Engineering PapersSearch

Engineering topics

Willocks, Jonathan [Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)] (ORCID:0000000223122436)

Publications and source records attributed to Willocks, Jonathan [Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)] (ORCID:0000000223122436).

High-gradient magnetic filtration of UO 2 colloids from aqueous suspensions

Environmental samples often contain innocuous components that make trace actinide analysis difficult and expensive. Therefore, it is expedient to separate these materials from actinide particles. One characteristic of many actinides is that they are paramagnetic. High-gradient magnetic filtration (HGMF) is a non-destructive technique that selectively captures magnetic constituents from a matrix containing non-magnetic species. Here, in this work, a novel HGMF device made of a permanent magnet array was used to effectively separate UO 2 particles from undesirable soil species. Up to 88% of the UO 2 particles present in suspensions were effectively captured by HGMF, resulting in their enrichment and a substantial reduction in the concentrations of other constituents.

Actinide separations

DeSelenator: A Se-Removal Process for Environmental Decontamination of Wastewaters from Coal-Burning Power Plants

Selenium may become a toxic contaminant of freshwater systems when released into the environment through industrial wastewaters from mining, coal-burning power plants, or oil refining. Efficient and cost-effective Se-removal technologies are therefore necessary to reduce Se concentrations in these wastewaters to below the regulatory discharge limits. In this study, we have demonstrated an effective process that removes Se, mostly as selenate anions, from wastewaters generated by coal-burning power plants. This process, dubbed DeSelenator, leverages the high concentration of sulfate relative to selenate in the wastewater and the propensity of these oxyanions to cocrystallize with benzene-bis-iminoguanidinium (BBIG) cations into extremely insoluble salts (on par with BaSO 4 ). The SO 4 2− /SeO 4 2− cocrystallization with BBIG removes over 90% of S and Se from the wastewater. Following removal of the precipitate by filtration, the filtrate is passed over an anion-exchange resin that further reduces selenium concentration to 5 ppb, the EPA’s regulatory limit for freshwater systems. Finally, the effluent is passed over an activated carbon column, which removes 99.8% of the residual BBIG ligand remaining after crystallization, allowing for the safe discharge of the treated water into the environment. The Se-removal process was first optimized in the lab at the bench scale and then tested in the field at the Tennessee Valley Authority’s Bull Run coal-burning power plant. A technoeconomic assessment found the cost of water treatment with DeSelenator is on par with that of the active biological method, which is currently considered a state-of-the-art Se-removal technology.

anions

Influence of extreme temperature conditions on CO 2 direct air capture using amino-acid solutions

Geological features play a pivotal role in determining the feasibility of deploying CO₂ direct air capture (DAC) technologies, primarily because they influence the availability of cost-effective energy sources, such as natural gas and geothermal energy, and also due to the potential for CO₂ sequestration. Many regions face challenges due to variable weather conditions including seasonal temperature fluctuations, high or low humidity, and sub-ambient temperatures. These extremes can reduce DAC performance or even lead to catastrophic events. Aqueous solvents considered for DAC systems are particularly vulnerable to seasonal variations in colder climates, where the solvent may underperform or freeze. It is therefore essential to investigate the CO₂ capture efficiency of aqueous solvents across a broad range of environmental temperatures, spanning sub-zero to hot conditions (>30 °C). In this study, DAC operation is examined using a high-flux solvent–air crossflow contactor under two major weather scenarios: (i) cold conditions below 0 °C and (ii) hot conditions above 30 °C. A parametric study is conducted to investigate the contactor performance regarding CO₂ removal efficiency, uptake capacity, and reaction kinetics versus temperature when the air velocity through the contactor exceeds 1 m/s. The efficacy of the contactor is systematically investigated using various anti-freeze amino-acid solvent formulations. A mass-transfer mechanistic model is developed to assess the process performance over a wide temperature range and propose scalable design guidelines. Machine learning is also employed to identify key parameters affecting the CO₂ capture efficiency. It is shown that air velocity and temperature are the primary factors influencing CO₂ uptake. Based on performance data obtained under subfreezing temperatures, a technoeconomic analysis is conducted to evaluate the feasibility of using aqueous solvents in seasonal cold regions. In conclusion, the findings of this study provide valuable insights into siting considerations for deploying solvent-based DAC, thereby contributing to the advancement of sustainable carbon removal solutions.

Air–liquid contactor

Selective capture and recovery of uranium oxide colloids from aqueous soil suspensions using high gradient magnetic filtration

High Gradient Magnetic Filtration (HGMF) is a promising method for the selective capture and recovery of uranium oxide from surface soils. To date, however, magnetic filtration of uranium oxide has only been demonstrated at a proof-of-principle scale using relatively small filters (<5 cm 3 ) at low flowrates (<60 mL/min). Here, to explore the efficacy of magnetic filtration of uranium oxide at a larger scale, a newly designed HGMF apparatus that is more than an order of magnitude larger than our earlier filters (106 cm 3 ) was designed, fabricated, and tested at relatively high flowrates. Filtration experiments were performed using aqueous uranium oxide particle suspensions with Arizona Road Dust (ARD) as a soil simulant. At a flowrate of 125 mL/min, the apparatus’ uranium capture rate was exceptionally high (96 %), but selectivity was poor due to the high rate of capture for diamagnetic soil constituents (e.g., 77 % for silicon). All particles were captured at a lower rate when the flowrate was increased to 250 mL/min, but uranium selectivity was significantly increased due to the more substantial reduction in diamagnetic particle capture (i.e., capture rate of 77 % and 15 % for uranium and silicon, respectively). When backwashing the apparatus at the same flowrates used during filtration experiments, the rate of uranium recovery tended to be fairly low. Nevertheless, higher flowrates (1 L/min) and sonication were both shown to be highly effective methods of increasing uranium recovery. Magnetic field simulations were also performed to investigate potential optimizations to the design of the apparatus. These simulations showed that the intensity of the applied magnetic field could be increased by increasing the thickness of the steel magnetic housing. Additionally, stochastic trajectory simulations were performed to investigate the potential mechanisms of particle capture.

HGMF