Engineering Papers⌕ Search

Engineering topics

Wilcox, Floyd J., Jr.

Publications and source records attributed to Wilcox, Floyd J., Jr..

21 records · Page 2

Unexpected/expected results from the Langley 20-Inch Supersonic Wind Tunnel during initial checkout

NASA Langley's 20-Inch Supersonic Wind Tunnel is currently undergoing shakedown tests. The facility operates over the supersonic Mach number range of 1.4 to 5.0 with Reynolds number per foot variation of approximately 500,000 to 20 million. Checkout runs have been conducted at Mach numbers of 1.4, 2.8, and 5.0 over the entire operational mass flow and total pressure envelope. Data were recorded for total temperature characteristics, Rigimesh pressure drop characteristics, and for the switching exhaust system. Data recorded and observations made during checkout are discussed.

Dillon, James L.↗

Drag measurements of blunt stores tangentially mounted on a flat plate at supersonic speeds

An investigation has been conducted in the Langley Unitary Plan Wind Tunnel to measure the drag of blunt stores (hemispherical noses and afterbodies) tangentially mounted in various arrays on a flat plate at nominal Mach numbers of 1.60, 1.90, 2.16,and 2.86 and at a nominal Reynolds number of 2X10 to the 6th power per foot. The arrays consisted of two and three stores mounted in lateral, tandem, or staggered arrangements. The relative position of the stores in the arrays was varied while the drag of only one store was measured to determine the effect of spacing on the store drag. Store-on-store interference was determined by comparing the drag of a single store with the drag of the store in an array. The results indicate virtually all arrangements and spacings which were tested had favorable store-on-store interference (drag reduction) across the Mach number range. Tabulated data, schlieren photographs, and shadowgraphs are included.

Wilcox, Floyd J., Jr.↗

Experimental cavity pressure distributions at supersonic speeds

An investigation was conducted to define pressure distributions for rectangular cavities over a range of free-stream Mach numbers and cavity dimensions. These pressure distributions together with schlieren photographs are used to define the critical values of cavity length-to-depth ratio that separate open type cavity flows from closed type cavity flows. For closed type cavity flow, the shear layer expands over the cavity leading edge and impinges on the cavity floor, whereas for open type cavity flow, the shear layer bridges the cavity. The tests were conducted by using a flat-plate model permitting the cavity length to be remotely varied from 0.5 to 12 in. Cavity depths and widths were varied from 0.5 to 2.5 in. The flat-plate boundary layer approaching the cavity was turbulent and had a thickness of approximately 0.2 in. at the cavity front face for the range of test Mach numbers from 1.5 to 2.86. Presented are a discussion of the results and a complete tabulation of the experimental data.

Stallings, Robert L., Jr.↗