Engineering PapersSearch

Engineering topics

Wolf, S. W. D.

Publications and source records attributed to Wolf, S. W. D..

The design and operational development of self-streamlining 2-dimensional flexible walled test sections

Self streamlining two dimensional flexible walled test sections eliminate the uncertainties found in data from conventional test sections particularly at transonic speeds. The test section sidewalls are rigid, while the floor and ceiling are flexible and are positioned to streamline shapes by a system of jacks, without reference to the model. The walls are therefore self streamlining. Data are taken from the model when the walls are good streamlines such that the inevitable residual wall induced interference is acceptably small and correctable. Successful two dimensional validation testing at low speeds has led to the development of a new transonic flexible walled test section. Tunnel setting times are minimized by the development of a rapid wall setting strategy coupled with on line computer control of wall shapes using motorized jacks. Two dimensional validation testing using symmetric and cambered aerofoils in the Mach number range up to about 0.85 where the walls are just supercritical, shows good agreement with reference data using small height-chord ratios between 1.5 and unity.

Wolf, S. W. D.

A wake traverse technique for use in a 2 dimensional transonic flexible walled test section

Reported two dimensional validation data from the Transonic Self-Streamlining Wind Tunnel (TSWT) concerns model lift. The models tested provided data on their pressure distributions. This information was numerically integrated over the model surface to determine lift, pressure drag and pitching moment. However, the pressure drag is only a small component of the total drag at nominal angles of attack and cannot be used to assess the quality of flow simulation. An intrusive technique for obtaining information on the total drag of a model in TSWT is described. The technique adopted is the wake traverse method. The associated tunnel hardware and control and data reduction software are outlined and some experimental results are presented for discussion.

Wolf, S. W. D.

The status of two- and three-dimensional testing in the University of Southampton transonic self-streamlining wind tunnel

An automated test section was used to develop a flexible walled testing technique which eliminates some sources of uncertainty in boundary interference effects which exist in conventional transonic test sections. The flexible floor and ceiling of the test section were adjusted to contours which produce a constant Mach number distribution along each wall with no model present. These aerodynamically straight contours form the basis for all streamlining. The wall data are to contain information on the models performance and on lift. Two dimensional validation testing has continued with a cambered NPL 9510 section. Lift data up to Mach 0.87 are compared with reference data. Drag information on a NACA 0012-64 section is presented to indicate the powerful effects of streamlining. Preliminary three dimensional testing in the two dimensional test section has demonstrated that model and support blockage can be relieved by wall contouring.

Wolf, S. W. D.

Selected data from a transonic flexible walled test section

Twenty four test runs of the Transonic Self-Streamlining Wind Tunnel were performed with the flexible walls 'streamlined' around a two dimensional section of four inch chord, over the Mach number range 0.3 to 0.89. Relevant wall and model data for the streamlined cases are presented.

Wolf, S. W. D.

The development of a self-streamlining flexible walled transonic test section

This design eliminates the uncertainties in data from conventional transonic test sections. Sidewalls are rigid, and the flexible floor and ceiling are positioned by motorized jacks controlled by on-line computer to minimize run times. The tunnel-computer combination is self-streamlining without reference to the model. Data is taken from the model only when the walls are good streamlines, and is corrected for the small, known but inevitable residual interferences. Two-dimensional validation testing in the Mach range up to about 0.85 where the walls are just supercritical shows good agreement with reference data using a height:chord ratio of 1.5. Techniques are under development to extend Mach number above 1. This work has demonstrated the feasibility of almost eliminating wall interferences, improving flow quality, and reducing power requirements or increasing Reynolds number. Extensions to three-dimensional testing are outlined.

Goodyer, M. J.

Self streamlining wind tunnel: Further low speed testing and final design studies for the transonic facility

Work was continued with the low speed self streamlining wind tunnel (SSWT) using the NACA 0012-64 airfoil in an effort to explain the discrepancies between the NASA Langley low turbulence pressure tunnel (LTPT) and SSWT results obtained with the airfoil stalled. Conventional wind tunnel corrections were applied to straight wall SSWT airfoil data, to illustrate the inadequacy of standard correction techniques in circumstances of high blockage. Also one SSWT test was re-run at different air speeds to investigate the effects of such changes (perhaps through changes in Reynold's number and freestream turbulence levels) on airfoil data and wall contours. Mechanical design analyses for the transonic self-streamlining wind tunnel (TSWT) were completed by the application of theoretical airfoil flow field data to the elastic beam and streamline analysis. The control system for the transonic facility, which will eventually allow on-line computer operation of the wind tunnel, was outlined.

Wolf, S. W. D.

Studies of self streamlining wind tunnel real and imaginary flows

Testing in the low speed flexible walled tunnel in an effort to explain the reasons for data discrepancies at high angles of attack are presented. Automated transonic test sections were developed. The flexible walled tunnel was used in a new operating mode to a generated curved flow around the airfoil, allowing the extraction of purely rotary derivatives. Some straight wall, low speed pressure data, for wall and model, which is used for checking interference correction methods were reported. Computer software which includes an old streamlining algorithm and a prediction algorithm was examined.

Wolf, S. W. D.

Self streamlining wind tunnel: Further low speed testing and final design studies for the transonic facility

Work has continued with the low speed self streamlining wind tunnel (SSWT) using the NACA 0012-64 airfoil in an effort to explain the discrepancies between the NASA Langley low turbulence pressure tunnel (LTPT) and SSWT results obtained with the airfoil stalled. Conventional wind tunnel corrections were applied to straight wall SSWT airfoil data, to illustrate the inadequacy of standard correction techniques in circumstances of high blockage. Also one SSWT test was re-run at different air speeds to investigate the effects of such changes on airfoil data and wall contours. Mechanical design analyses for the transonic self streamlining wind tunnel (TSWT) were completed by the application of theoretical airfoil flow field data to the elastic beam and streamline analysis. The control system for the transonic facility is outlined.

Wolf, S. W. D.

Self streamlining wind tunnel: Low speed testing and transonic test section design

Comprehensive aerodynamic data on an airfoil section were obtained through a wide range of angles of attack, both stalled and unstalled. Data were gathered using a self streamlining wind tunnel and were compared to results obtained on the same section in a conventional wind tunnel. The reduction of wall interference through streamline was demonstrated.

Wolf, S. W. D.

Analytical Work in Support of the Design and Operation of Two Dimensional Self Streamlining Test Sections

A method has been developed for accurately computing the imaginary flow fields outside a flexible walled test section, applicable to lifting and non-lifting models. The tolerances in the setting of the flexible walls introduce only small levels of aerodynamic interference at the model. While it is not possible to apply corrections for the interference effects, they may be reduced by improving the setting accuracy of the portions of wall immediately above and below the model. Interference effects of the truncation of the length of the streamlined portion of a test section are brought to an acceptably small level by the use of a suitably long test section with the model placed centrally.

Judd, M.