Engineering PapersSearch

Engineering topics

Williams, J. T.

Publications and source records attributed to Williams, J. T..

Coplanar waveguide feed for microstrip patch antennas

A coplanar waveguide (CPW) loop is shown to be an effective low VSWR feed for microstrip antennas. The low VSWR transition between the CPW and the antenna is obtained without the use of a matching circuit, and it is relatively insensitive to the position of the antenna and the feed.

Smith, R. L.

The prototype MOSAIC detector

The prototype of the MOSAIC (Mosaicked Optical Self-scanned Array Imaging Camera) system, a photon-counting detector designed for use in the far ultraviolet, is described. MOSAIC has a two-dimensional format of 2400 x 2400 pixels, and is easily expandable. Readout is accomplished electronically via charge-coupled devices, making possible remote observations. Preliminary results of computer simulations of the system are presented.

Weistrop, D.

MOSAIC

The Mosaicked Optical Self-scanned Array Imaging Camera (MOSAIC), is a 50 sq cm active area detector system encompassing 5.76 million picture elements. This camera is being developed for use in astronomical instrumentation requiring the use of large area imaging detectors with high resolution photon counting capability in the space ultraviolet. This paper gives a descriptive outline of the MOSAIC camera system including: the 100 mm diameter microchannel plate intensifier, the 3 x 3 array of 800 x 800 pixel charge coupled devices, the signal processing and buffer storage subsystem, the electronic support and control subsystem, and the data processing subsystem. Performance characteristics of the camera and its subsystems are presented, based on system analysis.

Williams, J. T.

Options for a new Arizona observatory - Configurations, costs and site

The process of creating a major observatory, with emphasis on the configurations, costs, and site involved, is examined. The premise that cost optimization starts with a modestly priced building block, such as a 7.5-m telescope, is considered. The telescope unit and the configurations in which it is used, ranging from a single telescope or a set of separate telescopes, to an MMT in which the light of all of the telescopes can be phased when desired, are described. It is shown that options exist for using elements in a nonredundant linear array or Michelson interferometer. A means of estimating costs of different facilities, all on the same basis, is provided. The importance of placing the observatory on a site, such as Mt. Graham in Arizona, which maximizes the output per unit cost of the facility is discussed.

Woolf, N. J.

Flux of optical meteors down to M sub pg = +12

Observations of the flux of optical meteors down to photographic magnitudes of +12 are reported. The meteors were detected by photometry using a 10-m optical reflector from December 12-15, 1974, during the Geminid shower. A total of 2222 light pulses is identified as coming from meteors within the 1 deg field of view of the detector, most of which correspond to sporadic meteors traversing the detector beam at various angles and velocities and do not differ with the date, indicating that the Geminid contribution at faint luminosities is small compared to the sporadic contribution. A rate of 1.1 to 3.3 x 10 to the -12th meteors/sq cm per sec is obtained together with a power law meteor spectrum which is used to derive a relationship between cumulative meteor flux and magnitude which is linear for magnitudes from -2.4 through +12. Expressions for the cumulative flux upon the earth's atmosphere and at a test surface at 1 AU far from the earth as a function of magnitude are also obtained along with an estimate of the cumulative number density of particles.

Cook, A. F.

Test results on intensified charge coupled devices

CCD imaging arrays were evaluated for a photon counting astronomical sensor. Results show noise corresponding to less than 100 rms electrons and gains of approximately 1000 at 10kV accelerating voltage (greater than 5000 at 25kV). Measured charge transfer efficiencies are in excess of 0.9999, signal saturation levels are as high as 990000 electrons per pixel and peak quantum efficiencies are greater than 75%. Successful proximity focussed intensified charge coupled devices (ICCD) have been fabricated, although problems still exist with contamination and possible structural failures in the CCD's during tube manufacture.

Williams, J. T.

The intensified charge coupled device as a photon counting imager

Actual and projected performance of an intensified charge coupled device (ICCD) to be used as a photon counting imager will be presented. Effects of tube processing on such important CCD parameters as charge transfer efficiency and dark current are discussed.

Williams, J. T.

Optical studies of meteors at Mount Hopkins Observatory

The 10-m optical reflector and an array of phototubes are used to extend the optical measurements beyond the present limit achieved by the Vidicon system. The first detection of optical meteors with M sub v = + 12 is reported. It is hoped that this system can be used to determine intermediate points in the meteor frequency mass curve for sporadic meteors and to study in detail the faint components of meteor showers. Preliminary observations made on three nights in September 1974 are presented.

Weekes, T. C.

Performance characteristics of proximity focused ultraviolet image converters

Performance characteristics of Bendix type BX 8025-4522 proximity focused image tubes for UV to visible light conversion are presented. Quantum efficiency, resolution, background, geometric distortion, and environmental test results are discussed. The converters use magnesium fluoride input windows with Cs-Te photocathodes and P-11 phosphors on fiber optic output windows.

Williams, J. T.

Performance characteristics of proximity focused ultraviolet image converters

Performance characteristics of Bendix type BX 8025-4522 proximity focused image tubes for ultraviolet to visible light conversion are presented. Quantum efficiency, resolution, background, geometric distortion, and environmental test results are discussed. The converters use magnesium fluoride input windows with Cs - Te photocathodes, and P-11 phosphors on fiber optic output windows.

Williams, J. T.

Ultraviolet proximity focussed converters for use in a satellite SEC-TV system.

Performance characteristics of Bendix type BX08025-4522 proximity-focussed vacuum-ultraviolet to visible-light image converters are presented. The converters are to be used with SEC vidicons as detectors for an echelle spectrograph on the International Ultraviolet Explorer astronomical satellite. Magnesium fluoride input windows with Cs-Te photocathodes are used in the converters, with P-11 phosphors on the fiber optic output windows. Quantum efficiencies, modulation transfer function, background, geometric distortion, and environmental test results are presented for the wavelength region from 1150 to 3500 A.-

Feibelman, W. A.

Combined observations of meteors by image-orthicon television camera and multi-station radar

Observations from multiple sites of a radar network and by television of 29 individual meteors from February 1969 through June 1970 are reported. Only 12 of the meteors did not appear to fragment over all the observed portion of their trajectories. From these 12, the relation for the radar magnitude to the panchromatic absolute magnitude was found in terms of velocity of the meteor. A very tentative fit to the data on the duration of long enduring echoes versus visual absolute magnitude is made. The exponential decay characteristics of the later parts of several of the light curves are pointed out as possible evidence of mutual coalescence of droplets into which the meteoroid has completely broken.

Cook, A. F.

Meteor research program

Statistics from synoptic year sample of 20,000 radar meteor observations using eight station radar network

Cook, A. F., II

Simultaneous observations by television camera and radar

The original image-orthicon equipment used for simultaneous radar and optical observations is described. The adaptations made to enhance its usefulness for meteor observations, and the specialized calibration and photometric procedures developed for this purpose are also described. Some brief comments concerning the use of the secondary electron conduction vidicon are included.

Mccrosky, R. E.