Engineering Papers⌕ Search

Engineering topics

Wiseman, C.

Publications and source records attributed to Wiseman, C..

At least 37 records · Page 2

Results of the MAJORANA DEMONSTRATOR’s Search for Double-Beta Decay of 76 Ge to Excited States of 76 Se

The MAJORANA DEMONSTRATOR is searching for double-beta decay of 76 Ge to excited states (E.S.) in 76Se using a modular array of high purity Germanium detectors. 76 Ge can decay into three E.S.s of 76 Se. The E.S. decays have a clear event signature consisting of a ββ-decay with the prompt emission of one or two γ-rays, resulting in with high probability in a multi-site event. The granularity of the DEMONSTRATOR detector array enables powerful discrimination of this event signature from backgrounds. Using 21.3 kg-y of isotopic exposure, the DEMONSTRATOR has set world leading limits for each E.S. decay, with 90% CL lower half-life limits in the range of (0.56 – 2.1) • 10 24 y. In particular, for the 2v transition to the first 0 + E.S. of 76 Se, a lower half-life limit of 0.68 • 10 24 at 90% CL was achieved.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design improvements to cables and connectors in the Majorana Demonstrator

The Majorana Demonstrator is an experiment constructed to search for neutrinoless double-beta decays in germanium-76 and to demonstrate the feasibility to deploy a ton-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and 76 Ge-enriched germanium p-type point contact detectors totaling 44.1 kg, located at the 4850 level of the Sanford Underground Research Facility in Lead, South Dakota, USA. The Demonstrator uses custom high voltage cables to bias the detectors, as well as custom signal cables and connectors to read out the charge deposited at the point contact of each detector. These low-mass cables and connectors must meet stringent radio purity requirements while being subjected to thermal and mechanical stress. A number of issues have been identified with the currently installed cables and connectors. An improved set of cables and connectors for the Majorana Demonstrator are being developed with the aim of increasing their overall reliability and connectivity. In conclusion, we will discuss some of the issues encountered with the current cables and connectors as well as our improved designs and their initial performance.

42 ENGINEERING↗

Search for neutrinoless double- β decay in Ge 76 with 26 kg yr of exposure from the Majorana Demonstrator

The MAJORANA Collaboration is operating an array of high purity Ge detectors to search for the neutrinoless double-beta decay of $^{76}$Ge. The MAJORANA DEMONSTRATOR consists of 44.1 kg of Ge detectors (29.7 kg enriched to 88% in $^{76}$Ge) split between two modules constructed from ultra-clean materials. Both modules are contained in a low-background shield at the Sanford Underground Research Facility in Lead, South Dakota. We present updated results on the search for neutrinoless double-beta decay in $^{76}$Ge with $26.0\pm0.5$ kg-yr of enriched exposure. With the DEMONSTRATOR's unprecedented energy resolution of 2.53 keV FWHM at $Q_{\beta\beta}$, we observe one event in the region of interest with 0.65 events expected from the estimated background, resulting in a lower limit on the $^{76}$Ge neutrinoless double-beta decay half-life of $2.7\times10^{25}$ yr (90% CL) with a median sensitivity of $4.8\times10^{25}$ yr (90% CL). Depending on the matrix elements used, a 90% CL upper limit on the effective Majorana neutrino mass in the range of 200-433 meV is obtained. The measured background in the low-background configurations is $11.9\pm2.0$ counts/(FWHM t yr).

59 ≤ A ≤ 89↗

Recent results from the Majorana Demonstrator

The MAJORANA DEMONSTRATOR is an experiment constructed to search for Neutrinoless double-beta decay in 76Ge and to demonstrate the feasibility to deploy a large-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and 76Ge-enriched germanium detectors totalling 44.1 kg, operating on the 4850’ level of the Sanford Underground Research Facility in Lead, South Dakota, USA. Data acquisition in the commissioning phase began in June 2015, followed by data acquisition with the full detector array in August 2016. The ultralow background and record energy resolution achieved by the MAJORANA DEMONSTRATOR enable a sensitive neutrinoless double-beta decay search, as well as additional searches for physics beyond the Standard Model. I will discuss the design elements that enable these searches, along with our latest results, focusing on the neutrinoless double-beta decay search. I will also discuss the current status and the future plans of the MAJORANA DEMONSTRATOR, as well as the plans for a future tonne-scale 76Ge experiment.

Myslik, Jordan W.↗

Multisite event discrimination for the majorana demonstrator

The MAJORANA DEMONSTRATOR is searching for neutrinoless double-beta decay($0\nu\beta\beta$) in 76 Ge using arrays of point-contact germanium detectors operating at the Sanford Underground Research Facility. Background results in the $0\nu\beta\beta$ region of interest from data taken during construction, commissioning, and the start of full operations have been recently published. A pulse shape analysis cut applied to achieve this result, named AvsE , is described in this paper. This cut is developed to remove events whose waveforms are typical of multi-site energy deposits while retaining (90 ± 3.5)% of single-site events. This pulse shape discrimination is based on the relationship between the maximum current and energy, and tuned using 228 Th calibration source data. In conclusion, the efficiency uncertainty accounts for variation across detectors, energy, and time, as well as for the position distribution difference between calibration and $0\nu\beta\beta$ events, established using simulations.

59 ≤ A ≤ 89↗

The Majorana Demonstrator Status and Preliminary Results

The MAJORANA Collaboration is using an array of high-purity Ge detectors to search for neutrinoless double-beta decay in 76 Ge. Searches for neutrinoless double-beta decay are understood to be the only viable experimental method for testing the Majorana nature of the neutrino. Observation of this decay would imply violation of lepton number, that neutrinos are Majorana in nature, and provide information on the neutrino mass. The MAJORANA DEMONSTRATOR comprises 44.1 kg of p-type point-contact Ge detectors (29.7 kg enriched in 76 Ge) surrounded by a low-background shield system. The experiment achieved a high efficiency of converting raw Ge material to detectors and an unprecedented detector energy resolution of 2.5 keV FWHM at Q ββ . The MAJORANA collaboration began taking physics data in 2016. Here, this paper summarizes key construction aspects of the Demonstrator and shows preliminary results from initial data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Recent Results from the Majorana Demonstrator

The MAJORANA Collaboration has completed construction and is now operating an array of high purity Ge detectors searching for neutrinoless double-beta decay ($0\nu\beta\beta$) in $^{76}$Ge. The array, known as the MAJORANA DEMONSTRATOR, is comprised of 44 kg of Ge detectors (30 kg enriched to 88% in $^{76}$Ge) installed in an ultra-low background compact shield at the Sanford Underground Research Facility in Lead, South Dakota. The primary goal of the DEMONSTRATOR is to establish a low-background design that can be scaled to a next-generation tonne-scale experiment. This work reports initial background levels in the $0\nu\beta\beta$ region of interest. Also presented are recent physics results leveraging P-type point-contact detectors with sub-keV energy thresholds to search for physics beyond the Standard Model; first results from searches for bosonic dark matter, solar axions, Pauli exclusion principle violation, and electron decay have been published. Finally, this work discusses the proposed tonne-scale $^{76}$Ge $0\nu\beta\beta$ LEGEND experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Contamination control and assay results for the Majorana Demonstrator ultra clean components

The Majorana Demonstrator is a neutrinoless double beta decay experiment utilizing enriched Ge-76 detectors in 2 separate modules inside of a common solid shield at the Sanford Underground Research Facility. The Demonstrator has utilized world leading assay sensitivities to develop clean materials and processes for producing ultra-pure copper and plastic components. This experiment is now operating, and initial data provide new insights into the success of cleaning and processing. Post production copper assays after the completion of Module 1 showed an increase in U and Th contamination in finished parts compared to starting bulk material. A revised cleaning method and additional round of surface contamination studies prior to Module 2 construction have provided evidence that more rigorous process control can reduce surface contamination. In conclusion, this article describes the assay results and discuss further studies to take advantage of assay capabilities for the purpose of maintaining ultra clean fabrication and process design.

36 MATERIALS SCIENCE↗

Low background materials and fabrication techniques for cables and connectors in the Majorana Demonstrator

Here, the Majorana Collaboration is searching for the neutrinoless double-beta decay of the nucleus 76 Ge. The Majorana Demonstrator is an array of germanium detectors deployed with the aim of implementing background reduction techniques suitable for a tonne scale 76 Ge-based search (the LEGEND collaboration). In the Demonstrator, germanium detectors operate in an ultra-pure vacuum cryostat at 80 K. One special challenge of an ultra-pure environment is to develop reliable cables, connectors, and electronics that do not significantly contribute to the radioactive background of the experiment. This paper highlights the experimental requirements and how these requirements were met for the Majorana Demonstrator, including plans to upgrade the wiring for higher reliability in the summer of 2018. Also described are requirements for LEGEND R&D efforts underway to meet these additional requirements

74 ATOMIC AND MOLECULAR PHYSICS↗

The status and initial results of the Majorana demonstrator experiment

Neutrinoless double-beta decay searches play a major role in determining the nature of neutrinos, the existence of a lepton violating process, and the effective Majorana neutrino mass. The Majorana Collaboration assembled an array of high purity Ge detectors to search for neutrinoless double-beta decay in 76 Ge. The Majorana Demonstrator is comprised of 44.1 kg (29.7 kg enriched in 76 Ge) of Ge detectors divided between two modules contained in a low-background shield at the Sanford Underground Research Facility in Lead, South Dakota, USA. The initial goals of the Demonstrator are to establish the required background and scalability of a Ge-based next-generation ton-scale experiment. Following a commissioning run that started in 2015, the first detector module started low-background data production in early 2016. The second detector module was added in August 2016 to begin operation of the entire array. Lastly, we discuss results of the initial physics runs, as well as the status and physics reach of the full Majorana Demonstrator experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Initial Results from the Majorana Demonstrator

Neutrinoless double-beta decay searches seek to determine the nature of neutrinos, the existence of a lepton violating process, and the eective Majorana neutrino mass. The Majorana Collaboration is assembling an array of high purity Ge detectors to search for neutrinoless double-beta decay in 76Ge. The Majorana Demonstrator is composed of 44.8 kg (29.7 kg enriched in 76Ge) of Ge detectors in total, split between two modules contained in a low background shield at the Sanford Underground Research Facility in Lead, South Dakota. The initial goals of the Demonstrator are to establish the required background and scalability of a Ge-based, next-generation, tonne-scale experiment. Following a commissioning run that began in 2015, the rst detector module started physics data production in early 2016. We will discuss initial results of the Module 1 commissioning and rst physics run, as well as the status and potential physics reach of the full Majorana Demonstrator experiment. The collaboration plans to complete the assembly of the second detector module by mid-2016 to begin full data production with the entire array.

Majorana Demonstrator↗

The Majorana Demonstrator calibration system

The Majorana Collaboration is searching for the neutrinoless double-beta decay of the nucleus 76 Ge. The Majorana Demonstrator is an array of germanium detectors deployed with the aim of implementing background reduction techniques suitable for a 1-ton 76 Ge-based search. The ultra low-background conditions require regular calibrations to verify proper function of the detectors. Radioactive line sources can be deployed around the cryostats containing the detectors for regular energy calibrations. When measuring in low-background mode, these line sources have to be stored outside the shielding so they do not contribute to the background. The deployment and the retraction of the source are designed to be controlled by the data acquisition system and do not require any direct human interaction. In this study, we detail the design requirements and implementation of the calibration apparatus, which provides the event rates needed to define the pulse-shape cuts and energy calibration used in the final analysis as well as data that can be compared to simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Muon flux measurements at the davis campus of the sanford underground research facility with the majorana demonstrator veto system

We report the first measurement of the muon flux underground at the Davis Campus of the Sanford Underground Research Facility at the 4850 foot level. Measurements were done with the Majorana Demonstrator veto system arranged in two different configurations. Both results are in agreement within statistical accuracy. The measured flux is (4.08+-0.19) x 10 -9 muons/cm/2. We compare our results with previous calculations.

Abgrall, N.↗

New Limits on Bosonic Dark Matter, Solar Axions, Pauli Exclusion Principle Violation, and Electron Decay from the Majorana Demonstrator

Here, we present new limits on exotic keV-scale physics based on 478 kg d of Majorana Demonstrator commissioning data. Constraints at the 90% confidence level are derived on bosonic dark matter (DM) and solar axion couplings, Pauli exclusion principle violating (PEPV) decay, and electron decay using monoenergetic peak signal limits above our background. We set our most stringent DM constraints for 11.8 keV mass particles, limiting g A e < 4.5 × 10 -13 for pseudoscalars and ( α ' / α ) < 9.7 × 10 -28 for vectors. We also report a 14.4 keV solar axion coupling limit of g$eff\atop{AN}$ × g A e < 3.8 × 10 -17 , a 1/2 β 2 < 8.5 × 10 - 48 limit on the strength of PEPV electron transitions, and a lower limit on the electron lifetime of τ e > 1.2 × 1 0 24 yr for e - → invisible.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗