Engineering Papers⌕ Search

Engineering topics

Woodgate, B. E.

Publications and source records attributed to Woodgate, B. E..

At least 55 records · Page 3

Absolute S- and P-plane polarization efficiencies for high frequency holographic gratings in the VUV

High frequency plane gratings (3500 and 3600 gr/mm) have been holographically ruled and blazed for the VUV spectral region. All gratings were coated with 70 nm Al + 25 nm MgF2. Absolute unpolarized and S- and P-plane polarization efficiencies have been measured for the first and second orders in the 120- to 450-nm spectral region at 18.5 and 30 deg angles of deviation. For deep grooves, anomalous features are more pronounced for the P-plane polarization efficiency than for the S-plane polarization efficiency. Holographic gratings can be tailored to produce high polarization or low polarization in the VUV. For comparison, efficiencies and polarization of the best conventional high frequency gratings were also determined. Measurements show that scattered light is significantly lower for holographic gratings in the VUV when compared with the conventional gratings.

Caruso, A. J.↗

Observations of the 1980 April 30 limb flare by the ultraviolet spectrometer and polarimeter on the Solar Maximum Mission

Observations of the M2 limb flare of 1980 April 30 by the ultraviolet spectrometer and polarimeter in the C IV 1548 A line are described and compared with observations from other SMM instruments and with ground-based H-alpha data. Events observed during the 18 minutes leading up to the flare impulsive phase include the filling of a small loop with material moving at about 20 km/s, followed by a rapid brightening in C IV, H-alpha, and hard X-rays, with a subsequent brightening of a higher set of loops. The rapid brightening appears to be at the junction of the small loop with the overlying magnetic structures, which suggests the flare may be caused by their interaction.

Woodgate, B. E.↗

Performance and design of the ultraviolet spectrometer and polarimeter on the solar maximum mission

The instrument observes spectral line intensity, Doppler motions, and polarization parameters. First Dopplergrams of the sun showing mass motion of prominences have been obtained. The instrument consists of a telescope, a spectrometer, a polarimeter, and five detectors. Spectral range extends from 1150 to 3600 Angstroms. The telescope is an alphanatic Gregorian capable of scanning a 256 x 256 arcsecond raster. The spectrometer is an Ebert-Fastie mount with exchangeable slits for intensity measurements and spectroscopy. Detectors are photomultipliers operating in the pulse-counting mode.

Sterk, A. A.↗

Solar Maximum Mission Experiment - Ultraviolet Spectroscopy and Polarimetry on the Solar Maximum Mission

The Ultraviolet Spectrometer and Polarimeter on the Solar Maximum Mission spacecraft is described. It is pointed out that the instrument, which operates in the wavelength range 1150-3600 A, has a spatial resolution of 2-3 arcsec and a spectral resolution of 0.02 A FWHM in second order. A Gregorian telescope, with a focal length of 1.8 m, feeds a 1 m Ebert-Fastie spectrometer. A polarimeter comprising rotating Mg F2 waveplates can be inserted behind the spectrometer entrance slit; it permits all four Stokes parameters to be determined. Among the observing modes are rasters, spectral scans, velocity measurements, and polarimetry. Examples of initial observations made since launch are presented.

Tandberg-Hanssen, E.↗

UVSP/SMM observations of transition region oscillations in sunspots

Using Ultraviolet Spectrometer and Polarimeter data obtained in emission lines formed at temperatures of 70,000 K to 130,000 K, transition region oscillations in sunspots have been observed. The frequency of these oscillations lies in the range 5.8 mHz to 7.8 mHz. Their regular appearance in line-of-sight velocity and their frequent occurrence in intensity in phase with maximum blue shift leads to the interpretation of the oscillations as upward-propagating acoustic waves. The presence in two of the C IV wavelength 1548.19 time series of a phase-shifted oscillation in the line width may be caused by the presence of unidentified blends in the line wings. The energy flux carried by the umbral acoustic waves is less than 2000 erg/sq cm/s, some seven orders of magnitude smaller than the missing radiative flux of sunspots.

Gurman, J. B.↗

The Ultraviolet Spectrometer and Polarimeter on the Solar Maximum Mission

The Ultraviolet Spectrometer and Polarimeter (UVSP) on the Solar Maximum Mission spacecraft is described, including the experiment objectives, system design, performance, and modes of operation. The instrument operates in the wavelength range 1150-3600 A with better than 2 arcsec spatial resolution, raster range 256 x 256 sq arcsec, and 20 mA spectral resolution in second order. Observations can be made with specific sets of four lines simultaneously, or with both sides of two lines simultaneously for velocity and polarization. A rotatable retarder can be inserted into the spectrometer beam for measurement of Zeeman splitting and linear polarization in the transition region and chromosphere.

Woodgate, B. E.↗

Method and apparatus for slicing crystals

The crystal slicing method is described as follows. A crystal is sliced in a plane parallel to flat, opposed parallel end faces of the crystal. The end faces of the crystal are gripped by a pair of opposed, perforated platens of a pair of vacuum chambers, one of which is translatable relative to the other. A blade cuts the crystal through the desired plane. A spring biases one of the vacuum chambers away from the other vacuum chamber while both of the faces are gripped by the vacuum chambers and the blade is cleaving the crystal. A sliced portion of the crystal gripped by one of the vacuum chambers is pulled away from the remainder of the crystal gripped by the second vacuum chamber when the crystal was cleaved by the blade through the plane.

Benedicto, J. S. J.↗

Forbidden Fe X and forbidden Fe XIV emission from Puppis A and other supernova remnants

Measurements of Fe XIV 5303-A and Fe X 6374-A forbidden emission from several supernova remnants are reported, and their relation to X-ray observations is discussed. The brightest Fe XIV forbidden-emission region in Puppis A is interpreted as being the result of the supernova shock wave's interacting with a dense cloud in the interstellar medium.

Lucke, R. L.↗

Precision cleaver for "soft" crystals

"Soft" crystals are cleaved as thin 0.005 inch with special cleaver. Thin slices of soft crystalline materials are used in X-ray spectrometers. Slices are usually cut by hand with wire or blade. Wire tends to scratch surface and to produce slices of nonuniform thickness. Device will rapidly cut soft crystals in smooth, thin, uniform slices.

Benedicto, J. S. J.↗

Some recent coronal line observations of supernova remnants

Observations of optical coronal lines from the supernova remnants Puppis A and N 49 in the Large Magellanic Cloud carried out at Cerro Tololo and the Anglo-Australian Observatory are reported. The eastern section of Puppis A was searched for forbidden Fe X and Fe XIV emissions in order to confirm the previous detection of a lower temperature component of the X-ray source. Strong forbidden Fe XIV emission was detected in one region consistent with the position of the previously observed soft X-ray component, implying a cool localized component, possibly a relatively dense interstellar cloud interacting with the expanding shock front, superimposed on a more extended hotter region. The spectrum of N 49 showed a broad feature at 5303 A, identified with the forbidden Fe XIV line. Predictions of X-ray fluxes assuming a temperature of 2 x 10 to the 6th K and a density behind the shock front of 4/cu cm for hydrogen densities of zero and 10 to the 21st/sq cm lead to the suggestion that X-ray observations of N 49 may prove worthwhile.

Zarnecki, J. C.↗

Solar maximum ultraviolet spectrometer and polarimeter

The objectives of the UVSP experiment are to study solar ultraviolet radiations, particularly from flares and active regions, and to measure constituents in the terrestrial atmosphere by the extinction of sunlight at satellite dawn and dusk. The instrument is designed to observe the Sun at a variety of spectral and spatial resolutions in the range from 1150 to 3600 A. A Gregorian telescope with effective focal length of 1.8 m is used to feed a 1 m Ebert-Fastie spectrometer. A polarimeter containing rotatable magnesium fluoride waveplates is included behind the spectrometer entrance slit and will allow all four Stokes parameters to be determined. Velocities on the Sun can also be measured. The instrument is controlled by a computer which can interact with the data stream to modify the observing program. The observing modes, including rasters, spectral scans, velocity measurements, and polarimetry, are also described along with plans for mission operations, data handling, and analysis of the observations.

Tandberg-Hanssen, E.↗

Radial distribution of Fe XIV emission in the Cygnus Loop

The one dimensional distribution of Fe 14 emission has been determined along a radius of the Cygnus Loop through the use of a tilting filter photometer. The observed emission extends at least 5 arc minutes outside the optical filaments. A simple Sedov solution model of the temperature and density distribution behind the shock agrees with the observations if the shock front is near the extent of the Fe 14 emission, the shock velocity is from 300 to 250/kms and the density external to the remnant is about 0.7-1.4 cm to three minus 3 power. These parameters are in reasonable agreement with X-ray maps and optical radial velocities.

Woodgate, B. E.↗

A focussing iron line crystal spectrometer for Spacelab

A crystal spectrometer system is described which employs conical focusing of 12 curved LiF crystal panels to minimize the detector size and reduce the background counting rate. The wavelength range from 1.70 to 1.98 A is covered, including the resonance lines of Fe XXV and Fe XXVI as well as the Fe I K-alpha line and absorption edge. Operation of the spectrometer is discussed, noting that diffracted X-rays are registered in one-dimensional position-sensitive detectors and that the arrival position of a photon in a detector is related to its wavelength due to the fixed curvature of the crystal panels in the dispersion plane. Some characteristics of the multianode position-sensitive detectors are reviewed along with the crystal arrangement and mounting. The instrument sensitivity is evaluated in relation to the strengths of 6.7-keV emission features detected by the Ariel 5 and OSO 8 proportional-counter spectrometers.

Catura, R. C.↗

Pinhole diffraction filter

Multistage diffraction filter consisting of coalined series of pinholes on parallel sheets can be used as nondegradable UV filter. Beam is attenuated as each pinhole diffracts radiation in controlled manner into divergent beam, and following pinhole accepts only small part of that beam.

Woodgate, B. E.↗

Shadow mask for X-ray spectrometer

Imaging technique may be used in series with flat or conical Bragg crystals to separate spatial/spectral convolution when spectrometer is scanned across extended source emitting at more than one wavelength. Technique allows line direction and continuum to be detected and provides data for spatial mapping of source.

Woodgate, B. E.↗

A large-area lithium-fluoride Bragg spectrometer for stellar X-ray astronomy

A large-area Bragg spectrometer used to search for the Fe XXV X-ray emission lines of Sco X-1 is described. The device has 3400 sq cm of LiF on nine crystal panels aligned perpendicular to the longitudinal axis of the rocket. X rays satisfying the Bragg condition reflect into an array of nine companion proportional counters. A pointing system incorporating a free gyroscope with 2 degrees of freedom assures that target X rays are reflected at the required angle and produces repeated spectral scans of the X-ray continuum, which are later superimposed to correct temporal effects. The instrument is capable of detecting a narrow line flux from Sco X-1 of about .01 photons/sq cm/sec.

Stockman, H. S., Jr.↗