Engineering PapersSearch

Engineering topics

Winkler, H. E.

Publications and source records attributed to Winkler, H. E..

Shuttle Orbiter Environmental Control and Life Support System - Flight experience

This paper describes the overall design of the Shuttle Orbiter Environmental Control and Life Support System (ECLSS). The Orbiter ECLSS consists of six major subsystems which accomplish the functions of providing a habitable pressurized cabin atmosphere and removing gaseous contaminants, controlling the temperature of the cabin and vehicle components within acceptable ranges, providing fire detection and suppression capability, maintaining a supply of potable water, collecting and removing metabolic waste materials, and providing utilities and access for extravehicular activity. The operational experience is summarized for the 45 space flights accomplished to date during which the Orbiter ECLSS has been demonstrated to perform reliably, and has proved to have the flexibility to meet a variety of mission needs. Significant flight problems are described, along with the design or procedure changes which were implemented to resolve the problems.

Winkler, H. E.

The extended duration orbiter waste collection system

A new waste collection system (WCS) is undergoing development for use in the extended duration orbiter (EDO). Requirements for missions up to 18 days and the capability for missions up to 30 days necessitate the development of a new WCS that will have the appropriate capacity. The new system incorporates design features from both Skylab and Space Shuttle Orbiter WCSs. The system for EDO utilizes redundant fans and urine separators. Plans call for the new WCS to be implemented for OV-105 (Endeavor) as well as for EDO. This paper describes the design and development status of the new WCS.

Brasseaux, Hubert J., Jr.

The Extended Duration Orbiter Regenerable CO2 Removal System

A new carbon dioxide scrubber system is undergoing development for extended duration orbiter (EDO) missions. The EDO requirements of missions up to 18 days and the capability for future missions up to 30 days necessitated the development and implementation of a regenerative CO2 removal process. This new system will reduce the launch weight and stowage volume as compared to the present method of CO2 removal, lithium hydroxide, which is stowed in canisters. The selected design, called the Regenerable CO2 Removal System (RCRS), uses a solid amine material to adsorb carbon dioxide and water vapor and periodically desorb these to space vacuum. The RCRS, which is located below the middeck floor, interfaces with the orbiter's cabin Atmospheric Revitalization System and is adjustable from four to seven crewmembers. The RCRS is designed to automatically cycle the beds from absorb to vacuum-desorb every 30 minutes. Also incorporated into the design are features such consumable recovery, external leak protection, trace contaminant control and automatic control logic operation.

Ouellette, Fred A.

Thermoelectric Integrated Membrane Evaporation Subsystem operational improvements

A three-man preprototype Thermoelectric Integrated Membrane Evaporation Subsystem (TIMES) has been developed to provide high quality water recovery from waste fluids on extended duration space flights. In the most recent effort, a number of improvements have been made to simplify subsystem operation and increase performance. These modifications include changes to the hollow fiber membrane evaporator, the condensing section of the thermoelectric heat pump, and the electronic controller logic and display. This paper describes the results of the test program that was conducted to evaluate the implemented improvements. In addition, an advanced design concept is discussed that will provide lower electrical power consumption, greater water production capacity, lower weight, and a smaller package than the present subsystem configuration.

Dehner, G. F.

Integrated water management system - Description and test results

Water recovery subsystems are being tested at the NASA Lyndon B. Johnson Space Center for Space Station use to process waste water generated from urine and wash water collection facilities. These subsystems are being integrated into a water management system that will incorporate wash water and urine processing through the use of hyperfiltration and vapor compression distillation subsystems. Other hardware in the water management system includes a whole body shower, a clothes washing facility, a urine collection and pretreatment unit, a recovered water post-treatment system, and a water quality monitor. This paper describes the integrated test configuration, pertinent performance data, and feasibility and design compatibility conclusions of the integrated water management system.

Elden, N. C.

Urine pretreatment for waste water processing systems

Recovery of high quality water from urine is an essential part of life support on a Space Station to avoid costly launch and resupply penalties. Water can be effectively recovered from urine by distillation following pretreatment by a chemical agent to inhibit microorganism contamination and fix volatile ammonia constituents. This paper presents the results of laboratory investigations of several pretreatment chemicals which were tested at several concentration levels in combination with sulfuric acid in urine. The optimum pretreatment formulation was then evaluated with urine in the Hamilton Standard Thermoelectric Integrated Membrane Evaporation Subsystem (TIMES). Over 2600 hours of test time was accumulated. Results of these laboratory and system tests are presented in this paper.

Winkler, H. E.

Thermoelectric integrated membrane evaporation water recovery technology

The recently developed Thermoelectric Integrated Membrane Evaporation Subsystem (TIMES) offers a highly competitive approach to water recovery from waste fluids for future on-orbit stations such as the Space Operations Center. Low power, compactness and gravity insensitive operation are featured in this vacuum distillation subsystem that combines a hollow fiber membrane evaporator with a thermoelectric heat pump. The hollow fiber elements provide positive liquid/gas phase control with no moving parts other than pumps and an accumulator, thus solving problems inherent in other reclamation subsystem designs. In an extensive test program, over 850 hours of operation were accumulated during which time high quality product water was recovered from both urine and wash water at an average steady state production rate of 2.2 pounds per hour.

Roebelen, G. J., Jr.

Electrophotolysis oxidation system for measurement of organic concentration in water

Methods and apparatus for determining organic carbon in aqueous solution are described. The method comprises subjecting the aqueous solution to electrolysis, for generating oxygen from water, and simultaneously to ultraviolet radiation, for oxidation of substantially all organic carbon to carbon dioxide. The carbon dioxide is measured and the value is related to the concentration of organic carbon in the aqueous solution.

Winkler, H. E.

Bio-medical flow sensor

A bio-medical flow sensor including a packageable unit of a bottle, tubing and hypodermic needle which can be pre-sterilized and is disposable. The tubing has spaced apart tubular metal segments. The temperature of the metal segments and fluid flow therein is sensed by thermistors and at a downstream location heat is input by a resistor to the metal segment by a control electronics. The fluids flow and the electrical power required for the resisto to maintain a constant temperature differential between the tubular metal segments is a measurable function of fluid flow through the tubing. The differential temperature measurement is made in a control electronics and also can be used to control a flow control valve or pump on the tubing to maintain a constant flow in the tubing and to shut off the tubing when air is present in the tubing.

Winkler, H. E.

Flow sensor for biomedical fluids

Electronic sensor accurately measures and controls flow of plasma, whole blood, or drugs in solution. Since sensor does not directly contact fluid, it does not have to be sterilized. It is compatible with disposable bottles, tubes, and hypodermic needles widely used in hospitals. Only modification necessary is in tube, which must contain two small metal inserts, spaced to fit in curved thermistor plates.

Winkler, H. E.

Development of a preprototype thermoelectric integrated membrane evaporation subsystem for water recovery

A three-man urine water recovery preprototype subsystem using a new concept to provide efficient potable water recovery from waste fluids on extended duration space flights has been designed, fabricated, and tested. Low power, compactness, and gravity insensitive operation are featured in this vacuum distillation subsystem that combines a hollow fiber polysulfone membrane evaporator with a thermoelectric heat pump. Application and integration of these key elements have solved problems inherent in previous reclamation subsystem designs. The hollow fiber elements provide positive liquid/gas phase control with no moving parts other than a waste liquid recirculation pump and a product water withdrawal pump. Tubular membranes provide structural integrity, improving on previous flat sheet membrane designs. A thermoelectric heat pump provides latent energy recovery.

Winkler, H. E.

Development of an advanced combined iodine dispenser/detector

Injection of iodine into water is widely used to control microbial growth. An entirely automated device for I2 injection has been developed for spacecraft application. Transfer of I2 into the water from a concentrated form is controlled electrochemically via feedback from an integrated photometric I2 level detector. All components are contained within a package weighing only 1.23 kg (2.7 lb) dry, which occupies only 1213 cu cm (74 cu in) of space, and which has the capacity to iodinate 10,900 kg (24,000 lb) of water of 5 ppm. These features exceed design specifications. The device performed satisfactorily during extended testing at variable water flow rates and temperatures. Designed to meet specifications of the Shuttle Orbiter, the device will find application in the regenerative water systems of advanced spacecraft.

Lantz, J. B.