Engineering PapersSearch

Engineering topics

Witteborn, F. C.

Publications and source records attributed to Witteborn, F. C..

At least 73 records · Page 4

A cryogenically cooled, multidetector spectrometer for infrared astronomy

A liquid helium-cooled, 24 detector grating spectrometer was developed and used for low resolution astronomical observations in the 5 to 14 micron spectral range. The instrument operated on the 91 cm Kuiper Airborne Observatory, the 3 m IRTF (Mauna Kea), the 3 m Shane telescope (Lick Observatory), and the 152 cm NASA and University of Arizona telescope. The detectors are discrete Si:Bi photoconductors with individual metal oxide semiconductor field effect transistor preamplifiers operating at 4 K. The system uses a liquid helium-cooled slit, order-sorter filter, collimator mirror, grating, and camera mirror arranged in a Czerny-Turner configuration with a cold stop added between the collimator mirror and the grating. The distances between components are chosen so that the collimator mirror images the secondary mirror of the telescope onto the cold stop, thus providing a very effective baffle. Scattered radiation is effectively reduced by using liquid helium-cooled, black baffles to divide the spectrometer into three separate compartments. The system noise-equivalent flux density, when used on the 152 cm telescope from 8 to 13 microns with a resolving power of 50, is 4.4 x 10 to the minus 17th power W/sq cm micron square root of Hz. The main applications are for measuring continuum radiation levels and solid state emission and absorption features in regions of star and planet formation.

Witteborn, F. C.

Photometric imaging near infrared spectrometer

A description of the design and performance of an imaging spectrometer intended for operation in the seven to fourteen micrometer wavelength range is presented. It is based upon a sixteen by sixteen element Si:Bi hybrid array, a circular variable filter wheel, and a microcomputer data acquisition system. The spatial-spectral photometric performances have been evaluated in the laboratory as well as field tested at astronomical observatories. The performance characteristics of the system are presented as well as laboratory and astronomical images.

Goebel, J. H.

Absorption features in the 5-8 micron spectra of protostars

High signal-to-noise ratio spectra in the range of 5-8 microns of four sources embedded in molecular clouds are examined using low-temperature laboratory measurements of the 5-8-micron spectra of simple molecules and their mixtures. The absorption, apparent in all four sources, is characterized by highly distinct features ranging from two relatively narrow bands at 6.0 and 6.8 microns in W33A to a broad, shallow, and partially structured feature extending from 5.2 to 7.8 microns in Mon R2-IRS2, BN, and NGC2264. The first feature (W33A) is explained by the OH bending mode in H2O and the CH deformation modes in saturated hydrocarbons; while the second feature (Mon R2-IRS2-type) is explained by the presence of a mixture of saturated and unsaturated hydrocarbons possibly containing strongly electronegative groups.

Tielens, A. G. G. M.

8- to 13-micron spectrophotometry of Comet IRAS-Araki-Alcock

Spectrophotometry between 8.0 and 13.0 microns at 2 percent spectral resolution is presented for areas in and near the nuclear condensation of Comet IRAS-Araki-Alcock (1983d) on May 11 and 12, 1983. All the spectra can be fit very well by blackbody curves, and no 10-micron silicate emissions are seen. The temperature structure of the coma suggests the presence of small (radii less than 5 microns) dust particles within 150 km of the nucleus and larger ones further out. The change in the spatial distribution of the infrared flux between the two nights suggests that an outburst may have occurred sometime on May 11.

Feierberg, M. A.

A cryogenically cooled, multidetector spectrometer for infrared astronomy

A liquid helium-cooled, 24 detector grating spectrometer was developed and used for low resolution astronomical observations in the 5 to 14 micron spectral range. The instrument operated on the 91 cm Kuiper Airborne Observatory, the 3 m IRTF (Mauna Kea), the 3 m Shane telescope Observatory, the 3 m Shane telescope (Lick Observatory), and the 152 cm NASA and University of Arizona telescope. The detectors are discrete Si:Bi photoconductors with individual metal oxide semiconductor field effect transistor preamplifiers operating at 4 K. The system uses a liquid helium-cooled slit, order-sorter filter, collimator mirror, grating, and camera mirror arranged in a Czerny-Turner configuration with a cold stop added between the collimator mirror and the grating. The distances between components are chosen so that the collimator mirror images the secondary mirror of the telescope onto the cold stop, thus providing a very effective baffle. Scattered radiation is effectively reduced by using liquid helium-cooled, black baffles to divide the spectrometer into three separate compartments. The system noise-equivalent flux density, when used on the 152 cm telescope from 8 to 13 microns with a resolving power of 50, is 4.4 x 10 to the minus 17th power W/sq cm micron square root of Hz. The main applications are for measuring continuum radiation levels and solid state emission and absorption features in regions of star and planet formation.

Witteborn, F. C.

The unusual 8-13 micron spectrum of Markarian 231

An 8-13 micron spectrum was obtained of the Seyfert galaxy Markarian 231 with a spectral resolution of 0.22 micron per point. The spectrum is unlike any previously published spectrum at these wavelengths. The spectrum can be attributed to a combination of absorption and reemission by crystalline silicates which must have formed under conditions quite different from those in which silicates form in the Galaxy. Comparison of the data with previously published data indicates that the infrared emission is extended and not dominated by a bright central source.

Bregman, J. D.

Thermal contacts between metal and glass for use at cryogenic temperatures

Thermal contacts designed to cool a 50-cm diam fused-silica mirror to 5 K without serious distortion of the optical surfaces were tested. Rubber cement and copper-filled rubber cement were found to be well suited for maintaining thermal contact between the fused-silica and copper straps. A variety of other adhesives proved to be unreliable because they spalled the glass. The thermal resistances of the rubber cement and copper-filled rubber cement were determined. For the copper-filled rubber cement, the thermal resistances varied from 570 K/W at 60 K to 15,000 K/W at 10 K.

Obrien, K.

Detection of silicate emission features in the 8- to 13-micron spectra of main belt asteroids

A presentation is given of 8.0-13.0 micron spectra (Delta lambda/lambda = 0.02-0.03) for six main belt asteroids, which range from 58 to 220 km in diameter and sample the five principal taxonomic classes (C, S, M, R and E). Narrow, well-defined silicate emission features are present on two of the asteroids, the C-type 19 Fortuna and the M-type 21 Lutetia. No comparable emission features are observed on the S-types 11 Parthenope and 14 Irene, the R-type 349 Dembowska or the E-type 64 Angelina.

Feierberg, M. A.

Observations of NGC 7027 from 5.2 to 7.5 microns - The detection of Ni II and additional dust features

NGC 7027 was observed with a multichannel grating spectrometer from 5.2 to 7.5 microns at a spectral resolving power of 120-200. Two new dust emission features are resolved at 5.62 and 6.95 microns, and for the first time the Ni II fine-structure line at 6.64 microns is detected. It is shown that a single molecular dust constituent might account for six of the nine observed dust features between 2 and 14 microns. The strength of the Ni II line indicates either that Ni is not depleted in the neutral gas, or that the line is formed at high density.

Bregman, J. D.

Spectroscopic measurements of the 8- to 13-micrometer transmission of the upper atmosphere following the El Chichon eruptions

Infrared transmission spectra of the atmosphere above 11-km altitude were obtained at latitudes from 2 deg S to 50 deg N in December 1982. A circular variable-interference filter spectrometer mounted in a Convair 990 (the Galileo II) aircraft was used to obtain spectra of the sun through different air masses. Comparisons of spectra through different air masses provide atmospheric transmission measurements that show not only normal absorption features, such as those from CO2 and O3, but also additional absorption near 8.5 microns consistent with H2SO4 aerosols. The average fractional absorption from latitude 10 deg N to 41 deg N at 8.5 microns was 0.02/air mass, half of which was attributable to aerosols.

Witteborn, F. C.

The C2H, C2, and CN electronic absorption bands in the carbon star HD 19557

Infrared spectrophotometry of the R-type carbon star HD 19557 is presented. Two unusual spectroscopic features are seen: a 3.1 micron band is lacking and a 2.8 micron band is present. Identifications are proposed for three previously unreported stellar absorption bands with electronic sequences of C2, CN, and C2H. The latter is proposed to be responsible for the 2.8 micron feature. The atmospheric structure of the star is studied with synthetic spectra, and an effective temperature between 2600 K and 3000 K is suggested. No SiC emission is seen at 11.3 microns, indicating that grain formation is not a viable process around the star. The lack of dust in R stars may suggest a salient difference between R and N types.

Goebel, J. H.

SIRTF - The Shuttle Infrared Telescope Facility

The Shuttle Infrared Telescope (SIRTF) is a 1-m class cryogenically cooled telescope to be operated from the shuttle as a facility for infrared astronomy. By exploiting the very low infrared background of space, SIRTF will achieve 100 to 1000 times the sensitivity currently attainable at infrared wavelengths between 2 and 200 microns. The scientific requirements of SIRTF, the current design concept, and the scientific capabilities of the systems are reviewed. We also review recent experimental results showing that mirrors made of glassy materials may be suitable for use in large cryogenic telescopes such as SIRTF.

Werner, M. W.

A search for fragmentation debris near Ursa Major Stream stars

Accretion models of planet formation and the early cratering history of the solar system suggest that planet formation is accompanied by a cloud of debris resulting from accumulation and fragmentation. A rough estimate of the infrared luminosities of debris clouds is presented for comparison with measured 10-micron luminosities of young stars. New measurements of 13 F, G, and K main-sequence stars of the Ursa Major Stream, which is thought to be about 270-million years old, place constraints on the amount of debris which could be present near these stars.

Witteborn, F. C.

Cryogenic testing of mirrors for infrared space telescopes

The Shuttle IR Telescope Facility (SIRTF) test apparatus can test candidate mirror materials as large as 66 cm in diameter, at temperatures as low as about 10 K, and is accurate enough to detect optical figure changes as small as a fraction of a wavelength from the room temperature figure. The fused silica mirrors currently undergoing testing in the SIRTF are sunk into a liquid He reservoir with copper straps, whose individual strands are soldered to small silver spots diffused throughout the unfigured side of the mirror to accomplish fast conductive cooling. Optical access to the cold mirror is by means of a small glass port in the vacuum chamber. An interferometer is used to examine the mirror figure throughout the cool-down. Interferograms are photographed, fringe patterns are digitized, and mirror figure contour plots are calculated by means of a computer.

Miller, J. H.

SIRTF - The Shuttle Infrared Telescope Facility

The Shuttle Infrared Telescope (SIRTF) is a 1-m class cryogenically cooled telescope to be operated from the Shuttle as a facility for infrared astronomy. By exploiting the very low infrared background of space, SIRTF will achieve 100 to 1000 times the sensitivity currently attainable at infrared wavelengths between 2 and 200 microns. The scientific requirements of SIRTF, the current design concept, and the scientific capabilities of the systems are reviewed. Recent experimental results are also reviewed showing that mirrors made of glassy materials may be suitable for use in large cryogenic telescopes such as SIRTF. Previously announced in STAR as N82-32207

Werner, M. W.

The abundance of argon at the galactic center

Measurements of forbidden line Ar II 6.99 micron and Pf alpha 7.45 micron made from the Kuiper Airborne Observatory are presented for Sgr A, the H II region at the center of the Galaxy. These line strengths, when combined with ground-based measurements, suggest a factor of enhancement of two in the Ar/H ratio in the galactic center region relative to that in the sun and in the solar neighborhood. The accuracy of the determination is presently limited by the uncertainty in the collision strength for Ar(+).

Lester, D. F.

Identification of new infrared bands in a carbon-rich Mira variable

Complete 0.75-13 micron spectrometry of a carbon-rich, Mira-class variable star is presented for the first time. It is noted that although the near-infrared is dominated by photospheric absorption bands of the CN red system, the infrared becomes progressively dominated by the bands of the polyatomic molecules HCN and C2H2. Since the band at 3.1 microns is known to be due to HCN and C2H2, it is possible to associate bands at 1.04, 1.53, 1.85, 2.5, 2.7, 3.56, 3.85, 4.8, and 7.1 microns with HCN and C2H2. The spectrum suggests that radiative transfer in the carbon Mira class cannot be discussed quantitatively without the inclusion of HCN and C2H2 opacity. On the basis of the carbon star models of Querci and Querci (1974), it is deduced that the abundance ratio of HCN to C2H2 can be used to indicate whether 3-alpha-processed or CNO-processed material is in the outer atmosphere. An 11.3 micron SiC dust-emission feature is present, although it differs significantly from the 11.7 micron SiC feature in Y CVn. A featureless emission is present from 4 to 13 microns and can be ascribed to optically thin graphite grains having a temperature of 450 K.

Goebel, J. H.

Observations of Saturn in the 5- to 8-micron spectral region

A spectrum of Saturn obtained from the Kuiper Airborne Observatory exhibits an emission peak at 6.8 microns attributed to ethane, but is otherwise dominated by absorption from 5.3 to 7.2 microns. While the large absorption in this spectral region is consistent with the presence of ammonia gas or ammonia ice, or both, such an explanation is inconsistent with the lack of a major absorption near 3.0 microns.

Witteborn, F. C.