Engineering PapersSearch

Engineering topics

Wood, G. M.

Publications and source records attributed to Wood, G. M..

Recent advances in efficient long-life, eye-safe solid state and CO2 lasers for laser radar applications

The key problems in the development of eye-safe solid-state lasers are discussed, taking into account the energy transfer mechanisms between the complicated energy level manifolds of the Tm, Ho, Er ion dopants in hosts with decreasing crystal fields such as YAG or YLF. Optimization of energy transfer for efficient lasing through choice of dopant concentration, power density, crystal field and temperature is addressed. The tailoring of energy transfer times to provide efficient energy extraction for short pulses used in DIAL and Doppler lidar is considered. Recent advances in Pt/SnO2 oxide catalysts and other noble metal/metal oxide combinations for CO2 lasers are discussed. Emphasis is given to the dramatic effects of small quantities of H2O vapor for increasing the activity and lifetime of Pt/SnO2 catalysts and to increased lifetime operation with rare isotope (C-12)(O-18)2 lasing mixtures.

Hess, R. V.

Characterization of Pt/SnO2 catalysts for CO oxidation

Results are presented of surface characterization of 2% and 1% (w/w) Pt on SnO2 catalysts which are being used in promoting the oxidation of CO in pulsed CO2 lasers. The N2 adsorption BET surface area for both catalysts is 6.9 sq m/g. The CO chemisorbed area at 313K is 0.17 sq m/g and 0.062 sq m/g for the 2% and 1% catalysts, respectively. Monitoring the reaction between CO and O2 by the same technique, at the same temperature yields a turn-over frequency (TOF) for the 2% catalyst of 2.7 x 100 molecules of CO2/site/s and for the 1% catalyst a value of 1.2 x 100. The ratio of the TOFs for the two catalysts is 2.2 which is approximately the ratio of the Pt loading.

Brown, K. G.

Shuttle Continuous Open Wind Tunnel (SCOWT)

The aerodynamic and heat transfer coefficients are studied within the range of thermo-fluid-dynamic conditions experienced by a satellite during Tethered Satellite System (TSS) atmospheric flights. The gasdynamic processes occuring downstream of the bow wave standing in front of the satellite are also studied. The knowledge of the chemistry and physics of the upper atmosphere related to satellite aerothermodynamics is furthered. The existence of an overshooting of the air drag coefficient of the sphere in the transition regime is validated. A complete set of measurements is performed in order to provide the data base to develop and validate theoretical models of free molecule transition flow fields.

Carlomagno, G. M.

Shuttle Tethered Aerothermodynamics Research Facility (STARFAC)

The Earth's atmosphere from 90 km to 200 km provides the last aerothermodynamics frontier. Present NASA programs which require but also can provide an understanding of the aerodynamics and aerothermodynamics of the free molecule and transition flows that exist at these altitudes are the Aeroassisted OTV, Entry Research Vehicle and the Tethered Satellite. Each of these programs provides a unique opportunity to do flight research in the rarefied upper atmosphere. However, the Tethered Satellite Program provides, because of its capability to obtain global, in-situ, steady state data, the greatest potential to: (1)define the performance of aerodynamic shapes as a function of environmental characteristics (free molecule, transition, slip flow regimes); (2)define the characteristics of the upper atmosphere and the global variability of properties such as composition temperature, pressure and density. Such data are required to accomplish the systematic development and verification of analytical prediction techniques required to support advance configuration designs.

Siemers, P. M.

Optimization of the catalytic oxidation of CO for closed-cycle CO2 laser applications

This report develops a basis for the design of a catalyst bed for the recombination of CO and O2 in a closed-cycle CO2 laser system. The catalyst is 1% Pt on SnO2 having a BET surface area of 6.7 sq m/g and a specific void volume of 0.374 cu cm/g. The design conditions are: a catalyst bed temperature of 100 C and a circulating flow rate of 10 lambda/min. Under these conditions, the required quantity of catalyst for prolonged laser operation of 668g. The rat law for the reaction of a stoichiometric mixture of 1% CO + 1/2% O2 in helium was determined to be overall first order; however, additional experiments with non-stoichiometric gas mixtures of CO and O2 are needed to determine the order of the CO concentration and the order of the O2 concentration in the rate law.

Miller, I. M.

Instrumentation for Application Number 1: Mass Spectrometric Analysis of the Boundary Layer Associated with the Tethered Satellite

Knowledge about the boundary layer associated with high enthalpy flow fields has mostly been derived from measurements of physical properties. To further this understanding, the chemistry of the gaseous layer must be studied as well. This requires that instrumentation and measurement methods be developed that can analyze the gases while having a minimal effect on the flow field and composition. Because of its sensitivity and ability to identify species, the mass spectrometer is the most promising instrument for this application, although other spectroscopic methods are being evaluated as well. There are, however, several non-trivial problems that must be solved in order to apply the mass spectrometer, including the obtaining of a representative sample from near the model surface. These problems are being addressed in a research program to develop qualitative and quantitative measurement methods to examine the gas chemistry in several large hot-gas blowdown facilities, and to study the aerodynamics of the boundary layer associated with models in these facilities and in instrumented hypersonic vehicles. These methods can also be applied to the tethered satellite, which will provide a unique opportunity to obtain aerothermodynamic data that is unaltered by effects from the test facility.

Wood, G. M.

Non-catalytic surfaces for metallic heat shields

The magnitude of the atom recombination coefficients needed for metal heat shield surfaces on Shuttle-type vehicles is analyzed and discussed. Prior work which identifies surfaces having low catalytic activity is reviewed. Arc tunnel tests to evaluate catalytic activity are described and the difficulties of such tests are discussed. Results are presented which show major differences between atom recombination and atom exchange from molecules. Results of surface analysis show that bulk and surface composition of a coating are different.

Swann, R. T.

Low energy electron magnetometer using a monoenergetic electron beam

A low energy electron beam magnetometer utilizes near-monoenergetic electrons thereby reducing errors due to electron energy spread and electron nonuniform angular distribution. In a first embodiment, atoms in an atomic beam of an inert gas are excited to a Rydberg state and then electrons of near zero energy are detached from the Rydberg atoms. The near zero energy electrons are then accelerated by an electric field V(acc) to form the electron beam. In a second embodiment, a filament emits electrons into an electrostatic analyzer which selects electrons at a predetermined energy level within a very narrow range. These selected electrons make up the electron beam that is subjected to the magnetic field being measured.

Singh, J. J.

Data enhancement and analysis through mathematical deconvolution of signals from scientific measuring instruments

Mathematical deconvolution of digitized analog signals from scientific measuring instruments is shown to be a means of extracting important information which is otherwise hidden due to time-constant and other broadening or distortion effects caused by the experiment. Three different approaches to deconvolution and their subsequent application to recorded data from three analytical instruments are considered. To demonstrate the efficacy of deconvolution, the use of these approaches to solve the convolution integral for the gas chromatograph, magnetic mass spectrometer, and the time-of-flight mass spectrometer are described. Other possible applications of these types of numerical treatment of data to yield superior results from analog signals of the physical parameters normally measured in aerospace simulation facilities are suggested and briefly discussed.

Wood, G. M.

A feasibility study of ion implantation techniques for mass spectrometer calibration

An experimental study was undertaken to examine the feasibility of using ion-implanted filaments doped with either an alkali metal or noble gas for in situ recalibration of onboard mass spectrometers during extended space missions. Implants of rubidium and krypton in rhenium ribbon filaments were subsequently tested in a bakeable 60 deg sector mass spectrometer operating in the static mode. Surface ionization and electron impact ion sources were both used, each yielding satisfactory results. The metallic implant with subsequent ionization provided a means of mass scale calibration and determination of system operating parameters, whereas the noble gas thermally desorbed into the system was more suited for partial pressure and sensitivity determinations.

Koslin, M. E.

On-line mass spectrometric monitoring of the polymerization of a phenolic-resin-based material

Polymerization of phenolic-resin-based materials requires elevated temperatures. The low thermal conductivity of these materials has led to the use of dielectric heating techniques in lieu of standard convection oven heating to obtain a satisfactory cure. The curing rate and therefore the quality of the cured material depends on the heating rate and maximum temperature attained, parameters which are extremely difficult to measure in dielectric heating units. The dielectric curing of these materials was monitored by using a mass spectrometer to measure the partial pressure of phenol in the gas evolved during polymerization. The resulting plots of phenol partial pressure as a function of time have a characteristic shape, and these may be used to indicate the attainment of complete curing. The validity of the mass spectrometric technique was confirmed by chemical analysis of the polymerized samples.

Aikens, D. A.

Determination of water content using mass spectrometry

Mass spectrometer is used to measure small quantities of water present in different materials. System has been applied in measuring water and gases desorbed from microcircuitry insulation, can also be used with foods, polymeric materials, and organic solvents.

Wood, G. M.

Dynamic delta method for trace gas analysis

Method has been developed in which measurements are made only over viscous flow range, eliminating fractionation before the molecular leak and problems due to surface elution.

Wood, G. M.

Rapid helium-air analyzer can measure other binary gas mixtures

Instrument comprised of an ionization pressure gage and a diaphragm pressure gage consisting of strain gages to make a four-arm bridge, and a ratiometer is constructed for analyzing gas mixtures. The ratio of the outputs of the two gages is proportional to the mixture composition.

Melfi, L. T.