Engineering PapersSearch

Engineering topics

Wilson, M. W.

Publications and source records attributed to Wilson, M. W..

A wire/extensometer method for measuring small displacements

A method has been developed for making precise point-to-point displacement measurements on critical structures under structural, thermal, or gravity loading. The technique consists of attaching the gauge to the structure at one point, and connecting it to a second point on the structure by a thin (0.25 mm) tungsten wire. The wire provides a dual function: in addition to physically connecting the gauge to a remote point, it provides a calibrating function. Tests have demonstrated that measurements can be made within a micron over a length of a meter or two, even in the presence of severe thermal shock, such as exposure to a sun gun or to a refrigerant spray.

Wilson, M. W.

International comparison of radiometers - Techniques and results.

Description of an international comparison of radiometers made on May 10 through 14, 1971, with 24 instruments, each one representing the calibration standard of a different country or a major laboratory. All were pyranometers, viewing the sun and sky, thus bypassing the conventional method of transferring the standard from Angstrom pyrheliometers. This is the first time that pyranometers from all around the globe have been brought together in order to verify the scale on which to report solar radiation data. A highly accurate data collection system measured simultaneously the output of each instrument and that of a reference standard at 20-sec intervals. Over 300,000 radiometric signals were recorded under varying atmospheric conditions, as well as data on turbidity, temperature, and other relevant parameters. Computer programs were developed for overnight analysis of the data and distribution to participants on the following day. Among major findings are that instruments of different types and independent calibration such as those of Eppley, U. S. A., World Radiation Center, Switzerland, and Melbourne, Australia, show better agreement than anticipated, that certain national standards have to be revised by as much as 16% and that the cosine factor is highly dependent on the type of instrument.

Thekaekara, M. P.

Gimbaled-mirror scanning system capable of spiral pattern

Gimbaled-mirror infrared radiation scanner, with a lightweight torque motor direct coupled to each axis, is capable of scanning in a highly efficient spiral pattern. The scanner is lightweight and can be remotely positioned in previously inaccessible areas because the radiometer head and the gimbaled-mirror scanner can be separated.

Haertsch, O. C.