Engineering Papers⌕ Search

Engineering topics

Wong, J.

Publications and source records attributed to Wong, J..

At least 19 records

BASS. XXXVI. Constraining the Local Supermassive Black Hole–Halo Connection with BASS DR2 AGNs

We investigate the connection between supermassive black holes (SMBHs) and their host dark matter halos in the local universe using the clustering statistics and luminosity function of active galactic nuclei (AGNs) from the Swift/BAT AGN Spectroscopic Survey (BASS DR2). By forward-modeling AGN activity into snapshot halo catalogs from N -body simulations, we test a scenario in which SMBH mass correlates with dark matter (sub)halo mass for fixed stellar mass. We compare this to a model absent of this correlation, where stellar mass alone determines the SMBH mass. We find that while both simple models are able to largely reproduce the abundance and overall clustering of AGNs, the model in which black hole mass is tightly correlated with halo mass is preferred by the data by 1.8 σ . When including an independent measurement on the black hole mass–halo mass correlation, this model is preferred by 4.6 σ . We show that the clustering trends with black hole mass can further break the degeneracies between the two scenarios and that our preferred model reproduces the measured clustering differences on one-halo scales between large and small black hole masses. These results indicate that the halo binding energy is fundamentally connected to the growth of SMBHs.

79 ASTRONOMY AND ASTROPHYSICS↗

Radial Spin Texture of the Weyl Fermions in Chiral Tellurium

Trigonal tellurium, a small-gap semiconductor with pronounced magneto-electric and magneto-optical responses, is among the simplest realizations of a chiral crystal. We have studied by spin- and angle-resolved photoelectron spectroscopy its unconventional electronic structure and unique spin texture. We identify Kramers-Weyl, composite, and accordionlike Weyl fermions, so far only predicted by theory, and show that the spin polarization is parallel to the wave vector along the lines in k space connecting high-symmetry points. Our results clarify the symmetries that enforce such spin texture in a chiral crystal, thus bringing new insight in the formation of a spin vectorial field more complex than the previously proposed hedgehog configuration. Our findings thus pave the way to a classification scheme for these exotic spin textures and their search in chiral crystals.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reorientation-effect measurement of the first 2 + state in 12 C: Confirmation of oblate deformation

A Coulomb-excitation reorientation-effect measurement using the TIGRESS γ-ray spectrometer at the TRIUMF/ISAC II facility has permitted the determination of the $\langle$2$^+_1$ || $\hat{E2}$ || $2^+_1$$\rangle$ diagonal matrix element in 12 C from particle-γ coincidence data and state-of-the-art no-core shell model calculations of the nuclear polarizability. The nuclear polarizability for the ground and first-excited (2$^+_1$) states in 12 C have been calculated using chiral NN N 4 LO500 and NN+3NF350 interactions, which show convergence and agreement with photo-absorption cross-section data. Predictions show a change in the nuclear polarizability with a substantial increase between the ground state and first excited 2$^+_1$ state at 4.439 MeV. The polarizability of the 2$^+_1$ state is introduced into the current and previous Coulomb-excitation reorientation-effect analyses of 12 C. Spectroscopic quadrupole moments of $Q_S$(2$^+_1$) =+0.053(44) eb and $Q_S$(2$^+_1$) =+0.08(3) are determined, respectively, yielding a weighted average of $Q_S$(2$^+_1$)=+0.071(25) eb, in agreement with recent ab initio calculations. The present measurement confirms that the 2$^+_1$ state of 12 C is oblate and emphasizes the important role played by the nuclear polarizability in Coulomb-excitation studies of light nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Prototype Stilbene Neutron Collar

A neutron collar using stilbene organic scintillator cells for fast neutron counting is described for the assay of fresh low enriched uranium (LEU) fuel assemblies. The prototype stilbene collar has a form factor similar to standard He-3 based collars and uses an AmLi interrogation neutron source. This report describes the simulation of list mode neutron correlation data on various fuel assemblies including some with neutron absorbers (burnable Gd poisons). Calibration curves (doubles vs 235 U linear mass density) are presented for both thermal and fast (with Cd lining) modes of operation. It is shown that the stilbene collar meets or exceeds the current capabilities of He-3 based neutron collars. A self-consistent assay methodology, uniquely suited to the stilbene collar, using triples is described which complements traditional assay based on doubles calibration curves.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

MO-FG-213-04: Managing the Relationship

Academic-industrial collaborations are playing an increasingly prominent role in medical physics research. Successful partnerships have enabled truly translational, benchtop-to-bedside research that has significantly and positively impacted our field. Given the current flat or depleting trends in federal funding, and the increasing emphasis in the medical physics community on demonstrating translatability, efficacy, and safety prior to widespread clinical use, it is anticipated that such partnerships will become ever more important in advancing our field. In the future, it is likely that neither academia alone, nor industry alone, will be able to bring significant innovation to successfully impact patient care in radiotherapy. Such innovation will require partnership and symbiosis through the lifetime of the project. This symposium is aimed at professionals from academia and the industry who are interested in either initiating new collaborations or maintaining and improving existing partnerships. We will hear from four thought leaders from industry and academia on critical aspects of building and maintaining successful academic-industrial research partnerships. The following topics will be addressed: 1. Motivations: The industry perspective [Kevin Brown, Elekta] What goes into the development of a company’s R&D roadmap What are the motivations and expectations of the industry from academic partners How can academics make a successful pitch by identifying projects aligned with a company’s roadmap Why are some relationships successful and some not Milestones and progress reports - Why do we need them 2. Motivations: The academic perspective [T. Rock Mackie, Univ. of Madison, WI; Tomotherapy] What are the motivations and expectations of academic partners from the industry What are the cultural differences in academia vs industry on sharing information, exchanging ideas Partnership or entrepreneurship? When does each option make sense 3. Industrial Grants and Research Contracts – a Primer [Norbert Pelc; Stanford University] What topics are suited to industrial grants vs. academic grants How do resources (personnel effort, tuition) get allocated and charged in academia What are reasonable resource and timeline requests for small and big projects; from small and big companies “Fair market value” considerations Sections of a research agreement (IP including software confidential information, publications, data, exclusivity, support) 4. Managing the relationship [John Wong, Johns Hopkins University] How to effectively collaborate with each other How to adapt to changes in the relationship How to renew funding with the industry Moderated Panel Discussion [All speakers + moderators] Learning Objectives: 1. Understand the motivations of each partner 2. Elements that contribute to a successful partnership 3. Avoiding pitfalls - Challenges on either side that may derail a project 4. How to frame a research grant and agreement 5. How to sustain the collaborative relationship Amit Sawant: Funding from: NIH. Varian, Elekta and VisionRT; Michelle Svatos: Employee and shareholder: Varian, Board Member, TopasMC; Kevin Brown: Employee, Elekta; T. Rock Mackie: Consultant, Accuray; Norbert Pelc: Research support: Philips Healthcare, GE Healthcare; John Wong: Funding from NIH, Xstrahl and Elekta. Co-founder and advisor for JPLC Associates, LLC.

07 ISOTOPE AND RADIATION SOURCES↗

Ground-state and pairing-vibrational bands with equal quadrupole collectivity in 124 Xe

The nuclear structure of 124 Xe has been investigated via measurements of the β + /EC decay of 124 Cs with the 8π γ-ray spectrometer at the TRIUMF-ISAC facility. The data collected have enabled branching ratio measurements of weak, low-energy transitions from highly excited states, and the 2 + → 0 + in-band transitions have been observed. Combining these results with those from a previous Coulomb excitation study, $B(E2; 2^+_3 → 0^+_2)$ = 78(13) W.u. and $B(E2; 2^+_4 → 0^+_3)$ = 53(12) W.u. were determined. The $0^+_3$ state, in particular, is interpreted as the main fragment of the proton-pairing vibrational band identified in a previous 122 Te( 3 He,n) 124 Xe measurement, and has quadrupole collectivity equal to, within uncertainty, that of the ground-state band.

74 ATOMIC AND MOLECULAR PHYSICS↗

Far From 'Easy' Spectroscopy with the 8 pi and GRIFFIN Spectrometers at TRIUMF-ISAC

The 8 pi spectrometer, installed at the TRIUMF-ISAC facility, was the world's most sensitive gamma-ray spectrometer dedicated to beta-decay studies. A description is given of the 8 pi spectrometer and its auxiliary detectors including the plastic scintillator array SCEPTAR used for beta-particle tagging and the Si(Li) array PACES for conversion electron measurements, its moving tape collector, and its data acquisition system. The recent investigation of the decay of Cs-124 to study the nuclear structure of Xe-124, and how the beta-decay measurements complemented previous Coulomb excitation studies, is highlighted, including the extraction of the deformation parameters for the excited 0(+) bands in Xe-124. As a by-product, the decay scheme of the (7(+)) Cs-124 isomeric state, for which the data from the PACES detectors were vital, was studied. Finally, a description of the new GRIFFIN spectrometer, which uses the same auxiliary detectors as the 8 pi spectrometer, is given.

Garrett, Paul↗

Direct observation of bi-alkali antimonide photocathodes growth via in operando x-ray diffraction studies

Alkali antimonides have a long history as visible-light-sensitive photocathodes. This work focuses on the process of fabrication of the bi-alkali photocathodes, K{sub 2}CsSb. In-situ synchrotron x-ray diffraction and photoresponse measurements were used to monitor phase evolution during sequential photocathode growth mode on Si(100) substrates. The amorphous-to-crystalline transition for the initial antimony layer was observed at a film thickness of 40 Å . The antimony crystalline structure dissolved upon potassium deposition, eventually recrystallizing upon further deposition into K-Sb crystalline modifications. This transition, as well as the conversion of potassium antimonide to K{sub 2}CsSb upon cesium deposition, is correlated with changes in the quantum efficiency.

36 MATERIALS SCIENCE↗

Localization of needle tip with color doppler during pericardiocentesis: In vitro validation and initial clinical application

This study evaluates a new device that uses color Doppler ultrasonography to enable real-time image guidance of the aspirating needle, which has not been possible until now. The ColorMark device (EchoCath Inc, Princeton, NJ) induces high-frequency, low-amplitude vibrations in the needle to enable localization with color Doppler. We studied this technique in 25 consecutive patients undergoing pericardiocentesis, and in vitro, in a urethane phantom with which the accuracy of color Doppler localization of the needle tip was compared with that obtained by direct measurement. Tip localization was excellent in vitro; errors axial to the ultrasound beam (velocity Doppler -0.13 +/- 0.90 mm, power Doppler -0.05 +/- 1.7 mm) were less than lateral errors (velocity -0.36 +/- 1.8 mm, power -0.02 +/- 2.8 mm). In 18 of 25 patients, the needle was identified and guided into the pericardial space with the ColorMark technique, and it allowed successful, uncomplicated drainage of fluid. Initial failures were the result of incorrect settings on the echocardiographic machine and inappropriate combinations of the needle puncture site and imaging window. This study demonstrates a novel color Doppler technique that is highly accurate at localizing a needle tip. The technique is feasible for guiding pericardiocentesis. Further clinical validation of this technique is required.

NASA Discipline Cardiopulmonary↗