interaction between the localized Te states and the degenerate GAMMA valence bands of ZnSe or ZnS is responsible for the bandgap reduction and the rapid increase of the spin-orbit splitting with increasing Te concentration. Results of soft x-ray fluorescence experiments provide direct evidence for the valence band anticrossing interaction. The bandgap bowing over the entire composition range is accounted for by a linear interpolation between the conduction band anticrossing and valence band anticrossing models.

Wu, J.↗

Increased renal tubular sodium reabsorption during exercise-induced hypervolemia in humans

We tested the hypothesis that renal tubular Na(+) reabsorption increased during the first 24 h of exercise-induced plasma volume expansion. Renal function was assessed 1 day after no-exercise control (C) or intermittent cycle ergometer exercise (Ex, 85% of peak O(2) uptake) for 2 h before and 3 h after saline loading (12.5 ml/kg over 30 min) in seven subjects. Ex reduced renal blood flow (p-aminohippurate clearance) compared with C (0.83 +/- 0.12 vs. 1.49 +/- 0.24 l/min, P < 0.05) but did not influence glomerular filtration rates (97 +/- 10 ml/min, inulin clearance). Fractional tubular reabsorption of Na(+) in the proximal tubules was higher in Ex than in C (P < 0.05). Saline loading decreased fractional tubular reabsorption of Na(+) from 99.1 +/- 0.1 to 98.7 +/- 0.1% (P < 0.05) in C but not in Ex (99.3 +/- 0.1 to 99.4 +/- 0.1%). Saline loading reduced plasma renin activity and plasma arginine vasopressin levels in C and Ex, although the magnitude of decrease was greater in C (P < 0.05). These results indicate that, during the acute phase of exercise-induced plasma volume expansion, increased tubular Na(+) reabsorption is directed primarily to the proximal tubules and is associated with a decrease in renal blood flow. In addition, saline infusion caused a smaller reduction in fluid-regulating hormones in Ex. The attenuated volume-regulatory response acts to preserve distal tubular Na(+) reabsorption during saline infusion 24 h after exercise.

NASA Discipline Cardiopulmonary↗