Engineering Papers⌕ Search

Engineering topics

Wilkerson, Andrea

Publications and source records attributed to Wilkerson, Andrea.

At least 19 records

Why Tunable? A Look at Schools Using Tunable Lighting

Between 2016-2019, Pacific Northwest National Laboratory (PNNL), documented two early pilot installations of tunable lighting in schools, supported by U.S. Department of Energy (DOE) Solid-State Lighting (SSL) program. These pilot installations were opportunities for the schools to become more familiar with the technology, save energy, and support teachers and students. Tunable lighting continues to be of interest, particularly in classrooms for students with disabilities. This case study looks at tunable lighting systems installed in classrooms at eight school districts across the U.S. since 2015, the earliest known installation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Upgrading Linear Fluorescent Fixtures to LED in Schools

Lighting is a key component to creating a functional and high-quality learning environment for students and staff. Light-emitting diode or LED lighting fixtures have gained traction in common commercial building applications and quality replacement options for common fixture types are widely available. Compared to most fluorescent lighting systems, using LEDs can reduce energy consumption and therefore decrease carbon dioxide emissions, reduce maintenance and operation cost, and improve the visual appearance and lighting quality of the classroom and school environments. When additional controls are considered, more energy can be saved and some controls, like dimming, can offer amenities to occupants. As LEDs become an even more prominent lighting technology, fluorescent equipment may become challenging or expensive to replace. Additionally, school buildings are typically in use for many decades; maintaining a long-term view can be important when deciding which upgrade path to take. This fact sheet provides guidance on the various factors to consider when deciding on an LED upgrade for fluorescent lighting systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

TECHNOLOGY: A Lesson In LED Adoption: Understanding the hurdles faced by K–12 schools

PK-12 schools lag in upgrading fluorescent lighting. Surprised? So were we; spurring a journey to understand the reasons for lagging adoption of LED. During conversations with school facility managers and other lighting professionals the reasons became clearer. What follows is a synopsis of what has been uncovered so far, yet there remains much to learn. Here, these stories are not the product of imagination; they represent real experiences, real decisions, and real concerns from 9 school districts in 7 states from coast to coast.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparing Occupant Light Exposure in Factory and Office Spaces

There is an increasing desire to provide healthy workplace environments that better serve people while minimizing the impact on the planet. Building recommendations help designers to incorporate the latest research and best practices, but translating research studies conducted in different settings to broader recommendations is challenging. This is particularly true for lighting, with researchers continuing to learn more about circadian, neuroendocrine, and neurobehavioral responses to light. The recommendations are regularly adjusting to incorporate the latest research as well as feedback from practitioners implementing these recommendations. There remains a need to better document the actual light exposure that people experience over the course of a day and across seasons, so that researchers can better understand the influence of light on people and recommendations can be refined. Thankfully, advances in sensor technology are making this more possible than ever. PNNL collaborated with ETC Inc. to understand actual occupant light exposure in factory and office spaces at ETC’s Headquarters in Middleton, WI. The primary building at ETC headquarters opened in 2004 and houses approximately 800 employees that contribute to central business functions, customer support, research and development, as well as the company’s primary 60,000 ft2 manufacturing facility. Vertical light exposure measurements including electric light and daylight were recorded in factory, research and development, and office work areas at occupant eye height. This document will focus on lighting measurements collected in six factory and office locations across work location, season, and time of day. Ultimately, detailed lighting measurements can be coupled with employee surveys to support development of satisfactory work environments.

42 ENGINEERING↗

Studying Response to Light in Offices: A Literature Review and Pilot Study

Researchers have been exploring the influence of light on health in office settings for over two decades; however, a greater understanding of physiological responses and technology advancements are shifting the way researchers study the influence of light in realistic environments. New technologies paired with Ecological Momentary Assessments (EMAs) administered via smartphones provide ways to collect information about individual light exposure and occupant response throughout the day. The study aims to document occupant response to tunable lighting in a real office environment, including potential beneficial or adverse health and well-being effects. Twenty-three office employees agreed to participate in a twelve-week study examining occupant response to two lighting conditions (static vs. dynamic). No significant differences were observed for any of the measures, highlighting the importance and complexity of in-situ studies conducted in realistic environments. While prior office studies have shown a significant influence on daytime sleepiness and sleep quality, research has not shown mood or stress to be significantly impacted by lighting conditions. Correlation analyses regarding lighting satisfaction, environmental satisfaction, and visual comfort demonstrate a significant relationship between certain items that may inform future studies. Further, the high correlation means it is reasonable to assume that many environmental factors in offices can influence occupant behavior and well-being.

60 APPLIED LIFE SCIENCES↗

Lighting for Health and Wellness Recommendations in Offices: A Circadian Lighting Pilot Project in Chicago, IL

In 2019 Cook County initiated a request for proposals for a pilot project aimed at designing and specifying an advanced tunable lighting system for government offices in Chicago, Illinois. The primary goal of the project was to replace the existing tubular LED (TLED) lighting system with a lighting system that supported the circadian rhythms and wellbeing their office employees. A secondary goal was to evaluate the potential impacts of the new lighting system, informing Cook County’s internal workplace design standards. Schuler Shook, a Chicago-based lighting design firm, was awarded the Circadian Lighting Pilot Project in October 2019 and invited Pacific Northwest National Laboratory (PNNL) to contribute as a research partner. Based on the initial project goals, Schuler Shook and PNNL established design objectives that would enable a human factors study in the office spaces, investigating the benefits and drawbacks of using a tunable LED lighting system to meet existing recommendations for lighting and health. The following report details the lighting design process through design development, with summaries of the relevant circadian lighting metrics, simulation tools, energy considerations, and research plan for the Circadian Lighting Pilot Project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tunable White Light for Elders (TWLITE): A Protocol Demonstrating Feasibility and Acceptability for Deployment, Remote Data Collection, and Analysis of a Home-Based Lighting Intervention in Older Adults

Sleep disturbances are common in older adults and may contribute to disease progression in certain populations (e.g., Alzheimer’s disease). Light therapy is a simple and cost-effective intervention to improve sleep. Primary barriers to light therapy are: (1) poor acceptability of the use of devices, and (2) inflexibility of current devices to deliver beyond a fixed light spectrum and throughout the entirety of the day. However, dynamic, tunable lighting integrated into the native home lighting system can potentially overcome these limitations. Herein, we describe our protocol to implement a whole-home tunable lighting system installed throughout the homes of healthy older adults already enrolled in an existing study with embedded home assessment platforms (Oregon Center for Aging & Technology—ORCATECH). Within ORCATECH, continuous data on room location, activity, sleep, and general health parameters are collected at a minute-to-minute resolution over years of participation. This single-arm longitudinal protocol collected participants’ light usage in addition to ORCATECH outcome measures over a several month period before and after light installation. The protocol was implemented with four subjects living in three ORCATECH homes. Technical/usability challenges and feasibility/acceptability outcomes were explored. The successful implementation of our protocol supports the feasibility of implementing and integrating tunable whole-home lighting systems into an automated home-based assessment platform for continuous data collection of outcome variables, including long-term sleep measures. Challenges and iterative approaches are discussed. This protocol will inform the implementation of future clinical intervention trials using light therapy in patients at risk for developing Alzheimer’s disease and related conditions.

60 APPLIED LIFE SCIENCES↗

Lighting System Control Data to Improve Design and Operation: Tunable Lighting System Data from NICU Patient Rooms

The advancement of LED and controls technology, computing capacity, and software provides new opportunities for researchers and designers to work together to further optimize spaces for occupant benefit. Here, lighting system control data from five neonatal intensive care unit patient rooms was collected over a 25-week monitoring period and analyzed to better understand occupant response to a tunable lighting system with automatic transitions throughout the day. Lighting systems are very rarely refined after installation based on actual use. Objective data detailing how the lighting system is used by the actual occupants highlights the opportunities for optimization after installation and provides insight for improving the next design. As use of the data becomes more commonplace, it can be leveraged for design recommendations. The collection of the data required no additional cost beyond the time for examining the data. The analysis revealed several clear opportunities for improvement, including adjustments to the default control setting at night, re-labeling of the control stations, and adjustments to the nighttime fade rate. The patient room occupants were active users of the different zones, dimming options, and manual overrides made available by the lighting system.

60 APPLIED LIFE SCIENCES↗

Feasibility and preliminary efficacy for morning bright light therapy to improve sleep and plasma biomarkers in US Veterans with TBI. A prospective, open-label, single-arm trial

Mild traumatic brain injury (TBI) is associated with persistent sleep-wake dysfunction, including insomnia and circadian rhythm disruption, which can exacerbate functional outcomes including mood, pain, and quality of life. Present therapies to treat sleep-wake disturbances in those with TBI (e.g., cognitive behavioral therapy for insomnia) are limited by marginal efficacy, poor patient acceptability, and/or high patient/provider burden. Thus, this study aimed to assess the feasibility and preliminary efficacy of morning bright light therapy, to improve sleep in Veterans with TBI (NCT03578003). Thirty-three Veterans with history of TBI were prospectively enrolled in a single-arm, open-label intervention using a lightbox (~10,000 lux at the eye) for 60-minutes every morning for 4-weeks. Pre- and post-intervention outcomes included questionnaires related to sleep, mood, TBI, post-traumatic stress disorder (PTSD), and pain; wrist actigraphy as a proxy for objective sleep; and blood-based biomarkers related to TBI/sleep. The protocol was rated favorably by ~75% of participants, with adherence to the lightbox and actigraphy being ~87% and 97%, respectively. Post-intervention improvements were observed in self-reported symptoms related to insomnia, mood, and pain; actigraphy-derived measures of sleep; and blood-based biomarkers related to peripheral inflammatory balance. The severity of comorbid PTSD was a significant positive predictor of response to treatment. Morning bright light therapy is a feasible and acceptable intervention that shows preliminary efficacy to treat disrupted sleep in Veterans with TBI. A full-scale randomized, placebo-controlled study with longitudinal follow-up is warranted to assess the efficacy of morning bright light therapy to improve sleep, biomarkers, and other TBI related symptoms.

60 APPLIED LIFE SCIENCES↗

2022 Solid-State Lighting R&D Opportunities

This is an updated edition that examines critical opportunities to positively impact energy savings, greenhouse gas emissions, human well-being, and the economy through Solid-State Lighting (SSL) R&D. The document summarizes stakeholder input from DOE-hosted roundtable meetings, workshops, a Request for Information, and other sources.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using occupant interaction with advanced lighting systems to understand opportunities for energy optimization: Control data from a hospital NICU

For this study, lighting system control data from five patient rooms in a neonatal intensive care unit (NICU) over a 25-week monitoring period were analyzed to better understand how the NICU staff and families interacted with an automatic tunable lighting system (variable spectrum and intensity) with manual override options. The data were analyzed to determine the amount of time spent in available lighting modes, estimate energy consumption, and to observe any patterns in how the lighting system was being used by occupants. Further analysis revealed opportunities for optimizing the system for occupant needs and energy savings. The patient room occupants were clearly engaged in using the lighting system throughout the 24-hour day to meet needs and preferences. Giving occupants control over the lighting system did not result in a considerable increase in energy use. Implementing a time-out would minimize the extended periods of time when the lights were left on without need at the highest brightness level, further decreasing energy use. This analysis reveals the potential of lighting control data to contribute to energy savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy impact of human health and wellness lighting recommendations for office and classroom applications

The goal of this investigation was to evaluate potential energy impacts of circadian lighting design recommendations gaining attention in a variety of common applications such as offices and classrooms. The renewed focus on health along with advances in SSL technology capabilities has underscored that there is still much to learn regarding the relationship between light and human physiology. The energy implications of designing to address these possible physiological effects are not yet fully understood. Beyond the fact that the basic metric of luminous efficacy (lumens per watt) does not cover these other effects, the emerging science seems to indicate that addressing a holistic view of the human needs in most applications may mean a need for increased light and associated energy use by electric lighting systems. Within the two applications considered, lumen output, spectral characteristics, surface reflectance distribution and desk orientation were varied to explore the magnitude of potential effects. Meeting current IES illuminance recommendations did not satisfy existing EML and CS recommendations for any of the simulations. In some cases, satisfying circadian metric recommendations required average illuminance that was more than double IES recommendations, which may negatively impact lighting quality as well. Using results from 45 unique simulation conditions, it was estimated that lighting energy use may increase between 10% and 100% due to increased luminaire light levels used to meet circadian lighting design recommendations listed in current building standards such as WELL v2 Q2 2019, UL Design Guideline 24480, and CHPS Core Criteria 3.0.

circadian lighting, lighting simulation, solid sta↗

Lighting Control in Patient Rooms: Understanding Nurses’ Perceptions of Hospital Lighting Using Qualitative Methods

Here, this study differs in its methodological approach from previously published research by interpreting qualitative results against existing literature to understand how nurses conceptualize medical–surgical patient rooms as productive settings in relation to lighting, as well as the ways in which nurses believe these spaces could be enhanced for patient satisfaction. Content analysis was used to interpret themes emerging from nurses’ subjective responses to open-ended items. Three of the facilities had older, traditional lighting systems; one had a contemporary framework. A theme of environmental control over both overhead and task lighting emerged from data from all items. Although controllability was among the “best” lighting attributes, more refinement is necessary for optimal staff productivity and patient satisfaction. Daylighting was also considered to be among the best attributes. Control over light level via additional dimming capability for patients, as well as additional light sources, was prominent across the four hospitals. Unique to the more modern facility, trespassing of light was problematic for nurses considering the experiences of patients—even where modern models exist, more attention can be paid to the ways in which window shades, and light sources outside of rooms, penetrate spaces and affect users. Finally, the finding that nurses and patients desire greater control over the lighting in patient rooms is consistent with Ulrich’s theory of supportive design for healthcare and coincides with advances in lighting technology. Despite differences in the level of sophistication in lighting among the four facilities, control continues to be a primary concern for nurses.

60 APPLIED LIFE SCIENCES↗

Area Lighting Yuma Sector Border Patrol Area, AZ. SSL Evaluation [Brief]

Along the Yuma Sector Border Patrol Area in Yuma, Arizona, the GATEWAY program conducted a trial evaluation in which the incumbent quartz metal halide area lighting was replaced with LED at three pole locations, and illuminance measurements were recorded initially and at 2500 hours, 5000 hours, 7000, and 11,000 hours of operation. Additionally, four second-generation LED luminaires installed as part of the full installation were evaluated initially and again after 4,000 hours of operation. While the initial energy, lighting quality, and maintenance benefits relative to the incumbent high-pressure sodium system were very satisfactory, the study raises important questions regarding the long-term performance of LED lighting systems in high-temperature environments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nurses’ Satisfaction with Patient Room Lighting Conditions: A Study of Nurses in Four Hospitals with Differences in the Environment of Care

Lighting systems in patient rooms must balance energy efficiency concerns with the holistic needs of patients, families, and medical caregivers. This paper reports survey responses from 138 individuals working in medical-surgical units in four hospitals, with three of the hospitals having traditional lighting systems and the other hospital having a more contemporary lighting system. The results add to a growing evidence base on the effects of lighting on nurses’ job performance, job satisfaction, and overall perceptions of the environment, and provide evidence that innovative lighting approaches and technologies are worth considering as an investment by hospital administrators looking to improve employees’ and patients’ perceptions of the patient room environment. This knowledge is intended to help facility designers and managers incorporate nurses’ perspectives in their decisions, as well as to inform technologists and engineers developing future generations of lighting systems for patient rooms. These future systems will utilize solid-state lighting technologies, such as LEDs, and will provide new opportunities for adapting the intensity, distribution, and spectrum of light to better satisfy the holistic needs of patients and caregivers at different times of day or night.

Davis, Robert G.↗

Patient rooms transition: Contemporary makes way for the future

Recent advances in lighting research, technology and control systems are creating new opportunities to use lighting in healthcare facilities, particularly patient rooms, to improve everyday experiences for patients, visitors and staff. Healthcare facilities design has undergone shifts in thinking over the past 50 years, including the incorporation of more technology, and moving from an institutional appearance to a residential appearance, with biophilic elements. The Facilities Guidelines Institute defines the term environment of care as “those physical environment features in a health care facility that are created, structured, and maintained to support and enhance the delivery of health care”. Many attributes of the environment of care in existing hospital patient rooms, especially those built prior to 1990, reflect a focus on maximizing the efficiency of delivering medical care, sometimes without much attention to the impact of design on the experience of patients and guests.

Davis, Robert G.↗

Experimental validation of color rendition specification criteria based on ANSI/IES TM-30-18

An experiment was conducted to examine color preference specification criteria. Twenty-five participants each evaluated 90 lighting scenes in a room filled with objects. The lighting scenes included nine chromaticity groups, each with 10 systematically-varied color rendition conditions designed to meet or not meet previously proposed color preference specification criteria using ANSI/IES TM-30-18 Rf, Rcs,h1, and Rg. The color rendition conditions did not meet the criterion for none, one, two, or all three of these measures. Participants, who chromatically adapted to each chromaticity group, rated the objects’ color appearance on eight-point scales for saturated-dull, normal-shifted, and like-dislike (preference), as well as a binary for acceptable or unacceptable. The findings corroborate past work, but also indicate that color preference criteria could be adjusted slightly to improve performance, with Tier A having Rf = 78, Rg = 95, and -1% = Rcs,h1 = 15%, Tier B having Rf = 74, Rg = 92, and -7% = Rcs,h1 = 19%, and Tier C having Rf = 70, Rg = 89, -12% = Rcs,h1 = 23%. A companion regression analysis shows models based on Rf, Rg, and Rcs,h1 were superior in predicting color preference compared to those using other measures of color rendition.

Royer, Michael P.↗