Advanced Optical Measurement Techniques

This research analyzes four areas: (1) Improved Techniques for Optical Measurement; (2) KC-135 Low Gravity Simulation Flight Preparation; (3) In-Line Holographic Microscopy; and (4) Holographic Optical Schlieren System (HOSS). The first task provides for laboratory breadboarding of advanced optical measurement techniques which appear promising for use in Material Processing System (MPS) flight experiments. A laboratory schlieren system has been constructed which simulates a similar optical system on the Fluids Experiment System (FES) which is to be flown on Spacelab 3. The second task allows improved optical systems and breadboards to be built for experiments and hardware tests on the KC-135 aircraft. A new, more stable Mach-Zehnder interferometer has been developed and components have been ordered. The third task is concerned with improvements on the optical system being used to study immiscible fluids. Experiments studying the dynamics of nucleation and the separation of immiscible fluids have been conducted. The four task involves building breadboard reconstruction systems for holograms taken in the HOSS. The HOSS is an early prototype of the Fluids Experiments System (FES) which is scheduled to fly on Spacelab 3.

Owen, R. B.

Optical studies of a binary miscibility gap system

Model transparent fluids are being studied to develop a better understanding of phase separation processes in binary miscibility-gap metal alloys. The model selected for the reported work is diethylene glycol-ethyl salicylate. This system is well characterized with respect to its phase diagram, density, surface and interfacial tensions, viscosity, and other pertinent physical properties. Minority phase growth, coalescence, and droplet motions are observed using holographic microscopy which is capable of recording particle densities up to 10 to the 7th particles/cu cm and is able to resolve particles as small as 2 to 3 microns in diameter throughout the entire volume of the test cell. Sequential holograms allow determination of droplet size distribution changes throughout the total volume with respect to time and temperature. This allows a direct method for testing various theories of droplet growth and ripening phenomena.

Witherow, W. K.

Imaging Fluid Flow

Electro-optical system allows simultaneous viewing of schlieren, shadowgraph and interferometric images of volume of fluid under test. In imaging system cube beam splitters replaced by plate-type beam splitters or pellicle beam splitters.

Witherow, W. K.

Separation processes during binary monotectic alloy production

Observation of microgravity solidification processes indicates that outside of sedimentation, at least two other important effects can separate the phases: critical-point wetting and spreading; and thermal migration of second-phase droplets due to interfacial tension gradients. It is difficult to study these surface tension effects while in a unit gravity field. In order to investigate the processes occurring over a temperature range, i.e., between a consolute point and the monotectic temperature, it is necessary to use a low-gravity environment. The MSFC drop tube (and tower), the ballistic trajectory KC-135 airplane, and the Space Shuttle are ideal facilities to aid formation and testing of hypotheses. Much of the early work in this area focuses on transparent materials so that process dynamics may be studied by optical techniques such as photography for viewing macro-processes; holography for studying diffusional growth; spinodal decomposition and coalescence; ellipsometry for surface wetting and spreading effects; and interferometry and spectroscopy for small-scale spatial resolution of concentration profiles.

Frazier, D. O.

Method of and apparatus for double-exposure holographic interferometry

Double-exposure holographic interferometry is carried out using first and second lasers responsive to respective applied firing signals for producing respective pulsed output beams. An optical system is provided oriented such that the output beams of the lasers produce coinciding scene and reference beams. An initiator circuit generates and applies a firing signal to the first laser; and a timer/firing device responsive to the generation of a firing signal by the initiator circuit, generates and applies a firing signal to the second laser a predetermined period of time later.

Witherow, W. K.

Dual laser optical system and method for studying fluid flow

A dual laser optical system and method is disclosed for visualization of phenomena in transport substances which induce refractive index gradients such as fluid flow and pressure and temperature gradients in fluids and gases. Two images representing mutually perpendicular components of refractive index gradients may be viewed simultaneously on screen. Two lasers having wave lengths in the visible range but separated by about 1000 angstroms are utilized to provide beams which are collimated into a beam containing components of the different wave lengths. The collimated beam is passed through a test volume of the transparent substance. The collimated beam is then separated into components of the different wave lengths and focused onto a pair of knife edges arranged mutually perpendicular to produce and project images onto the screen.

Owen, R. B.

Holographic Microscopy System

Holographic system originally developed for testing theories of two systems used for measurements of aerosols, particles in transparent medium or microscopic biological specimens. Holograms are recorded in 3 - to 5milli-second exposures on high-resolution holographic film. In-line holographic microscopy system includes construction or recording system and reconstruction or playback system.

Witherow, W. K.

Optical Studies of model binary miscibility gap system

In order to develop a better understanding of separation processes in binary miscibility gap metal alloys, model transparent fluid systems were studied. The system selected was diethylene glycol-ethyl salicylate which has convenient working temperatures (288 to 350 K), low toxicity, and is relatively easy to purify. The system is well characterized with respect to its phase diagram, density, surface and interfacial tensions, viscosity and other pertinent physical properties. Studies of migration of the dispersed phase in a thermal gradient were performed using conventional photomicroscopy. Velocities of the droplets of the dispersed phase were measured and compared to calculated rates which included both Stokes and thermal components. A holographic microscopy system was used to study growth, coalescence, and particle motions. Sequential holograms allowed determination of particle size distribution changes with respect to time and temperature. Holographic microscopy is capable of recording particle densities up to 10 to the 7th power particles/cu cm and is able to resolve particles of the order of 2 to 3 microns in diameter throughout the entire volume of the test cell. The reconstructed hologram produces a wavefront that is identical to the original wavefront as it existed when the hologram was made. The reconstructed wavefront is analyzed using a variety of conventional optical methods.

Lacy, L. L.

Holographic microscopy studies of emulsions

A holographic microscopy system that records and observes the dynamic properties of separation of dispersed immiscible fluids is described. The holographic construction system and reconstruction system that were used to obtain particle size and distribution information from the holograms are discussed. The holographic microscopy system is used to observed the phase separating processes in immiscible fluids that were isothermally cooled into the two phase region. Nucleation, growth rates, coalescence, and particle motion are successfully demonstrated with this system. Thus a holographic particle sizing system with a resolution of 2 micrometers and a field of view of 100 cu cm was developed that provides the capability of testing the theories of separating immiscible fluids for particle number densities in the range of 10 to 10 to the 7th power particles.

Witherow, W. K.

A high resolution holographic particle sizing system

This paper will review briefly the requirements of holography with respect to particle sizing techniques. A holographic construction system and the appropriate reconstruction system will be discussed regarding their characteristics and performance (i.e. system resolution, magnification, system aberration and correction of aberrations, and maximum total test volume). The capabilities of a commercial particle sizing system used to obtain particle sizes and distribution information from reconstructed holograms will be described and characterized. It will be shown that by using the methods described, high resolution throughout large test volumes can be achieved.

Witherow, W. K.

Some limitations on processing materials in acoustic levitation devices

The spot heating of samples, suspended in an acoustic field, was investigated to determine if the technique could be used to process materials. A single axis resonance device operating in air at 25 C with an rms pressure maximum of 160 to 170 db was used in the experiments. The heat flow from a hot object suspended in a levitation node is dominated by the effects of the field, with the heat loss approximately 20 times larger than that due to natural convection. The acoustic forces which suspend the body at a node also serve to eject the heated air. The coupling between the locally heated region around the body and the acoustic field results in instabilities in both the pressure wave and force field. The investigations indicated the extreme difficulties in developing a materials processing device based on acoustic/spot heating for use in a terrestrial environment.

Oran, W. A.