Engineering PapersSearch

Engineering topics

Woeller, F. H.

Publications and source records attributed to Woeller, F. H..

Electrometer Amplifier With Overload Protection

Circuit features low noise, input offset, and high linearity. Input preamplifier includes input-overload protection and nulling circuit to subtract dc offset from output. Prototype dc amplifier designed for use with ion detector has features desirable in general laboratory and field instrumentation.

Woeller, F. H.

Miniature metastable ionization detectors for exobiology flight experiments

The Metastable Ionization Detector (MID) is three orders of magnitude more sensitive than the thermal conductivity detectors used on previous flight instruments. The miniature MID provides scientists with a much smaller and highly sensitive detector for flight gas chromatographs. A miniature MID featuring an unconventional triaxial electrode configuration was developed and used routinely in the laboratory. Although much smaller and lighter than the commercial MID, its performance characteristics parallel those of the traditional design. The detector is compatible with the modulated voltage circuitry, also developed here, and thus can perform over an expanded response range of more than 7 orders magnitude. A micro volume version of a miniature MID, with an internal volume of less than 8 microliter, was recently designed is now being tested. The micro volume MID uses carrier gas flow rates of approx. 2cc/min thus eliminating the need for makeup gas when capillary columns are used.

Woeller, F. H.

A field gas chromatograph using technology developed for solar system exploration

Trace gas analysis is an integral part of biospheric studies. Analytical instruments, primarily gas chromatographs (GC), are capable of measuring gases and volatiles to the ppb-level in real time. Trace gases significant in the study of biocycles include nitrous oxide, hydrogen sulfide, other nitrogen and sulfur species, as well as methane and ethylene. The concept of a field gas chromatograph is derived from technology being pursued in the design of ultra-compact instruments for solar system exploration. The instrument breadboard incorporates the specialized porous column packings and the highly sensitive metastable ionization detector developed by the Solar System Exploration Office. These parts ensure a broad capability for which the analysis of ambient N2O is one example. A commercial, portable gas chromatograph is currently being extensively modified to incorporate analytical concepts and components derived from flight GC technology. Data storage devices suitable for field use are presently being studied.

Woeller, F. H.

Miniature triaxial metastable ionization detector for gas chromatographic trace analysis of extraterrestrial volatiles

The present investigation is concerned with a miniature metastable ionization detector featuring an unconventional electrode configuration, whose performance characteristics parallel those of traditional design. The ionization detector is to be incorporated in a flight gas chromatograph (GC) for use in the Space Shuttle. The design of the detector is discussed, taking into account studies which verified the sensitivity of the detector. The triaxial design of the detector is compared with a flat-plate style. The obtained results show that the principal goal of developing a miniature, highly sensitive ionization detector for flight applications was achieved. Improved fabrication techniques will utilize glass-to-metal seals and brazing procedures.

Woeller, F. H.

A study comparing several isocyanate and isothiocyanate derivatives of Porasil C for the separation of lower hydrocarbons by GC

Several isocyanate and isothiocyanate derivatives of Porasil C were synthesized and evaluated for the separation of the low-molecular-weight saturated and unsaturated hydrocarbons. It was shown that different functional groups significantly affect the retention behavior of the more polar unsaturated hydrocarbons, and that reproducible results can be obtained if dry carrier gas is used.

Pollock, G. E.

A Study Comparing Several Isocyanate and Isothiocyanate Derivatives of Porasil C for the Separation of Lower Hydrocarbons by GC

Several isocyanate and isothiocyanate derivatives Porasil C were synthesized and evaluated for the separation of the low-molecular-weight saturated and unsaturated hydrocarbons. It was shown that different functional groups significantly affect the retention behavior of the more polar unsaturated hydrocarbons, and that reproducible results can be obtained if dry carrier gas is used.

Pollock, Glenn E.

Chelate-modified polymers for atmospheric gas chromatography

Chromatographic materials were developed to serve as the stationary phase of columns used in the separation of atmospheric gases. These materials consist of a crosslinked porous polymer matrix, e.g., a divinylbenzene polymer, into which has been embedded an inorganic complexed ion such as N,N'-ethylene-bis-(acetylacetoniminato)-cobalt (2). Organic nitrogenous bases, such as pyridine, may be incorporated into the chelate polymer complexes to increase their chromatographic utility. With such materials, the process of gas chromatography is greatly simplified, especially in terms of time and quantity of material needed for a gas separation.

Christensen, W. W.

Modified polymers for gas chromatography

Polymeric materials are modified to serve as stationary phase in chromatographic columns used for separation of atmospheric gases. Materials simplify and improve separation of atmospheric gases in terms of time, quantity of material needed, and sharpness of separation.

Woeller, F. H.

Porous bead packings for gas chromatography

Porous polyaromatic packing beads have low polarity, high efficiency, short retention time, and may be synthesized in size range of 50 to 150 micrometers (100 to 270 mesh). Mechanically strong beads may be produced using various materials depending on elements and compounds to be identified.

Pollock, G. E.

Synthesis of porous polyaromatic column packings for GC analysis of extraterrestrial atmospheres

The preparation of a polymer for the Pioneer-Venus Large Probe Gas Chromatograph and another polymer for gas-chromatographic analysis of the Jovian atmosphere is described. Technical-grade divinylbenzene is used as a reliable and economical source of monomer for the preparation of polymer beads. The discussion covers monomeric preparation, polymerization apparatus, first-stage polymer beads, second-stage polymer beads, amino-polymer, columns and gas-chromatographic testing instrumentation used. The polymer for the Pioneer-Venus gas chromatograph is also suitable for ammonia but not for amine analysis. However, the polymer for the analysis of the Jovian atmosphere is a chemically derivatized aromatic polymer that is suitable for amine analysis. The two-stage polymerization produces a highly efficient polymer packing clearly superior to others prepared by adjusted dilution of the aqueous-organic suspension system.

Woeller, F. H.

Test evaluation of potential heat shield contamination of an Outer Planet Probe's atmospheric sampling system

An Outer Planets Probe which retains the charred heatshield during atmospheric descent must deploy a sampling tube through the heatshield to extract atmospheric samples for analysis. Once the sampling tube is deployed, the atmospheric samples ingested must be free of contaminant gases generated by the heatshield. Outgassing products such as methane and water vapor are present in planetary atmospheres and hence, ingestion of such species would result in gas analyzer measurement uncertainties. This paper evaluates the potential for, and design impact of, the extracted atmospheric samples being contaminated by heatshield outgassing products. Flight trajectory data for Jupiter, Saturn and Uranus entries are analyzed to define the conditions resulting in the greatest potential for outgassing products being ingested into the probe's sampling system. An experimental program is defined and described which simulates the key flow field features for a planetary flight in a ground-based test facility. The primary parameters varied in the test include: sampling tube length, injectant mass flow rate and angle of attack. Measured contaminant levels predict the critical sampling tube length for contamination avoidance. Thus, the study demonstrates the compatibility of a retained heatshield concept and high quality atmospheric trace species measurements.

Kessler, W. C.

"Dry-column" chromatography of plant pigments

Separation of plant pigments which can be accomplished on thin-layer silica plates with mixture of petroleum ether, halocarbon, acetone, and polar solvent can be readily translated into dry-column technique that yields reproducible chromatograms after elution in fashion of liquid chromatography with fluorimeter as detector. Best solvent system was found to be mixture of petroleum ether, dichloromethane, acetone, and ethyl acetate.

Woeller, F. H.

Biological effects of fuel and exhaust components from spacecraft descent engines employing hydrazine

The effect of the products of the Viking terminal descent engine fuel upon possible extraterrestrial life at the Martian landing site is examined. The effects of the engine exhaust, the hydrazine fuel, and the breakdown products of the latter on terrestrial microorganisms have been studied. The results indicate that the gaseous exhaust products would probably not be hazardous to microorganisms, but that liquid hydrazine would be lethal.

Lehwalt, M. E.