Engineering PapersSearch

Engineering topics

Woods, P. M.

Publications and source records attributed to Woods, P. M..

At least 19 records

On the Extended Emission of the Anomalous X-ray Pulsar IE 1547.0-5408

We present an analysis of the extended emission around the anomalous X-ray pulsar IE 1547.0-5408 using four XMM-Newton observations taken with the source in varying states of outburst as well as in quiescence. We find that the extended emission flux is highly variable and strongly correlated with the flux of the magnetar. Based on this result, as well as on spectral and energetic considerations, we conclude that the extended emission is dominated by a dust-scattering halo and not a pulsar wind nebula (P-VVN), as has been previously argued. We obtain an upper limit on the 2-10 keV flux of a possible PWN of 4.7 x 10(exp -14) erg/s/sq cm, three times less than the previously claimed value, implying an efficiency for conversion of spin-down energy into nebular luminosity of <9 x 10(exp -4) .

Olausen, S. A.

Chandra and RXTE Observations of 1E 1547.0-5408: Comparing the 2008 and 2009 Outbursts

We present results from observations of the magnetar 1E 1547.0-5408 (SGR J1550-5418) taken with the Chandra X-ray Observatory and the Rossi X-ray Timing Explorer (RXTE) following the source s outbursts in 2008 October and 2009 January. During the time span of the Chandra observations, which covers days 4 through 23 and days 2 through 16 after the 2008 and 2009 events, respectively, the source spectral shape over the Chandraband remained stable, while the pulsar s spindown rate in the same span in 2008 increased by a factor of 2.2 as measured by RXTE. This suggests decoupling between the source s spin-down and radiative changes, hence between the spin-down-inferred magnetic field strength and that inferred spectrally. The lack of spectral variation during flux decay is surprising for models of magnetar outbursts. We also found a strong anti-correlation between the phase-averaged flux and the pulsed fraction in the 2008 and 2009 Chandra data, but not in the pre-2008 measurements. We discuss these results in the context of the magnetar model.

Ng, C.-Y.

Magnetar-Like Emission from the Young Pulsar in Kes 75

We report the detection of magnetar-like x-ray bursts from the young pulsar PSR J1846-0258, at the center of the supernova remnant Kes 75. This pulsar, long thought to be exclusively rotation-powered, has an inferred surface dipolar magnetic field of 4.9deg 10(exp 13) gauss, which is higher than those of the vast majority of rotation-powered pulsars, but lower than those of the approximately 12 previously identified magnetars. The bursts were accompanied by a sudden flux increase and an unprecedented change in timing behavior. These phenomena lower the magnetic and rotational thresholds associated with magnetar-like behavior and suggest that in neutron stars there exists a continuum of magnetic activity that increases with inferred magnetic field strength.

Gavriil, F. P.

Evidence for a Binary Companion to the Enigmatic Compact Central Object 1E 1207.4-5209

Located in the supernova remnant G296.5+10.0, 1E 1207.4-5209 is a 0.424 s period X-ray pulsar that exhibits strong absorption lines in its energy spectrum. The physical origin of the spectral features in 1E 1207.4-5209 and more generally, the absence of similar features in other radio-quiet neutron stars remains a mystery. Another, possibly related, anomalous property of 1E 1207.4-5209 is its non-monotonic spin frequency evolution. Zavlin, Pavlov & Sanwal(2004) proposed that the irregular spin-down was caused by either (i) frequent, recurrent glitches, (ii) the presence of a fall-back disk or (iii) a binary companion. Here, we report on a sequence of seven XMM-Newton observations of 1E 1207.4-5209 performed during a 40 day window between 2005 June 22 and July 3 1. Due to unanticipated phase noise, we identified three statistically-acceptable phase-coherent timing solutions with frequency time derivatives of +0.9, -2.6, and +1.6 x 10-12 Hz/s (listed in descending order of significance). We concluded that the local frequency derivative during our XMM-Newton observing campaign differs from the long-term spin-down rate by more than an order of magnitude. This measurement strongly supports the binary interpretation for the observed spin irregularities in 1E 1207.4-5209. We identified a family of orbital solutions that are consistent with our phase-connected solution as well as all archival data. We will discuss possible orbital solutions, prospects for constraining binary parameters with future observations, and consequences for the nature of 1E 1207.4-5209.

Woods, P. M.

Soft Gamma Repeaters and Anomalous X-ray Pulsars: Magnetar Candidates

This article is a review of Soft Gamma Repeaters and Anomalous X-ray Pulsars. It contains a brief historical record of the emergence of these classes of neutron stars, a thorough overview of the observational data, a succinct summary of the magnetar model, and suggested directions for future research in this field.

Woods, P. M.

Changes in the X-Ray Emission from the Magnetar Candidate 1E 2259+586 During its 2002 Outburst

An outburst of more than 80 individual bursts, similar to those seen from Soft Gamma Repeaters (SGRs), was detected from the anomalous X-ray pulsar (AXP) 1E 2259+586 in 2002 June. Coincident with this burst activity were gross changes in the pulsed flux, persistent flux, energy spectrum, pulse profile, and spin-down of the underlying X-ray source. We present Rossi X-Ray Timing Explorer and X-Ray Multi-Mirror Mission observations of 1E 2259+586 that show the evolution of the aforementioned source parameters during and following this episode and identify recovery timescales for each. Specifically, we observe an X-ray flux increase (pulsed and phase-averaged) by more than an order of magnitude having two distinct components. The first component is linked to the burst activity and decays within approx. 2 days, during which the energy spectrum is considerably harder than during the quiescent state of the source. The second component decays over the year following the glitch according to a power law in time with an exponent -0.22 +/- 0.01. The pulsed fraction decreased initially to approx. 15% rms but recovered rapidly to the preoutburst level of approx. 23% within the first 3 days. The pulse profile changed significantly during the outburst and recovered almost fully within 2 months of the outburst. A glitch of size Delta(sib (nu)max) = (4.24 +/- 0.11) x 10(exp -6) was observed in 1E 2259+586, which preceded the observed burst activity. The glitch could not be well fitted with a simple partial exponential recovery. An exponential rise of approx. 20% of the frequency jump with a timescale of approx. 14 days results in a significantly better fit to the data; however, contamination from a systematic drift in the phase of the pulse profile cannot be excluded. A fraction of the glitch (approx. 19%) was recovered in a quasi-exponential manner having a recovery timescale of approx. 16 days. The long-term postglitch spin-down rate decreased in magnitude relative to the preglitch value. The changes in the source properties of 1E 2259+586 during its 2002 outburst are shown to be qualitatively similar to changes seen during or following burst activity in two SGRs, thus further solidifying the common nature of SGRs and AXP's as magnetars. The changes in persistent emission properties of 1E 2259+586 suggest that the star underwent a plastic deformation of the crust that simultaneously impacted the superfluid interior (crustal and possibly core superfluid) and the magnetosphere. Finally, the changes in persistent emission properties coincident with burst activity in 1E 2259+586 enabled us to infer previous burst-active episodes from this and other AXP's. The nondetection of these outbursts by all-sky gamma-ray instruments suggests that the number of active magnetar candidates in our Galaxy is larger than previously thought.

Woods, P. M.

The 2001 April Burst Activation of SGR 1900-14: Pulse Properties and Torque

We report on observations of SGR 1900+14 made with the Rossi X-Ray Timing Explorer (RXTE) and BeppoSAXduring the 2001 April burst activation of the source. Using these data, we measure the spin-down torque on the star and confirm earlier findings that the torque and burst activity are not directly correlated. We compare the X-ray pulse profile to the gamma-ray profile during the April 18 intermediate flare and show that (1) their shapes are similar and (1) the gamma-ray profile aligns closely in phase with the X-ray pulsations. The good phase alignment of the gamma-ray and X-ray profiles suggests that there was no rapid spin-down following this flare of the magnitude inferred for the August 27 giant flare. We discuss how these observations further constrain magnetic field reconfiguration models for the large flares of SGRs.

Woods, P. M.

Unraveling the Cooling Trend of the Soft Gamma Repeater SGR 1627-41

SGR 1627-41 was discovered in 1998 after a single active episode that lasted approximately 6 weeks. We report here our monitoring results of the decay trend of the persistent X-ray luminosity of the source during the last 5 years. We find an initial temporal power-law decay with index 0.47, reaching a plateau that is followed by a sharp (factor of 10) flux decline approximately 800 days after the source activation. The source spectrum is best described during the entire period by a single power law with high absorption [N(sub H) = 9.0(7) x 10(exp 22) per square centimeter]; the spectral index, however, varies dramatically between 2.2 and 3.8 spanning the entire range for all known soft gamma repeater sources. We discuss the cooling behavior of the neutron star assuming a deep crustal heating initiated by the burst activity of the source during 1998.

Kouveliotou, C.

The Peculiar X-ray Transient IGR 16358-4726

The new transient IGR 16358-4726 was discovered on 2003 March 19 with INTEGRAL. We detected the source serendipitously during our 2003 March 24 observation of SGR 1627 - 4lwith the Chandra X-ray observatory at the 1.7 x 10(exp -l0) ergs/s sq cm flux level ( 2-10 keV) with a very high absorption column (N_H = 3.3 x 10(exp 23)/sq cm and a hard power law spectrum of index 0.5(1). We discovered a very strong flux modulation with a period of 5880(50) s and peak-to-peak pulse fraction of 70(6)% (2-10 keV), clearly visible in the X-ray data. The nature of IGR 16358-4726 remains unresolved. The only neutron star systems known with similar spin periods are low luminosity persistent wind-fed pulsars; if this is a spin period, this transient is a new kind of object. If this is an orbital period, then the system could be a compact Low Mass X-ray Binary (LMXB).

Patel, S. K.

Unraveling the Cooling Trend of the Soft Gamma Repeater, SGR162-41

SGR 1627-41 was discovered in 1998 after a single active episode which lasted approx. 6 weeks. We report here our monitoring results of the decay trend of the persistent X-ray luminosity of the source during the last 5 years. We find an initial temporal power law decay with index 0.47, reaching a piateau which is followed by a sharp (factor of ten) flux decline approx. 800 days after the source activation. The source spectrum is best described during the entire period by a single power law with high absorption (N(sub H) = 9.0(7) x 10(exp 22)/sq cm); the spectral index, however, varies dramatically between 2.2-3.8 spanning the entire range for all known SGR sources. We discuss the cooling behavior of the neutron star assuming a deep crustal heating initiated by the burst activity of the source during 1998.

Kouveliotou, C.

Long-Term Spectral and Timing Behavior of Black Hole Candidate XTE J1908+094

The X-ray transient XTE J1908+094 was serendipitously discovered during RXTE ToO observations of SGR 1900+14 in February 2002. Following the discovery, RXTE routinely monitored the region. At the onset, the source was found in a spectrally low/hard state lasting for approximately 40 days, followed by a quick transition to the highhoft state. At the highest X-ray intensity level (seen on 2002 April 6), the source flux (2-10 keV) reached approximately 105 mCrab, then decayed rapidly. Overall outburst characteristics resemble the transient behavior of galactic black hole candidates. Here, we present the long term light curves, and detailed spectral and timing investigations of XTE J1098+094 using the RXTE/PCA data. We also report the results of Chandra ACIS observations which were performed during the decay phase.

Gogus, E.

Changes in the X-ray Emission from the Magnetar Candidate 1E 2259+586 during its 2002 Outburst

An outburst of more thm 80 individual bursts, similar to those see^ from Soft Gamma Repeaters (SGRs), was detected from the Anomalous X-ray Pulsar (AXP) 1E 2259+586 in 2002 June. Coincident with this burst activity were gross changes in the pulsed flux, persistent flux, energy spectrum, pulse profile and spin down of the underlying X-ray source. We present Rossa X-ray Tirnsng Explorer and X-ray Multi-Mirror Mission observations of 1E 2259+586 that show the evolution of the aforementioned source parameters during and following this episode and identify recovery time scales for each. Specifically, we observe an X-ray flux increase (pulsed and phase-averaged) by more than an order of magnitude having two distinct components. The first component is linked to the burst activity and decays within approx. 2 days during which the energy spectrum is considerably harder than during the quiescent state of the source. The second component decays over the year following the glitch according to a power law in time with an exponent -0.22+/-0.01. The pulsed fraction decreased initially to approx. 15% RMS, but recovered rapidly to the pre-outburst level of approx. 2 3 % within the first three days.

Woods, P. M.

Using the Chandra Project to Communicate with Underdeveloped Constituencies

We have instituted a program whose goal is to better communicate astronomy among students selected from an economically underprivileged area of Huntsville, Alabama. To achieve this goal, six local teachers were trained as astronomy teacher resource agents. These teachers were teamed with six scientists; the teams presented materials for 29 teachers, mostly from the Southeastern United States Topics included the electromagnetic spectrum, X-ray optics, gratings and spectroscopy, supernovae (and remnants), black holes, and the tools and techniques to analyze Chandra X-ray data. Beginning in September our teacher-scientist teams, in collaboration with the Huntsville Housting Authority, will present programs to specially selected students at the rate of one or two per month, until April 2004. These young people will be mentored and encouraged to develop a research project. Students, which complete a project by April 2, will be paid for their work.

Adams, M. L.

The Precise Location of the Soft Gamma Repeater SGR 1627-41 with Chandra

We report the precise localization of the Soft Gamma Repeater SGR 1627-41 with the Chandra X-ray Observatory. The best position for SGR 1627-41 was determined to be RA=16:35:51.844, DEC=-47:35:23.31 (J2000) with an accuracy of 0.6 arcsec. We present the results of our search for an IR counterpart to SGR 1627-41 and compare our results to the existing detections and limits of other magnetar infrared and optical observations in the literature. We also present new observations of SGR 1806-20 obtained during the recent reactivation of the source. In addition, we have determined a precise location for archival Chandra observations and reanalyzed archival IR data in the search for a counterpart.

Wachter, S.

A Comprehensive Study of Pulse Profile Evolution in SGR 1806-20 and SGR 1900+14 with the RXTE/PCA

Soft Gamma Repeaters undergo pulse profile changes in connection with the burst activity. Here we construct a comprehensive pulse profile history of SGR 1806-20 and SGR 1900+14 in different energy bands using Rossi X-ray Timing Explorer/Proportional Counter Array observations. We quantify the pulse profile evolution using the Fourier harmonic powers of profiles. Moreover, we determined the RMS pulsed count rates (PCRs) of each profile. We show that the pulse profiles SGR 1806$-$20 remain as single pulsed while those of SGR 1900+14 alter remarkable in all energy bands. Highly significant pulsations form SGR 1900+14 following August 27 and April 19 bursts enabled us to study not only decay of PCRs in different energy bands and also their correlations with one another.

Gogus, E.

XTE J1908+094

Goddard Space Flight Center reports the serendipitous discovery of a new x-ray transient, XTE J1908+094, in RXTE (Rossi X-ray Timing Explorer) PCA (Proportional Counter Array) observations of the soft-gamma-ray repeater SGR 1900+14, triggered following the burst activity on Feb. 17-18 (GCN 1253). These observations failed to detect the 5.2-s SGR pulsations, pointing towards a possible new source as the origin of the high x-ray flux. An RXTE PCA scan of the region around SGR 1900+14 on Feb. 21 was consistent with emission only from known sources (and no new sources). However, the scans required SGR 1900+14 to be 20 times brighter than its quiescent flux level (GCN 1256). A Director's Discretionary Time Chandra observation on Mar. 11 showed that the SGR was quiescent and did not reveal any new source within the Chandra ACIS (Advanced CCD (charge coupled device) Imaging Spectrometer) field-of-view. A subsequent RXTE PCA scan on Mar. 17, taken in combination with the first scan, required that a new source be included in the fit. The best-fit position is R.A. 19h 08m 50s, Decl. = +9 22 deg .5 (equinox J2000.0; estimated 2 deg systematic error radius), or approximately 24 deg away from the SGR source. The source spectrum (2-30 kev) can be best fit with a power-law function including photoelectric absorption (column density N_h = 2.3 x 10(exp 22), photon index = 1.55). Iron line emission is present, but may be due to the Galactic ridge. Between Feb. 19 and Mar. 17, the source flux (2-10 keV) has risen from 26 to 64 mCrab. The power spectrum is flat between 1 mHz and 0.1 Hz, falling approximately as 1/f**0.5 up to 1 Hz. At 1 Hz is seen a broad quasiperiodic oscillation peak and a break to a 1/f**2 power law, which continues to 4 Hz. The fractional rms (root mean square) amplitude from 1 mHz to 4 Hz is 43 percent. No coherent pulsations are seen between 0.001 and 1024 Hz. The authors conclude that XTE J1908+094 is a new blackhole candidate.

Woods, P. M.

The 2001 April Burst Activation of SGR 1900+14: Pulse Properties and Torque

We report on observations of SGR 1900+14 made with the Rossi X-ray Timing Explorer (RXTE) and BeppoSAX during the April 2001 burst activation of the source. Using these data, we measure the spindown torque on the star and confirm earlier findings that the torque and burst activity are not directly correlated. We compare the X-ray pulse profile to the gamma-ray profile during the April 18 intermediate flare and show that (i) their shapes are similar and (ii) the gamma-ray profile aligns closely in phase with the X-ray pulsations. The good phase alignment of the gamma-ray and X-ray profiles suggests that there was no rapid spindown following this flare, in contrast to the August 27 giant flare. The absence of rapid spindown in the hours following the April 18 flare suggests that there was no significant outflow of material as was believed to be present following the August 27 flare. Finally, we discuss how these observations further constrain magnetic field reconfiguration models for the large flares of SGRs.

Woods, P. M.