Optimization of pin bearing joint strength for segmented graphite/epoxy filament wound case in Space Shuttle
An attempt is made to demonstrate the feasibility of a composite joint in a segmented, graphite/epoxy filament-wound composite case for the Space Shuttle's Solid Rocket Motors. The joint's required ultimate line load is of the of 82,000 lb/in. By optimizing composite layup, and the ratios of pin diameter/specimen thickness, edge distance/pin diameter, and specimen width/pin diameter, a pin bearing joint strength of 85 ksi was obtained. Double pin testing disclosed that the pin close to the composite joint carries a higher load than the outboard pin. Pin bearing strength is noted to vary with matrix resin system.