Engineering Papers⌕ Search

Engineering topics

Wollman, Emma E.

Publications and source records attributed to Wollman, Emma E..

Large active-area superconducting microwire detector array with single-photon sensitivity in the near-infrared

Superconducting nanowire single photon detectors (SNSPDs) are the highest-performing technology for time-resolved single-photon counting from the UV to the near-infrared. The recent discovery of single-photon sensitivity in micrometer-scale superconducting wires is a promising pathway to explore for large active area devices with application to dark matter searches and fundamental physics experiments. We present 8-pixel $1 mm^2$ superconducting microwire single photon detectors (SMSPDs) with $1\,\mathrm{\mu m}$-wide wires fabricated from WSi and MoSi films of various stoichiometries using electron-beam and optical lithography. Devices made from all materials and fabrication techniques show saturated internal detection efficiency at 1064 nm in at least one pixel, and the best performing device made from silicon-rich WSi shows single-photon sensitivity in all 8 pixels and saturated internal detection efficiency in 6/8 pixels. This detector is the largest reported active-area SMSPD or SNSPD with near-IR sensitivity published to date, and the first report of an SMSPD array. By further optimizing the photolithography techniques presented in this work, a viable pathway exists to realize larger devices with $cm^2$-scale active area and beyond.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Picosecond Synchronization System for the Distribution of Photon Pairs Through a Fiber Link Between Fermilab and Argonne National Laboratories

Here we demonstrate a three-node quantum network for C-band photon pairs using 2 pairs of 59 km of deployed fiber between Fermi and Argonne National Laboratories. The C-band pairs are directed to nodes using a standard telecommunication switch and the detection system is synchronized to picosecond scale timing resolution using a coexisting O-or L-band optical clock distribution system. We measure a reduction of coincidence to-accidental ratio (CAR) of the C-band pairs from 51 ± 2 to 5.3 ± 0.4 due to Raman scattering of the O-band clock pulses. Despite this reduction, the CAR is nevertheless suitable for quantum networks.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time-walk and jitter correction in SNSPDs at high count rates

Superconducting nanowire single-photon detectors (SNSPDs) are a leading detector type for time correlated single photon counting, especially in the near-infrared. When operated at high count rates, SNSPDs exhibit increased timing jitter caused by internal device properties and features of the RF amplification chain. Variations in RF pulse height and shape lead to variations in the latency of timing measurements. To compensate for this, we demonstrate a calibration method that correlates delays in detection events with the time elapsed between pulses. The increase in jitter at high rates can be largely canceled in software by applying corrections derived from the calibration process. We demonstrate our method with a single-pixel tungsten silicide SNSPD and show it decreases high count rate jitter. The technique is especially effective at removing a long tail that appears in the instrument response function at high count rates. At a count rate of 11.4 MCounts/s, we reduce the full width at 1% maximum level (FW1%M) by 45%. The method, therefore, enables certain quantum communication protocols that are rate-limited by the FW1%M metric to operate almost twice as fast.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Picosecond Synchronization System for Quantum Networks

The operation of long-distance quantum networks requires photons to be synchronized and must account for length variations of quantum channels. We demonstrate a 200 MHz clock-rate fiber optic-based telecommunication C-band quantum network using off-the-shelf components combined with custom-made electronics. The network is backed by a scalable and fully automated synchronization system with ps-scale timing resolution. Synchronization of the photons is achieved by distributing O-band-wavelength laser pulses between network nodes. Specifically, we distribute photon pairs between three nodes, and measure a reduction of coincidence-to-accidental ratio from 77 to only 42 when the synchronization system is enabled, which permits high-fidelity qubit transmission. Our demonstration sheds light on the role of noise in quantum communication and represents a key step in realizing deployed co-existing classical-quantum networks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗